After analyzing the cause of tripping speed retaining unchangeable when adjusting fly ball during over-speed test, it is believed that this tripping speed is not fly ball actuated, it is another cause of the fault of speed governor, which makes opening of additional oil port in advance.
对超速试验时紧调危急保安器飞锤动作转速不变化的原因进行了分析 ,认为该动作转速非飞锤动作转速而是调速器故障造成附加油口提前打开所致 ,通过更换调速器解决了问题 ,保证了机组的安全运行。
4)  overspeed test
超速试验
1.
According to the high speed and low load charater of turbine expansion impeller overspeed tester,two design methods of high speed transmission are described.
根据透平膨胀机叶轮超速试验装置高速、轻载的特征 ,本文介绍了二种高速级传动设计的方
2.
Overspeed test is one of the important processes before the commission of a steam-power plant.
超速试验是火力发电机组投入运行前的重要工艺环节之一。
5)  Super Speed Tester
超速试验机
6)  ultra-fast speed of rotation test
超转速试验
补充资料:超速


超速
over speed

  Ch00SU超速(over speed)发电机突然甩负荷或其他原因使机组转速飞升达到超速保护动作值。转速超过汽轮机超速保护动作值仍继续飞升的称严重超速。超速保护定值为额定转速的In写士1%.附加超速保护定值为额定转速的112%~115%。机组超速表明汽枪机调节系统有故障。严重超速可造成机组损坏。 超速原因发电机甩负荷,汽轮机调节汽门未能及时关闭或关闭不严,均可引起超速。在机组具有超速隐患的条件下,若超速保护或主汽门拒动,任一因素均可造成机组的严重超速.燕汽从抽汽逆止门倒流人汽轮机内也可引起机组超速或严重超速。调节、保安系统设计或调整不当,调节、保安部套卡涩,汽门严密性差以及运行人员误操作等是造成调节、保安系统工作不正常,引起机组超速或严重超速的主要因素.防止超速措施主要有:①认真进行调节、保安系统各项常规试验,机组大修后应进行调节系统静态试验,新机组投产后要求进行调节系统动态特性试验,运行中应进行汽门活动试验以及危急保安器试验,定期检查汽门的严密性;②合理调整和整定调节、保安系统各项定值,③加强蒸汽品质的监督,防止燕汽带盐使汽门门杆结垢,油中带水使调节、保安部套锈蚀卡涩;④加强检修、运行的维护管理和人员的培训工作;⑤解列发电机时最好采用先手动脱扣,确认发电机电流倒送,再解列发电机,以避免由于汽门不严或卡涩造成机组超速或严重超速。
  