1) generator impedance protection
发电机阻抗保护
2) impedance protection
阻抗保护
1.
Analysis on defects of impedance protection for transformer;
变压器阻抗保护缺陷的分析
2.
On basis of actual condition at site and with reference of theoretical analysis and calculation, analyzes the parameter setting for impedance at load side in quadrangular impedance protection at present time, points out its imperfection, brings up the setting method for impedance at the load side and therefore improves the accuracy for quadrangular impedance protection setting.
本文根据现场实际情况,结合理论分析计算,对目前四边形阻抗保护中负荷边阻抗值的参数取值进行了分析,指出了不足之处,提出了负荷边阻抗值新的整定方法,由此提高了四边形阻抗保护整定值的准确性。
3.
This article quantitatively analyzes the formation of remote impedance protection dead zone of WXB-63 computer feeder protection device, proposes the counter measures for elimination of remote protection dead zone by means of adjusting the offset resistance which may protect the whole length of line without modifying the soft and hard ware of device.
本文用短路试验数据定量地分析了WXB-63型微机馈线保护装置阻抗保护远端死区的形成,并提出了通过调整偏移电阻的方法来消除远端保护死区的解决方案,可以在不改变装置原有软、硬件的情况下保护线路全长。
3) generator protection
发电机保护
1.
100 MW and above generator protection operational analysis from 1998 to 2002;
1998~2002年100MW及以上发电机保护运行情况与分析
2.
In this paper, the current situation and problems of the microprocessor based generator protection is presented based on the dynamic simulation test results of many kinds of protections manufactured at home and abroad.
近年来 ,微机型元件保护装置的研制和开发逐渐成熟 ,其应用也日趋广泛 ,通过对国内外厂家生产的多种保护进行动态模拟试验 ,在对动模试验结果进行全面深入分析研究的基础上 ,阐述了微机型变压器保护、微机型发电机保护装置的现状和存在的问题。
3.
The statistics and analysis of operation situation of primary equipments in 220 kV and above power systems, including main protections of transmission lines, transformer protections, busbar protections, fault recorder and generator protections for 100MW and above generation units as well as the statistics of faults occurred in these equipments are given.
介绍了2007年国家电网公司继电保护装置的运行情况,包括220kV及以上系统一次设备的运行及故障情况,220kV及以上线路保护、变压器保护、母线保护和故障录波器、100MW及以上发电机保护等的运行情况。
4) generator protection computation by microcomputer
微机发电机保护
5) safeguard-resistor
保护电阻
1.
In this paper,current-resistance curves respects to different connection of safeguard-resistor are drawn by means of Software Microcal Origin.
本文根据戴维宁定理 ,将待测电路等效为一个有源二端线性网络 ,用MicrocalOrigin软件模拟绘制了保护电阻在不同接法下 ,分别流过检流计、保护电阻、待测电路中的电流随保护电阻的变化曲线 ,通过对曲线的分析 ,对保护电阻的作用及使用提出了自己的观
6) generator interturn protection
发电机匝间保护
补充资料:抽水蓄能发电电动机继电保护
抽水蓄能发电电动机继电保护
generator/motor
ehoushu一xu’neng fod一on一d一ondongJ一J一d一on boohu抽水,能发电电动机继电保护(r elay protec-tion of pumped storage generator/motor)检侧发电电动机电气故障或异常运行工况,并发出保安操作指令或报警信号,以终止故障发展的自动化技术及装t。可逆式机组是当前抽水蓄能电站采用的主要机型,这种机组作发电工况运行时,其继电保护的要求与水轮发电机继电保护一样,而作抽水工况运行时,除了为发电工况所配的继电保护装置需投入外,还要针对机组抽水工况的起动过程、电动机运行工况和电气主回路的相序变换等3种情况作特殊考虑。 抽水工况起动过程的继电保护需考虑的保护:①要设里起动失败保护。根据不同的起动方式(见抽水蓄能机组起动方式)采取不同措施。对于异步起动方式或同轴小电机起动方式,起动时若机组在预定的时间未被拖动到规定的转速,这将出现发电电动机或同轴小电机长时间过电流,可利用这种现象来判明起动失败;对于同步起动则可设失步保护。②当采用同步起动时,在机组转速从零逐渐上升到额定值的过程中,机组始终处于励磁和带电状态,故继电保护应起作用。有些保护装置的动作值受频率影响很大,对在低颇区内灵敏性很低的保护装置,要增设低频时能正确反应机组事故的附加保护;在低频区会误动的,应将其闭锁。当机组采用发电电动机一变压器组接线时,由于在起动过程的低频区内机端电压如果过高,变压器会产生很大的励磁电流,故需装设变压器过励磁保护。③当采用主变压器低压侧三角连接绕组的对称中心抽头作电动机半电压起动时,半电压和全电压间相位差600,故半电压起动时要对变压器差动保护的电流相位作相应的处理,以保持电流相位一致。 电动机运行工况的继电保护需要装设的保护:①需设电动机断电保护.当电动机电源消失时,机组在上库水头压力作用下,转速会迅速下降,经零点后往反方向旋转,甚至会达到飞逸转速,同时机组会发生较剧烈的水力振动,危及机组的安全。为此,一般装设低功率保护和低频率保护。②装设防御电动机异步运行的失步保护。③当需要时,装设防御电力系统电压过低而不能维持电动机正常运行的低电压保护。 主回路相序变换的继电保护需要考虑的保护:①换相开关的保护是最主要的问题。当换相开关在变压器或电机的差动保护范围内时,则在发电和抽水两种不同工况下,要保证差动继电器两侧的电流互感器二次侧电流相位相对应。