1) OPGW installment
OPGW安装
1.
The OPGW installment technology is based on IEEE 1138 1994,IEEE 542 1992 standard and rules made by electric department.
光纤复合架空地线 (OPGW)安装技术的依据是 IEEE1138- 1994、IEEE5 2 4 - 1992等标准及电力部门对架空线安装技术的相关规定 ;笔者根据自己的施工经验 ,以大量的图片和表格阐明 OPGW安装的主要机械、安装场地的准备、OPGW及金具附件储运和现场验收、安全培训等工作要领 ,尤其对 OPGW安装过程中的牵引展放、紧线与弧垂观测、各类金具附件的安装、不锈钢管光纤单元端面处理和接头盒安放等操作技术作了重点介绍。
2) OPGW
OPGW光缆
1.
The selection of OPGW of 220 kV overhead transmission line is studied based on the specific requirement of electric power system.
根据电力系统的具体要求,研究了220 kV架空线路OPGW光缆的选择,提出了一些指导性的设计原则,其中包括短路电流、温度、截面与直径、材料、抗拉强度等选择原则。
2.
According to different types of OPGW,compare the performance of metallic optica l unit and spiral space optical unit from following parameters: hydrogen effects ,water cracking,corrosion resistance,high temperature tolerance during fault conditions,low temperature and bending performance,crush resistance,ease of s plicing procedure.
针对不同结构类型的光纤复合架空地线(OPGW)光缆,从抗"氢损"、耐水解、抗腐蚀、短路时耐高温、低温和弯曲性能、抗侧压、光缆接续等七个方面,对OPGW光缆中金属管和螺旋塑料管这两类光单元结构的性能,进行分析和比较。
3) OPGW Cable
OPGW光缆
1.
The design of the “Tian Lu” electric power line OPGW cable;
湖北“天—路”线OPGW光缆设计
4) steel tube OPGW
钢管OPGW
1.
Analysis and comparison of steel tube OPGW and aluminum cladding steel tube OPGW;
钢管和铝包钢管OPGW的分析比较
5) OPGW structure
OPGW结构
1.
Method of reasonable selection of OPGW structure to improve its ability against lightning-stroke was provided so as to reduce the probability of strand-broken due to the lightning-stroke.
介绍了雷击时影响OPGW断股的主要因素,总结了设计OPGW结构图的要点,提出当前为减少OPGW遭雷击断股的概率,应从设计角度出发合理选择其结构来提高耐雷性能的常用措施。
6) OPGW be broken
OPGW断股