说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 变结构系统短路故障
1)  Short-circuit Faults in Power Systems with Variable Configurations
变结构系统短路故障
2)  short circuit fault of power systems
电力系统短路故障
3)  short circuit malfunction
短路故障
1.
Automatic diagnosis system for monitoring short circuit malfunction of electric net in oilfield;
油田电网短路故障诊断系统
4)  short-circuit fault
短路故障
1.
Research on overvoltage output of SPWM inverter after short-circuit fault disappears in a short time;
短路故障消除后SPWM逆变器输出过压问题研究
2.
The mathematical model for the short-circuit fault analysis and the realization of the program is discussed.
阐述了电力系统短路电流计算的原理,讨论了电力系统短路故障分析的数学模型及程序实现方法,并在分析短路电流计算原理的基础上通过可视化软件MATLAB建立了短路故障的模型,实现了其程序编制。
3.
The current signals caused by lightning strike without any fault or with fault and by common short-circuit fault are analyzed,and the characteristics are obtained: firstly,energy distributions of all frequency bands are differ.
在现有行波测距装置的基础上,提出线路受雷击和出现短路故障的识别新方法。
5)  short circuit fault
短路故障
1.
The performance of STATCOM using optimal controller at short circuit fault and load step is compared with its performance when PI controller is adopted,and its affection to the voltage and reactive power is analyzed through simulation.
通过数字仿真,对比分析了STATCOM分别采用最优控制与传统PI控制时,在电网发生短路故障和负载阶跃工况下的性能,着重分析了其对电压和无功的影响。
2.
With increase of the capacity of power system,transformer faults caused by short circuit fault occurred now and then.
220kV变压器通常采用部分接地方式,因系统容量增加,短路故障引发变压器故障时有发生。
6)  short circuit
短路故障
1.
In view of the trouble that short circuit occurred frequently in 110kV transfer substation,the method that uses change of 10kV side current of the main transfer substation to calculate the current of short circuit and infer accurate trouble point position and remove the trouble rapidly has been found out in practice to recover power supply.
针对天铁110kV变电站频繁发生短路故障问题,实践中摸索出根据主变10kV侧电流的变化,计算短路故障电流,准确推断故障点位置的方法,迅速排除故障恢复正常供电。
2.
On MATLAB simulation flat,after introducing the basic components,we can get ideal simulation results by designing,simulating and analyzing short circuit fault of a simple power system transmission line.
SimPowerSystems是专门为电力系统设计的仿真分析软件,在对其基本元件进行介绍后,在仿真平台上,通过对一个简单的电力系统输电线路的短路故障进行设计、仿真、分析,得到了理想的仿真效果。
补充资料:换流站逆变侧交流系统故障


换流站逆变侧交流系统故障
AC system faults on inverter side of converer station

  huanl一uZhonn{b一oneeJ一00!旧xltong guZhong换流站逆变侧交流系统故阵(AC systemfaults on inverter side of eonverter station)直流抽电受端交流系统发生的故障,包括三相短路、两相短路、两相对地短路、单相对地短路以及断线等.在常规的直流物电系统中,逆变器必须在受端交流系统提供的换相电压支持下才能正常工作。交流电网的故障会使逆变站交流母线电压的幅值、相位和波形发生变化,这些变化将可能引起逆变侧控制系统失去同步基准信号、阀触发系统储能不足,或逆变器的换相失败(见换流莽故降).逆变侧交流系统故障对直流系统的形响比整流侧的严重,其形响的程度往往以是否引发逆变器的换相失败或换相失败后是否能自行恢复正常来衡t。 三相对称故瘫,将由于故障地点的远近不同而使换相母线电压的下降程度不同,通常下降至额定电压的70%~60%时,逆变器就可能发生换相失败。由换相电流关系式可推导出三相交流电压下降造成逆变器发生换相失败的极限下降系数,即护万v[eos下。一eos(7。一y。。+600)〕式中。岛为换相电抗;几为直流运行电流,y。为关断角整定值;ym.二为极限关断角;U为故障前交流母线线电压有效值。如果采用低压限流(VDCL)的措施.通常在额定电压的40%时,还可维持直流系统运行。 交流系统不对称故障会使逆变站交流母线各相电压幅值和相位发生不同程度的变化。不对称故障除了降低换相电压外,还引起换相电压过零点的不对称移动,从而又直接影响到换流阀的关断角。通常不对称故障对关断角的影响比对称故障更严重。当逆变侧交流系统发生不对称故障时,逆变器往往会由于关断角变小而发生换相失败。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条