1)  residual current operated protective device
漏电电流动作保护器(RCD)
2)  electricity leakage
漏电
1.
The paper demonstrates the authors' understanding of the regulations about electricity leakage fire alarm system in the national standards,and describes the application of system design and main technical parameters of this system.
给出了对国家标准中关于漏电火灾报警系统设计规定的理解与认识,论述了漏电火灾报警系统的设计应用与主要技术参数。
2.
This paper analyzed the protection principle of all kinds of electricity leakage relays used in coal mine and their merits and shortcomings,then put forward a comprehensive scheme of electricity lea-(kage) protection used in underground.
阐述了适合于煤矿井下应用的全面漏电保护方案。
3.
The paper introduces fire danger by electricity leakage of low-voltage distribution system, analyzes the causes of the fire disaster due to the leakage and gives out the protective measures.
介绍了低压配电系统漏电产生的电流和电压引起的火灾的危害性,分析了低压配电系统漏电导致电气火灾的原因,给出了防范漏电的技术措施。
3)  leakage
漏电
1.
Talking about underground leakage causes and preventive measures;
浅谈井下漏电原因及预防措施
2.
on the basis of analyzing and researching the reason of the current leakage with the underground D.
本文分析研究了煤矿井下直流架空线电网产生漏电的原因,总结了漏电保护研究的现状,并在此基础上阐述了基于附加直流电源的煤矿井下直流架空线电网漏电保护的原理。
3.
And analysis is made on the leakage of the DC 600 V power supply system.
介绍了发电车交流供电系统的接地保护方式,以及交流供电系统、DC 600 V供电系统接地方式的改进,并对DC 600 V供电系统的漏电问题进行了分析。
4)  electric leakage
漏电
1.
Cascading electric leakage fire warning system based on CAN bus;
基于CAN总线的级联漏电火灾报警系统
2.
Study on Electric Leakage and Electric Leakage Protective Instrument;
漏电检测与智能鉴相漏电保护器的研究
3.
The viewpoint of the electric leakage protect in low-pressure electric wire;
井下低压电网漏电保护分析
5)  leakage of electricity
漏电
1.
In the light of the cause of electrical fire, the paper emphasizes the necessity of installing protective unit to prevent the leakage of electricity.
本文通过电气火灾的起因 ,提出安装漏电保护器的必要性 ,并对如何正确选择、安装、使用漏电保护器进行了论
2.
In accordance with the role of leakage of electricity protective device in capital construction, the classes, development procedure, and working principle of leakage of electricity protective device set forth.
针对漏电保护装置在基建建设中所起的作用,阐述了漏电保护装置的分类、发展过程及工作原理。
6)  creepage
漏电
1.
Fire danger and technical preventive measures of creepage in low-voltage distribution system;
低压配电系统中漏电的火灾危险性及其技术防范措施
2.
It tells about the tingling and creepage in one - way circuit equipment and analyses the cause of electrified outer covering (faradism、creepage) ,the difference of their normal and abnormal electrification,and ways to remove electrification in outer covering (meet cipher protect、earth protect).
介绍了单相用电设备的麻电和漏电现象,分析设备外壳带电的原因(两种情况:感应电,漏电),外壳正常带电和非正常带电的区别,以及消除外壳带电的措施和方法(接零保护,接地保护)。
3.
It can improve the breakdown field and reliable performances, reduce and even remove the defections such as creepage, sparking,breakown and so on in working.
主要介绍了一种将有机材料[1]和无机介质层进行复合,以提高电致发光显示器中介质层绝缘性能的方法,通过这种复合方法提高了器件中介质层的耐压可靠性,减少甚至消除了器件在工作时出现的漏电、打火、击穿等现象。
参考词条
补充资料:漏电电流动作保护器


漏电电流动作保护器
residual current operated protective devices

  标志之一.一些技术先进的国家对安全用电的基本理论和触电保护装t的生产和应用十分重视,从20世纪初开始研制,到20世纪末已经建立了一套完整的体系,制定了一系列技术标准和有关规程,触电保护装置得到普追应用. 日本于1965年研制漏电保护器,并使电压型漏电保护器规格化。1967年电设工业协会发表汤电保护器纲要。1969年产业安全研究所制定了《防止触电用的翻电保护器构造标准》,并于1972年进行修改和增补.1971年电机工业会制定TJEM1244一1971《漏电保护器技术标准》。1974年颁布T JISC8371一2974《汤电保护器规程》。1977年修订了《电气用品取缔法》、《电线规程》,扩大了必须装设触电保护器的场所和范围。 德国于1912年研制电压型保护器,1930年制定VDE标准,电压型保护器规格化,1950年开始生产电流型保护器,并于1963年制定VDE标准,电流型保护器规格化,1965年试制动作值为30 mA的电流型保护器。 英国1939年制定以二一842标准,电压型保护器规格化,1968年制定BS一4293标准,电流型保护器规格化。 法国1957年开始使用电流型保护器,1965年试制动作值为30 mA的电流型保护器。 美国1972年11月制定了UL943.1053标准,电流型保护器规格化.1971年版的国家电气规范(NEC)对汤电保护器的安装使用做了明确规定。 1969年11月国际电工技术委员会德黑兰大会上由TC64、汉二12B(对于收音机的安全问题)、TC61(对家庭用电设备的安全间题)等专门委员会提出了讨论扮电保护器的倡议,并举行了非正式座谈会.197。年6月在布鲁塞尔召开的TC23(电气附件、配电工具等)专门委员会和SC17B(低压开关装置和控制装t)专门委员会的会议上讨论了扮电保护器,决定接受SC23E(家雇用开关和同类装t)专门委员会委托并拟定了IEC标准草案。第一次草案于1 972年5月由SC23E专门委员会提交给TC23的各国委员会,定名为“低压设备防止触电事故的装里”。1974年2月向各国委员会提出了第二次草案的第一部分一剩余电流保护装里的要求。TC64专门委员会对电流动作型定名为“剩余电流动作保护装里”,IEC标准中采用了这个名称。