1) high impedance differential protection
高阻抗差动保护
1.
Principle, setting and application of high impedance differential protection in large motor;
大型电动机高阻抗差动保护原理、整定及应用
2) mid-impedance bus differential protection
中阻抗母线差动保护
1.
Simply analyzing the countermeasure of mid-impedance bus differential protection′s rectifying circuit;
浅析中阻抗母线差动保护整流回路反措
3) medium impedance busbar differential protection
中阻抗母差保护
1.
Analysis and countermeausres of one mal-operation of medium impedance busbar differential protection occurred in 110kV system;
一起110kV中阻抗母差保护误动的原因分析与措施
4) high impedance differential protection
高阻抗差动
1.
Misoperation of high impedance differential protection for main transformer;
一起主变高阻抗差动保护误动分析
5) impedance protection
阻抗保护
1.
Analysis on defects of impedance protection for transformer;
变压器阻抗保护缺陷的分析
2.
On basis of actual condition at site and with reference of theoretical analysis and calculation, analyzes the parameter setting for impedance at load side in quadrangular impedance protection at present time, points out its imperfection, brings up the setting method for impedance at the load side and therefore improves the accuracy for quadrangular impedance protection setting.
本文根据现场实际情况,结合理论分析计算,对目前四边形阻抗保护中负荷边阻抗值的参数取值进行了分析,指出了不足之处,提出了负荷边阻抗值新的整定方法,由此提高了四边形阻抗保护整定值的准确性。
3.
This article quantitatively analyzes the formation of remote impedance protection dead zone of WXB-63 computer feeder protection device, proposes the counter measures for elimination of remote protection dead zone by means of adjusting the offset resistance which may protect the whole length of line without modifying the soft and hard ware of device.
本文用短路试验数据定量地分析了WXB-63型微机馈线保护装置阻抗保护远端死区的形成,并提出了通过调整偏移电阻的方法来消除远端保护死区的解决方案,可以在不改变装置原有软、硬件的情况下保护线路全长。
6) high auxiliary differencial protection
高备变差动保护
1.
Through wrong acting cause analyse of high auxiliary differencial protection,it pay more attation to current sample collecting prevent similar situation occur.
通过高备变差动保护一次误动原因的分析,指出对电流采样环节应特别引起重视,防止类似情况的发生。
补充资料:变压器差动保护系统调试
变压器差动保护系统调试
commissioning of the differ- ential protection system for transformer
b ianyaqi chadong baohu xitong tiaoshi变压器睡动保护系统调试(eommissioningof the differential Proteetion system for trans-former)对流入变压器和自变压器流出的两侧电流,经电流互感器检测变换之后进行比较,其电流差值反映出变压器的内部故障情况.根据这一原理,由电流互感器、差动继电器、断路器跳闸机构组成的保护系统称为变压器差动保护系统.当电流互感器的变比和结线方式与被保护的变压器相适应时,变压器正常运行电流及变压器以外的穿越性故障电流不会使差动保护动作.空载变压器接入电源时,电源侧向变压器流入较大的励磁涌流,为减少它对保护系统的影响,消除误动作,变压器差动保护系统中设有速饱和变流器或谐波制动电路。变压器差动保护系统的调试分差动保护继电器的单体调试和差动保护系统模拟试验两个步骤. 差动保护继电器的单体调试变压器差动保护继电器依其结构特点可分为机电型、整流型、静态型等。机电型差动保护继电器由速饱和变流器、电磁动作的执行继电器、换档擂接板等组成,其调试项目主要有:(1)外观检查,插接与机械动作部分的检查和调整。(2)电磁式执行继电器的常规调试。(3)速饱和变流器的特性试验:检查各绕组极性与结线的正确性;测定变流器伏安特性曲线;通入试验电流,测定执行继电器动作时各绕组分档的动作电流安匝数,并将其整定到设计规定的范围内;测定直流助磁特性,即测定相对动作电流。=(‘/i。)和偏移系数K(1/1)间的函数关系。式中,I为速饱和变流器一次侧通入的直流试验电流(A)八为通入直流分量I时速饱和变流器一次侧的交流动作电流(A);i。为未通直流分量时的交流动作电流(A)。(4)在整定位置下测定保护继电器的整组伏安特性,即差动继电器输入差动电流信号安匝数与执行继电器线圈端电压之间的关系,以判别差动继电器工作磁通密度选取是否合适。 整流型差动保护继电器由差动元件和瞬动元件两部分组成。差动元件包括工作回路、比率制动回路、谐波制动回路及直流比较回路。调试项目主要有:(l)工作回路最小动作电流与返回电流的测定,动作电流整定。(2)比率制动回路动作特性试验。给工作回路和制动回路同时通入试验电流,测定继电器产生输出动作时两试验电流数,绘制出它们的函数关系曲线(即比率动作特性曲线),按照保护设计要求对比率动作特性进行整定。在无特殊要求时,两试验电流取同相位电流。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条