1) voltage motion of generatrix
母线电压波动
2) DC-link ripple
直流母线电压波动
1.
In order to improve the line-to-line voltage quality of three-phase three-level inverter with H bridges,the phenomenon of DC-link ripples and the neighboring layer overlapping of line-to-line voltage are analyzed theoretically.
为改善传统三相H桥三电平逆变器输出线电压质量,对存在的直流母线电压波动和线电压相邻"电平层"交叠现象进行理论分析。
3) busbar voltage
母线电压
1.
In order to address the problems of the alarm setting value of the direct-current equipment in current transformer substations, this paper analyzes the checking charge-discharge results of the batteries and then proposes recommendable values of the direct-current busbar voltage alarming value,so as to offer help to the safe and reliable operation and the maintenance of the direct current system.
通过对目前变电站直流设备报警整定值存在的问题,通过对蓄电池核对性充放电结果的分析,提出了直流母线电压报警值的推荐值,希望对直流系统的安全稳定运行,对直流系统维护提供帮助。
2.
According to the principle of backup power switchover unit of LFP-965, LFP-965 unit can not distinguish two buses without voltage synchronously when public busbar voltage transformer and line voltage transformer are employed at the same time.
根据LFP-965型备用电源自动投入装置的工作原理,分析了在一些电气主接线方式为内桥型接线的变电站中,当母线电压互感器(PT)与线路PT共用时,由于LFP965型备用电源自动投入装置不能判别两段母线是否同时失压,从而限制了其使用范围。
3.
This article introduces an event about protection action causing by the decrease of busbar voltage in Xiaolangdi hydropower station, in order to make people pay attention to voltage management to ensure the safety and stability of power grid and generating units.
对小浪底一起母线电压降低导致保护动作实例进行分析研究,以引起对电压管理的重视,从而确保机组、电网的安全运行。
4) bus voltage
母线电压
1.
We proposed a new method to distinguish the lightning strikes and common short-circuit faults on the basis of the characteristic of the bus voltage signals using S-transform.
基于行波特征区分雷电冲击与短路故障有一定局限性,提出一种利用母线电压信号特征识别雷击与短路故障的新方法。
2.
There are several factors leading to relatively low measured value of bus voltage,so the cause analysis and elimination are necessary.
引起母线电压测量值偏低的原因有多个,必须逐一进行分析排查。
5) variable bus voltage
变母线电压
6) voltage drop of electric network bus
电网母线电压降
补充资料:电压波动和电压闪变抑制
电压波动和电压闪变抑制
suppression of voltage fluctuation and flicker
d ianyabodong he dianyashan bion yizhi电压波动和电压闪变抑制(suppression。fvoltage fluetuation and flieker)冶金工厂中的电弧炉、大电动机、大电焊机等工作时,负荷电流的大幅度增减,引起电压急剧变化,其变化速度大于每秒。.2%,此时出现电压调幅波中的最高电压与最低电玉均方根值之差,称为电压波动。电压波动和有时伴随产生的电压闪变导致用电设备运行不稳定,照明闪烁,影响正常生产、生活甚至人身健康。因此,须对电压波动和闪变进行抑制,使其控制在允许范围内。 在中国按国家标准(GB12326一90)规定,电力系统公共供电点的电压波动允许值为:10kV及以下为2.5%,35~110kV为2.0%,220kV及以上为1.6%。在冶金工厂内部(非公共供电点),按本行业的有关规定,当电弧炉和轧钢大电动机由单独变压器供电时,其用电电压波动允许值可放宽到5%以内。 在电弧炉的熔化期,冲击性无功负荷产生快速的电压波动,使照明灯光发生闪烁,引起人的视觉疲劳而使情绪烦燥,还可能导致电视荧屏监控图像不稳、精密电子仪器工作不正常等。此种人的眼睛对于灯闪的主观感觉称为闪变。对闪变的程度,以对人的眼睛最为敏感的loHz频谱的等效闪变电压值△V10的大小来衡量和评价,按国家标准(GB12326一90)规定,电力系统公共供电点的允许△V10推荐值为:照明要求较高的白炽灯负荷为0.4%,一般性照明负荷为。,6%。 其抑制措施是:(l)对于轧机主传动的冲击性负荷,设计时采用减少电网感抗,以提高供电点的短路容量;或利用自备发电厂发电机,大型同步电动机(如高炉电动鼓风机)进行跟踪补偿;或将两个以上的冲击负荷在时间上错开;或设立单独的静止型动态无功补偿器等加以解决。后者有晶闸管开关电容器式(TSC)、晶闸管控制电抗器式(TCR)、晶闸管控制高阻抗变压器式(TCT)、自饱和电抗器式(SSR)、可控饱和电抗器式(CSR)、复合式(TCR十TSC)和自激变换器式(SVG)等多种类型。(2)对于电弧炉冲击性负荷,设计时采用减少电网感抗以提高供电点的短路容量;或设置单独的静止型动态无功补偿器等加以解决。由于电弧炉在熔化期三相负荷经常不平衡,闪变剧烈,要分相进行控制。要求补偿器响应速度快(全过程的响应时间应小于1个周波)参设计通常采用TCR、SSR、TCT和TCR二TSC等几种静止型动态无功补偿器。 (张炳炎)
说明:补充资料仅用于学习参考,请勿用于其它任何用途。