1) resonance overvoltage in non-full phase operation
非全相谐振过电压
2) resonant overvoltage
谐振过电压
1.
In the light of the analysis of the resonant overvoltage ,the causes of resonant overvoltage are found out ,and the methods to solve the problems are put forward,to ensure the safety and reliable operation of the power System.
通过对谐振过电压的分析,找出了谐振过电压的原因,提出了解决问题的方法,保证了电力系统的安全可靠运行。
2.
The RTDS was used to analyze and calculate the resonant overvoltage occurred during start-up debugging of 500 kV Ganshan-shuangsi double-circuit lines on the same tower,and the hidden troubles in various operational modes are studied.
应用实时数字仿真系统(RTDS)对500 kV阚山—双泗同塔双回线路启动调试中发生的异常谐振过电压进行了全面细致的仿真计算研究,列举了各种工况的仿真结果,对谐振原理进行了分析,对实际运行系统可能出现的各种运行方式所存在的安全隐患作了分析研究,提出了切合实际和可行的运行方案及建议。
3) resonance overvoltage
谐振过电压
1.
With the understanding of the generation of the resonant overvoltage and ferromagnetic resonance overvoltage limit,lightning arrester and the HXB arc-resonance extinguishing overvoltage protection installment are proposed to use.
了解谐振过电压的产生与对铁磁谐振过电压限制,建议采用避雷器与HXB型消弧及消谐过电压保护装置。
2.
As for the 1000kV AC pilot project in China, it is possible to appear resonance overvoltage with higher amplitude caused by energizing no-load transformers.
研究了我国1000kV特高压试验示范工程中可能出现幅值较高的合空载变压器谐振过电压现象,阐述了合空载变压器谐振过电压的机理与影响因素及其对策。
4) resonant over-voltage
谐振过电压
1.
This paper, from the technological perspective, analyzes the causes of displacement over-voltage of neutral points, break-line over-voltage, iron magnetic resonant over-voltage & arc over-voltage, and proposes more than two technical solutions to these problems.
本文首先从技术角度分析中性点位移过电压、断线过电压、铁磁谐振过电压和弧光过电压产生的原因 ,然后提出两种解决以上问题的技术措施 。
2.
Based on the parameters of the circuit composed of single-phase, three-phase inductors and capacitors, the resonant conditions when both serial and shunt constructed were analyzed, and the reason why the resonant over-voltage occurred in 6 kV system was proposed, along with its prevention and dealing methods.
基于单相及三相电感、电容组成的线路参数,分析了串联及并联时的谐振条件,得出6kV系统谐振过电压产生的原因。
5) overvoltage of harmonic resonance
谐波谐振过电压
6) ferroresonance overvoltage
铁磁谐振过电压
1.
This paper analyzes the generation mechanism of ferroresonance overvoltage in low and medium voltage electrical network, and probes into the advantages and disadvantages of currently adopted elimination measures.
分析了中低压电网铁磁谐振过电压的发生机理,探讨了目前采用的消谐措施的优缺点。
2.
So, it has great significance to research ferroresonance overvoltage.
相对于中性点非直接接地系统而言,发生在中性点直接接地系统中的铁磁谐振过电压有着许多新的特点,而且对它的研究相对较少。
3.
In recent years, the problems in traction power supply system, such as ferroresonance overvoltage, overvoltage of the split phase, the rail voltage raise and the integrated earth wire etc.
近几年,我国高速重载铁路牵引供电系统出现了铁磁谐振过电压、分相过电压、钢轨电位升高和综合贯通地线等问题,这些问题理论研究还不够深入,在工程上还没有得到很好地解决,它们随时威胁着电气设备绝缘、通信信号设备稳定和牵引供电系统和机车(动车)的安全,研究这些过电压的形成机理和防护方法对促进我国高速重载铁路的发展具有重要的意义。
补充资料:电力系统非全相运行过电压
电力系统非全相运行过电压
overvoltage in open phase operation in electric power system
相开断的结果使得回路接近于谐振状态.如果TK<(C。+ZC::)/(C。+3C,:),且如乙>1/[。(C。+ZC::)〕,则单相开断后可能激发起工频铁磁谐振.这些情况都会在被开断相上产生很高的恢复电压,使得电弧不能自熄,导致断路器的重合失败.为此,如在相间并接电感Ll:(见图2),使得毗!:~1/(‘12),以形成并联谐振,阻塞了相间联系,非全相铁磁谐振就可被抑制.此时,图2中的零序电感大于正序电感,故实际上可通过在电抗器中性点上接入附加电感L、来达到目的。令L。为电,器本身的二序电感,则有LN。一L。+3LN,会 1 .3 1.-。~1..一=丫‘+资~;一,立二丫+3扩cl:,由此得LN二 LN。’L一2 Lo+3乙N·一一:‘,二~,一。1 F TXL,飞~了L于哥二万石一‘。」’‘。一3ClzCo十3C12ToL。三个单相电抗器组的L~L。,故LN~3(TK一To)。在拾电线路计划性合闸的第一阶段或计划性分闸┌───┬───┐│不孤妞│少《/ ││)乙” │ L.o │└───┴───┘图2并接相间电感后 的接线图的第二阶段,导线处于单侧供电下的空载状态,如断路器分相拒动或不同期动作,将会形成与上述相仿的谐振回路,附加电感L。可以同样起到消除谐振的作用。 当采用可控电抗器时,将其中性点不接地或者采取三角形接线方式,则当发生上述非全相运行状态时,快速调节三相电抗器的容t。使其相间感抗等于毗1:二1/(‘,:),谐振即可消除,井使潜供电流和恢复电压下降到容许数值以下。d}an}lx}tong telquonxlong yonx}ngg日od}onyo电j7系统非全相运行过电压(overvoltage inoPen phase operation in eleetrie power system) 电力系统在非全相运行条件下产生的铁磁谐振过电压。造成非全相运行的原因,是断路器的分相切合、分相拒动和三相触头间的不同期动作,以及高压熔断器的分相熔断和不对称分合操作等。 非全相运行过电压与断线谐振过电压的性质基本相同,区别在于非全相运行的断线点发生在断路器或熔断器处,非全相运行的谐振回路中不存在接地故障。 超高压长线路中普遍设置并联电杭器.其单相重合闸过程也是一种非全相运行方式,当单相(a相)开断和潜供电弧熄灭后,健全相通过对被开断相的相间的电容c,2而形成静电分盘的传递谐振回路,如图1所示。图中忽略了导线电感和电源漏抗,L为三相电抗器的正序电感,LN为电抗器中性点的附加电感,C。为导线的对地电容,U、和U。为健全相电压,电h丫二est峨,一一.图1单相开断后的传递谐振回路抗器的补偿度为TK~1/【扩L(c。+3CI:)〕。在LN~o时,谐振条件为毗~1/〔州C。+Zc:2)〕,或者TK二(C0+ZC12)/(C。+sC,2)。通常采取TK<1,故单
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条