This paper introduces two operational models in the ice storage air conditioning system, whichs are the water cooled chillers priority and the ice storage priority, the choice method of refrigeration unit, the computing method of the amount of water stored and the disposition of the ice storage system.
介绍了冰蓄冷空调系统中冷水机组优先和冰优先的两种运行模式及其两种运行模式制冷机组的选择方法和储水量的计算方法,以及冰蓄冷系统的配置。
2)  chiller priority mode
冷机优先
3)  water chiller
冷水机组
1.
Design and development of an indirect evaporative water chiller;
间接蒸发冷水机组设计开发及性能分析
2.
Technical ways to Improve the energy efficiency of water chillers;
提高冷水机组能效的技术措施
3.
Optimization control strategy in air conditioning system with multi water chillers;
多台冷水机组空调系统的优化控制
4)  water chiller unit
冷水机组
1.
To solve the unstable operation of the water chiller unit, probes into the feasibility of fresh air cooling for a clean room and provides a design procedure verified with an example in Beijing.
针对北方地区洁净室冬季供冷时冷水机组运行不稳定的问题 ,研究了采用新风作为冬季冷源的可行性 ,给出了具体设计方法 ,并利用北京地区的设计实例作了验证。
2.
In this paper,the influences of variable chilled water flowrate on the performance of water chiller unit were studied.
本文对变冷冻水流量对冷水机组性能的影响规律进行了深入研究,首先建立了冷水机组数学模型,并进行变冷冻水流量对机组性能影响仿真,而后得出了其对机组性能影响的变化规律,同时研制出试验样机并进行试验验证。
3.
This paper analyses the energy consumption and running costs of two design options for sizing water chiller units, that is the asymmetric design option and the blended design option, and points out that the two options should be considered to optimize the design of airconditioning system while sizing water chiller units.
分析了冷水机组设计选型中所采用的不对称设计和混合设计两种方案的能耗和运行费用,指出在冷水机组设计选型中应考虑这两种方案,以优化系统设计。
5)  Chiller [英]['tʃilə]  [美]['tʃɪlɚ]
冷水机组
1.
The World Chiller and Large AC Market in 2006(Part one);
2006年全世界冷水机组和大型空调市场(一)
2.
Output distribution of a multiple chiller system under part load conditions;
部分负荷工况下多台冷水机组的冷量分配
3.
Discussion and review on the models of vapour-compression heat pumps and chillers;
蒸气压缩式热泵与冷水机组模型回顾及探讨
6)  water chilling unit
冷水机组
1.
Choice of centrifugal water chilling unit in engineering design;
工程设计中离心式冷水机组的选择
2.
Combined with the practical program,it analyses the characters of different types of water chilling unit,in condition of partial load,the change of energy consumption of water chilling unit and pump,the optimum of the match of the large and small equipment,and mainly compares the merits and defaults of separate refrigerating station,first pump system and second pump system.
结合实际项目,分析了不同类型冷水机组的特点,在部分负荷条件下,制冷机组和水泵的能耗变化,大小机搭配的优势,重点比较了分设制冷站、一次泵系统和二次泵系统的优缺点。
3.
A software for fault diagnosis of water chilling unit is developed by applying fuzzy theory and artificial neural network in expert system.
将模糊理论和人工神经网络运用于专家系统,开发出冷水机组故障诊断软件,以活塞式冷水机组作为实验平台验证了软件的运行效果良好。