1) re-heater
再热器管
1.
Tubing leakage occurred of a re-heater at Fushun power plant,the relevant case analysis results showed that the leakage was induced by corrosion of the solved oxygen in the water under scale on the tube surface,which then resulted in thinning of the tubing wall and finally in perforation of the tubes.
采用化学分析、金相分析,扫描电子显微镜等手段对抚顺发电有限责任公司2号炉低温再热器管泄漏原因进行了分析。
3) small diameter tube of reheater
再热器小径管
4) high-temperatue superheater tubes
中温再热器管
5) boiler re-heater tube
锅炉再热器管
6) reheater tube leakage
再热器管泄漏
1.
Analysis and solution of reheater tube leakage in boiler No.5 in Shajiao A Power Plant;
沙角A电厂5号锅炉再热器管泄漏原因分析及处理
补充资料:X线管热容量
X线管热容量
放射学术语。X线管允许的最大负荷量。工作时,X线管两极之间要承受极高的电压,并通过一定量电流,高速电子束撞击阳极靶面,将产生大量热能。若超过X线管允许的限度,可导致靶面熔化,造成X线管损坏。X线管的热容量受X线管结构、使用方式及设备总体性能的限制,与曝光时间、管电流、电压、焦点面积及整流方式等有关。