说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 直流偏场
1)  static bias field
直流偏场
1.
Stripe-to-bubble transition(SBT) of the first kind of dumbbell domains subjected to both static bias field and in-plane field is studied experimentally.
实验研究了直流偏场和面内场共同作用第Ⅰ类哑铃畴(IDs)的条泡转变现象。
2.
The softening process of the first kind of dumbbell domains (IDs) in garnet bubble films subjected to an in-plane field H_(ip) at different static bias field H_b was studied experimentally.
研究了直流偏场和面内场联合作用下,液相外延石榴石磁泡膜中第Ⅰ类哑铃畴(ID)畴壁中垂直布洛赫线(VBL)的稳定性。
3.
Annihilation procession of verticl Bloch line chains in the first kind of dumbbell domain wall subjected to both static bias field and in plane field was investigated experimentally.
研究了直流偏场和面内场联合作用下第 类哑铃畴畴壁中 VBL链的消失 ,即软化过程 。
2)  DC bias magnetic field
直流偏置磁场
1.
The dependence of the output displacement of the actuator on AC driving magnetic field frequency and DC bias magnetic field is investigated.
0μm,同时输出位移波形随频率也有明显变化;直流偏置磁场对输出位移的影响规律随工作频率不同而不同;基于叠层复合Terfenol-D的驱动器的涡流损耗较基于块状Terfenol-D的驱动器的涡流损耗大大降低。
3)  offset [英]['ɔfset]  [美]['ɔf'sɛt]
直流偏移
1.
The Uncertainty of Evaluation of DC Gain and Offset;
直流增益和直流偏移的不确定度
2.
In this paper,it is described that the uncertainty of evaluation results of DC gain and offset of linear measurement system by using the terminal-based straight line method,including the courses of analysis and evaluation of uncertainty.
介绍了用端基直线法评价线性测量系统直流增益和直流偏移指标时,测量结果的不确定度,包含了测量结果的不确定度分析和评价过程。
3.
In this paper,it is described that the uncertainty of evaluation results of both DC gain and offset of the signal processing circuits of laser doppler velocimeters(LDV),which is by using the least mean square method.
介绍了用最小二乘法评价外差式激光测振仪信号处理电路直流增益和直流偏移指标时,测量结果的不确定度分析和评定过程。
4)  DC bias
直流偏压
1.
The dielectric nonlinearity of the PMN-PZN-PT relaxor ferroelectric ceramics under DC bias was investigated.
在一定温度范围内,对PMN-PZN-PT系弛豫铁电陶瓷直流偏压下的介电非线性进行了研究。
2.
The DC bias field dependence characteristics of the PMN-PZN-PT relaxor ferroelectric ceramics were investigated.
对PMN-PZN-PT系弛豫铁电陶瓷的直流偏压特性进行了研究,直流偏压使介电常数的最大值εmax下降,介电常数最大值对应的温度Tmax升高,频率色散受到压抑。
5)  DC bias
直流偏磁
1.
Research on Dc Biased Transformers Caused by HVDC or Geomagnetic Storm;
直流输电和磁暴引起变压器直流偏磁的相关研究
2.
Calculation and study for three-phase DC bias of converter transformer
换流变压器三相直流偏磁的计算研究
3.
Study of vibration of transformers under DC bias
变压器直流偏磁的振动特性研究
6)  DC biasing
直流偏磁
1.
DC biasing can cause transformers noise increasing,vibration intensified,local overheating and even damaged.
直流偏磁会导致变压器噪音增大、振动加剧,可能引起变压器局部过热甚至损坏。
2.
The enormous ground return current caused by HVDC (high voltage direct current) system s mono-pole ground return operation mode will result in the main transformer DC biasing at the substations near the ground electrode, thus it has disadvantageous effect on AC (alternative current) system.
高压直流输电系统单极大地回线方式运行时,巨大的入地电流将会使接地极附近的变电站主变压器产生直流偏磁,对交流系统造成不利影响。
3.
The mechanism of DC biasing for output transformer of SPWM switching converter was analyzed.
分析了SPWM开关型变换器中输出变压器产生直流偏磁的机理。
补充资料:换流站直流开关场故障


换流站直流开关场故障
faults in the DC switch yard of converter station

huonlluzhan zh一l一u ko一guonehong guzhong换流站直流开关场故阵(faults in the】X二switeh yard of eonverter station)主要指发生在换流站直流开关场范围内的故库.即从换流器高压端出口至直流线路隔离开关,低压端包括至接地极之间的所有设备或连线的故障。主要包括的设备有平波电扰器、直流滤波器、中性母线、接地极引线、直流断路器和隔离开关,以及直流场内通信滤波装t和直流电流、电压测量装置等。 直流开关场内的高压侧较多发生的是设备支柱绝缘子对地闪络故障,这将引起直流电流瞬时急剧增大,是换流站较严重的故障。当发生故障时,相应的保护动作使直流系统停运。 直流开关场内的低压侧,通常发生的是中性母线或接地极引线对地短路或断线故障。如果发生对地短路故障,直流电流将流过站内接地网,造成站内接地网电位升高,使换流变压器中性接地点流人直流电流,引起直流偏磁增大而产生饱和。如果发生开路故障,则直流电流将中断,并使中性母线设备承受很大的过电压应力。 直流开关场中的设备故障主要指直流滤波器、平波电抗器的故障.直流滤波器可能发生内部短路故障、元部件的过负荷造成元件过热,或者由于支路内电容器元件的损坏数量达到一定程度后而导致电容器组件内的其它电容器元件雪崩式损坏。油浸式平波电抗器故障与变压器故障基本相同。空气绝缘的平波电抗器通常会由于绝缘设计强度或制造工艺问题而引起内部绕组局部发热而损坏。这些故障直接威胁直流系统的设备安全,都将由控制或保护动作而使直流系统停运。直流开关场的开关设备中,比较特殊的是金属回路转换断路器(MRTB)和金属回路转换开关(MRTS)。直流系统在从大地回路运行方式转换为金属回路运行方式时,MRTB需要切断的电流值约达运行直流电流的80%~90%。如果转换不成功,则MRTB必须要经受数百毫秒间隔的拉断电弧的时间,然后才能得到保护发出的重合命令,以避免MRTB的损坏。当系统中发生某些特殊不正常工况时,如大地回路运行而一端接地极损坏或接地极引线断开,同时该端中性母线接地刀闸又闭合时,则可能会有大电流流过站内接地网,造成地网损坏。为避免这种情况的发生,也配备有专门的保护。 对于双极直流输电系统,直流开关场内的大部分故障是由于单极设备的原因引起,只对单极的运行产生影响。但在直流开关场的中性线侧,有一段双极共用的中性母线,发生在该处的对地短路故障或开路故障,将直接影响双极的运行,甚至导致双极停运.直流控制保护系统通常双重化配置,如果双通道的故障切换逻辑失灵,将导致因控制系统全部失去而使直流系统停运。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条