1)  3D grounding grid
立体接地网
1.
To reduce the grounding resistance of substations in p erennial frozen sediment soil of Qinghai-Tibet plateau, The 3D grounding grid i s studied.
针对格拉段经过青藏高原高土壤电阻率的多年冻土地区,提出了铁路沿线变电站采用立体接地网降低接地电阻,并从地网面积、地网中垂直接地体及季节变化等的影响分析了立体地网在冻土地区的接地降阻效果。
2)  three dimensional grid
立体地网
3)  twisted cube connected network
扭立方体连接网络
1.
In this paper, based on the routing algorithm presented in [1],the broadcasting algorithms in the twisted cube connected networks are presented for the single port and the multi port I/O models.
根据文献 [1 ]中给出的路由算法 ,提出了单端口 I/O与多端口 I/O两种模型下扭立方体连接网络上的广播算法 ,并证明了这些算法是广播步数最小的算法 。
2.
In this paper, based on the recursive property, it is proved that there are k binomial tree subgraphs in the twisted cube connected network, that is, k binomial trees can be embedded into the twisted cube connected network with dilation 1, congestion 1 and load 1 (0≤ k≤n ).
根据扭立方体连接网络结构的递归性 ,证明了 n维扭立方体连接网络中存在以任意顶点为根结点的k阶二项树子图 ,也就是说 k阶二项树可以最小的扩张、拥塞度和负载嵌入到 n维扭立方体连接网络中 ( 0≤ k≤n
3.
Based on the recursive property of twisted cube connected networks, this paper studies the problem of embedding the hypercube into the twisted cube connected network.
扭立方体连接网络是超立方体的一个变种,它具有良好的结构递归性和较理想的网络参数。
4)  3-D grounding device
三维立体接地装置
1.
Vertical ground system of the 3-D grounding device, which is a combination of traditional horizontal ground grid and vertical ground electrode, can effectively solve the over-valued tower grounding resistance problem in rocky geology.
三维立体接地装置垂直接地体是一种用传统的水平接地网与垂直接地极相结合构成的三维立体接地装置,可以有效地解决岩石地质塔位接地电阻值过高的问题。
5)  independent grounding
独立接地
1.
With respect to the problem of whether use independent grounding or common grounding for DCS, the discussion was carried out in this article.
针对DCS应该采用独立接地还是采用共用接地系统作了讨论。
2.
With the increasing of the diversification and quantity of load equipments in low-voltage electric power supply distribution system, it becomes a question as whether an electric equipment should be independent grounding or shared grounding.
随着低压供配电系统中的负荷设备种类的多样化和数量的日益增长,各种电气设备的接地是分开独立接地,还是共用接地,已成为广大设计工作者十分关心的问题。
6)  three-dimensional network
立体联网
1.
Ideal of three-dimensional network based on urban expressing system and traffic railway in Qingdao;
青岛轨道交通与快速路系统立体联网的构想
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。