1) traffic impedance values
交通阻抗值
2) traffic impedance
交通阻抗
1.
Queuing Theory Method for Traffic Impedance Analysis;
道路交通阻抗的排队论分析方法
2.
This article intervention study in the traffic impedance of urban road sections and intersections, and established a relatively detailed structure of impedance function.
本文通过对城市道路路段和交叉口交通阻抗的研究,建立了相对符合实际的阻抗函数结构;并运用图与网络理论的研究方法,分析了路网交通流特性,揭示路网点、线、面交通流特性之间的动态联系。
3.
The line in the road network diagram and its traffic impedance are defined,the method to forecast line\'s traffic impedance with real-time traffic data is introduced,and the regional and gradational algorithm of the dynamic optimal driving path is set forth and illustrated.
结合自适应信号控制系统和Internet的路由策略研究了动态行车路径算法,定义了路网结构图中的连线及其交通阻抗,介绍了根据实时交通数据预测连线交通阻抗的方法,提出并举例说明了分区分层的动态最优行车路径算法。
3) traffic impedance function
交通阻抗函数
4) minimal traffic impedance
最小交通阻抗
1.
Taking passengers trip psychology into account,an optimal path algorithm for public transit trip based on the spatial analytic functions of GIS and minimal traffic impedance was put forward to improve the deficiency of conventional algorithms.
分析了现有公交出行最佳路径算法,并针对现有算法不完善的地方,根据乘客的出行心理,利用G IS的空间分析功能,提出了一种基于最小交通阻抗的公交出行最佳路径算法。
5) value of acoustic impedance of ore
波阻抗值
6) equivalent impedance
等值阻抗
1.
Presently in transformer model,it is considered mainly whether the equivalent impedance is assigned to the side of normal ratio,but seldom whether the equivalent impedance is on the side of on-load tap changer.
目前广泛使用的理想变压器串联一个恒定等值阻抗的变压器模型,一般只以等值阻抗是否位于变压器标准变比侧来区分,而没有考虑等值阻抗是位于可调分接头侧还是位于固定抽头侧的问题。
2.
To research the accuracy of the load model and its parameters being adopted in the dispatching department of central China power grid to guide the load modeling scientifically, the equivalent impedances of distribution networks of central China power grid are calculated by power system analysis software package (PSASP).
为探讨目前华中电网调度部门实际使用的负荷模型及其参数的准确性,指导科学建模工作,利用电力系统分析综合程序PSASP计算了华中电网各配电网的等值阻抗,仿真结果表明目前应用的等值负荷模型参数与实际情况有一定差距,配电网络结构、运行电压、等值阻抗处理方法等因素对负荷模型等值的准确性均有影响,利用仿真得到的负荷模型等值参数可减少电压稳定问题突出的电网所需要的稳定措施量。
3.
In off-line power flow studies, as the equivalent impedance of a transformer is directly given, it is not necessary to consider the effect of tap changer regulation on the impedance of a transformer when a transformer model is selected.
离线潮流计算中,变压器等值阻抗是直接给定的,因而使用变压器模型通常无需考虑变压器分接头对等值阻抗的影响。
补充资料:星接阻抗和三角接阻抗的变换
星接阻抗和三角接阻抗的变换
transformation between starc-onnected and delta-connected impedances
x ing]一e乙日kongl介e sonJ一00}Iez日伙ongde匕一。一〕huon星接阻抗和三角接阻抗的变换(t ransfor-mation betweenstar一eonneeted and delta-eonneeted imPedanees)接成星形的三个阻抗和接成三角形的三个阻抗互相替代的等效变换。它们之间的关系可用一组变换公式表示。按这组公式,用星接阻抗替换三角接阻抗或者反过来,不会影响稳态下电路其他部分的正弦电压和电流,常用于对称三相电路的分析和计算。 图1为三个阻抗21、Z:、23接成星形(又称丫形)。图2为三个阻抗Z小22。、Zal接成三角形(又称△形)。它们之间的变换公式如下:人23土图1星接阻抗图2三角接阻抗(1)将星形连接变换成三角形连接212一Z:+22+2 122及3一22+za十警(1)、|冬|矛231一23+21+2321(2)将三角形连接变换成星形连接z、-二一典乒兴-) 艺‘2士乙“3十乙31…_2 oqZI,}Z。一下万~一二-二二-汁 乙‘2士乙23十乙3‘1_Z。IZoq}艺q一二二一~二,二二--,-二二-~J 乙12十乙23十艺32夕(2) 当三个星接阻抗相等,即21一Z:一23一z丫、三个三角接阻抗相等即212一223一231一Z△时,变换公式是 Z二一32丫,Z丫一Z△/3
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条