说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 场畸变开关
1)  field distortion switch
场畸变开关
1.
In this paper,a novel field distortion switch with carbon fiber/metal matrix composites electrodes is designed to replace the surface flashover discharging switch in TomaChan.
介绍了电极用碳纤维—金属基复合材料制成的新型场畸变开关
2.
The results show that the system can produce the pulse with fast rising edge,high slope and high amplitude,which is significant for the further development of field distortion switch with the high performance of low-jitter and rapid discharging.
仿真结果表明,该系统能产生快上升沿、高陡度、大幅值的脉冲,这对进一步研制放电抖动低、放电迅速等高性能的场畸变开关具有一定实际意义。
2)  field distortion spark gap
场畸变火花开关
1.
5 kJ Mather-type DPF energy supply device composed of a pulse capacitor,field distortion spark gap,contact socket and transmission line is developed and debugged,in which the circuit inductance about 57 nH,peak current over 400 kA,and a delay in 80 ns range with jetty less than 15 ns can be achieved when operation voltage is 25 kV.
介绍了由脉冲电容器、开关组成的DPF能源装置及其调试,详述了场畸变火花开关、接插口及传输线的设计要点。
3)  spark global gap with triple electrodes
三电极场畸变点火球隙开关
1.
Surge generator was developed by using spark global gap with triple electrodes as switch.
为了使瞬态电磁干扰信号发生器在微机保护装置电磁兼容设计过程中普及应用,分别以高压直流开关电源、氢闸流管研制了电快速瞬变脉冲群(electrical fast transient/burst,EFT)发生器和以三电极场畸变点火球隙开关研制了浪涌发生器。
4)  electrical field distortion
场强畸变
5)  magnetic field distortion
磁场畸变
1.
In order to establish a precise nonlinear model for turbo-generators,FEM was employed to study three nonlinear factors(including the main flux saturation,the rotor yoke saturation caused by excitation flux leakage and the magnetic field distortion).
为了建立汽轮发电机的精确的非线性模型,以有限元方法为工具,系统研究了汽轮发电机的3种非线性因素,即主磁通饱和效应、励磁电流漏磁通导致的转子轭部附加饱和效应及磁场畸变非线性。
2.
Two factors of iron saturation and magnetic field distortion affecting such nonlinear characteristics are presented in this paper.
通过理论分析和有限元计算相结合的方法,以一台300MW汽轮发电机为例,对其在正常和非正常运行状态下的非线性特性曲线族和磁场分布进行了系统研究和分析,提出主要是由于铁心饱和与磁场畸变两个因素的影响,导致了汽轮发电机复杂的非线性特性。
3.
The distinction is due to the nonlinear characteristics of iron saturation and magnetic field distortion widely existed in large turbine generators under load conditions.
揭示了不同运行条件下4种汽轮发电机的负载非线性特性均与各自空载特性存在显著差别,而出现这种差别的原因在于大型汽轮发电机在负载运行时普遍存在铁磁饱和与磁场畸变非线性。
6)  electric field distortion
电场畸变
1.
Based on the MLCC internal structure,the structure of the reasons caused MLCC inside electric field distortion and the uneven distribution of current were analyszed.
从MLCC内部结构入手,分析了造成其电场畸变和电流分布不均匀的原因。
2.
Meanwhile the corona discharge of different type transmission lines caused by electric field distortion of iced-line are compared.
对于不同输电形式架空线由于覆冰等情况下电场畸变所引起的电晕现象进行了对比分析,并依据模拟电荷法定性的模拟了空间电荷对双极±500KV导线之间的电位及电场的影响。
3.
It is concluded that the main reason is the damage of the insulation shielding layer of cable caused by improper construction and the ensuing serious electric field distortion;the damp of joint and the poor contact caused by improper installation of joint accelerate the main insulation breakdown.
分析结果认为:施工不当造成电缆绝缘屏蔽层受损,引发电场畸变严重,是引起事故的主要原因;接头的安装工艺不当引起接头受潮和接触不良,加速了主绝缘击穿的进程。
补充资料:换流站交流开关场故障


换流站交流开关场故障
faults in the AC switch yard of converter station

  huonl一uzhonJ一001}u ko一guonehong guZhong换流站交流开关场故障(faults in the ACswiteh yard of eonverter station)主要指发生在换流站交流开关场范围内的故障,即发生于换流母线、换流变压器、交流滤波器、并联电杭器或其它无功补偿设备、交流断路器及隔离开关、连接导线等主回路或交流主设备的故障。按照故障对直流系统的影响可分为与换流器并联设备故障和主回路设备故障两类。 与换流器并联的设备故障,如交流滤波器、无功补偿装里及其连线部分的故障。这部分故障将由交流系统提供故障电流,故障电流的大小取决于交流系统的强弱。如果故障设备退出运行将引起交直流系统交换无功的不平衡,或在交流系统中产生的谐波分量增大,进而引起直流系统的停运。交流滤波器和并联电容器组发生的故障通常为内部短路故障。滤波器中的电容器结构安排为“H”的对称桥形,当一个或数个电容元件短路损坏并达到一定数量时,将在健全的电容器元件上形成不可接受的过电压应力。此外,由于设计不当或非正常的运行可能引起交流滤波器内部的电阻器或电抗器元件的谐波过负荷,以造成元部件的过热。在交流滤波器的并联电路中元部件发生短路时,同时还会引起其单相阻抗的改变,在滤波器中出现零序电流及引起交流滤波器的失谐。与常规交流系统中同等电压等级的交流断路器相比、交流滤波器断路器投切频繁,且投切时的电容电流和涌流很大,因此设计时应考虑足够的裕度,以确保直流系统的安全运行。 主回路交流设备故障,主要指换流母线、换流变压器及其网侧断路器,以及换流变压器至换流器之间的连线等处的故障。对于整流侧,发生换流母线单相短路时,直流电压将降低,直流输送功率将减少,同时直流电压中含有IOOH:的谐波。整流侧换流母线发生三相短路时,将失去换相电压,直流输送功率将为零。对于逆变侧,当交流系统发生故障时,由于换流器交流侧电压降低,引起直流反电动势降低、直流电流瞬时增大,如果电压下降严重,会继而引起换相角的明显增大,这些都将可能最终导致逆变器的换相失败。 特别要指出的是,如果在运行中逆变侧的换流变压器网侧断路器发生无故障跳闸,则视断开点和交流滤波器投人的组数不同,而产生数倍的过电压,相关的设备将承受很大的应力。 换流变压器故障除本体故障与常规变压器相同外,还应特别注意其阀侧绕组对地短路故障,其故障点与站内接地网形成回路,相当于换流桥的桥行短路(见换流器故阵)。此外,换流变压器的冷却系统故障、分接头控制和执行机构的故障,都将可能导致设备的损坏和直流系统的停运。当换流变压器投切时,往往会产生较大的激磁涌流,必须避免在某些情况下可能导致交流系统继电保护的误动.直流输电系统在正常或暂态工况下,会产生各种特征或非特征谐波,应该注意这些谐波对交流系统中继电保护的影响。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条