说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 重合闸拒动
1)  reclosure failure
重合闸拒动
1.
The cause of the reclosure failure of WXB?11 line protection is analyzed when it is applied with local power source.
分析了当WXB 11型微机线路保护应用在带小电源的线路时 ,重合闸拒动的原因。
2)  auto-reclosing
自动重合闸
1.
Implementation of intelligent auto-reclosing with DSP;
用DSP实现智能化自动重合闸
2.
Case study of power system auto-reclosing logic;
电力系统自动重合闸的案例逻辑分析
3.
A new technique of employing auto-reclosing technology for single-phase-to-ground fault clearing in non-valid grounded power systems is also presented.
通过小电流接地电网单相接地选线装置得到的现场数据的分析,提出了除瞬间接地故障和永久性接地故障之外的第3种接地故障——短时接地故障的概念,提出了在小电流接地系统中引入面向单相接地故障的自动重合闸技术(简称接地重合闸)的新技术,它同样适用于谐振接地系统中,有利于故障的快速消除,提高了系统的供电可靠性。
3)  autoreclosure
自动重合闸
4)  auto-reclosure
自动重合闸
1.
Study of auto-reclosure strategy for high temperature superconducting cable;
高温超导电缆自动重合闸方案研究
2.
Aiming at the unreliable factors that the traditional electromagnetic ARD device has more action grades and adhering of contact, using PLC to realize the auto-reclosure and making the design for hardware and software, the used components is fewer, accident chance is much lower.
针对传统的电磁式重合闸装置存在动作级数多、触点粘连等不可靠因素,采用PLC实现自动重合闸,对其进行硬件设计和软件编程,所用元件极少,故障率大大降低,克服了电磁式重合闸控制方式的不足。
3.
On the basis of analyzing the factors influencing the measurement accuracy of traveling wave velocity,the influence of traveling wave velocity on fault location accuracy and existing measuring methods of traveling wave velocity, using the wave of single-phase auto-reclosure to measure the traveling wave velocity is proposed for single-phase gr.
行波故障测距系统中的行波波速测量的准确性在一定程度上影响了行波测距的精度,文章在对影响行波波速测量准确性的因素、行波波速对测距精度的影响及现有行波波速测量方法进行分析的基础上,提出一种输电线路发生单相接地故障时利用单相自动重合闸产生的行波在线测量线路行波波速的方案,实现了行波波速的在线测量和调整。
5)  autoreclose maloperation
重合闸误动
6)  automatic reclosing
自动重合闸
1.
Based on the author s experience in adjustment test and the study on the diagram of diagnosis and detection of shortcircuit,the principles of coordination between diagnosing and detecting shortcircuit and automatic reclosing in D.
根据调试经验和对线路短路判別测试电路图的研究,阐述了直流牵引网线路短路判別测试与自动重合闸的配合原理。
2.
The system can inspect the change of current in real time and perform such functions as alarming, opening, automatic reclosing, recording and faults displaying.
设计了一种以AVR单片机为控制器的配电变压器反时限过流保护系统,该系统能实时监测变压器负载大小,根据负载情况进行报警、切闸,能实现自动重合闸功能,能进行故障记录及查询。
3.
This paper introduces the coordination of automatic reclosing of circuit breaker in line-transformer strings with 3/2 connection and the relay protection.
介绍了3/2接线特殊运行方式下线变串开关自动重合闸与保护配合的情况。
补充资料:非同步重合闸


非同步重合闸
auto-reclosing without synchronism check-ing between line and bus voltages

feltongbu ehonghezho非同步t合闸(auto一reelosing without Syn-ehronism eheeking between line and bus volt-ages)见三相重合一词。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条