说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 冷贮备系统
1)  Cold standby system
冷贮备系统
1.
Bayes estimation for reliability indexes of cold standby system;
冷贮备系统可靠性指标的Bayes估计
2.
Multiple Bayes estimates of the reliability performance for cold standby system;
冷贮备系统可靠性指标的多层 Bayes 估计
3.
Reliability analysis of the two dissimilar units cold standby system with preventive repair policy;
具有预防维修策略的两个不同型部件组成的冷贮备系统的可靠性分析
2)  cold-standby system
冷贮备系统
1.
And the point estimation of the reliability for the cold-standby system is obtained.
由伽玛型元件和指数型开关的定数截尾观察数据给出未知参数的极大似然估计,进而得出冷贮备系统的可靠性的点估计,并给出了系统可靠性的Bootstrap置信限,经过数值模拟验证了该方法求系统可靠性置信限的可行性。
3)  cold standby series system
冷贮备串联系统
1.
Approximate confidence limits of the reliability performances for cold standby series system based on progressively type-Ⅱcensored tests;
逐步增加的Ⅱ型截尾下冷贮备串联系统可靠性指标的Bayes估计
2.
Empirical Bayes Approximate Confidence Limits of the Reliability Performances for Cold Standby Series System;
冷贮备串联系统可靠性指标的经验Bayes近似置信限
3.
We firstly give Bayes estimators of the parameter and reliability performances;secondly, two-sample prediction intervals for future observation are obtained using Bayesian method;in the end, we research on the cold standby series system and derive the approximate confidence limits of the reliability performances.
在逐次截尾样本和随机截尾样本下,以Burr Ⅻ分布为基本模型,首先对Burr Ⅻ分布的参数及其可靠性指标进行了Bayes估计;其次运用Bayes方法讨论了Burr Ⅻ分布的双样预测问题;最后对冷贮备串联系统的可靠性进行研究,给出了可靠性指标的经验Bayes近似置信限。
4)  cold standby repairable system
冷贮备可修系统
1.
This paper considers a n-unit cold standby repairable system with two repair facility.
n个同型部件和两个修理设备组成的冷贮备可修系统中,假设部件的寿命和部件故障后的修理时间都服从指数分布。
5)  standby system
贮备系统
1.
The bootstrap confidence limit of reliability for standby system;
贮备系统可靠性的 bootstrap 置信限
2.
In this paper, we discuss the lower confidence limits of reliability for single standby system and for the series system which consists of two standby systems based on fixed number testing data of components.
基于元件的定数截尾寿命试验数据 ,在元件的失效率间满足某种关系时 ,给出了单个贮备系统、两贮备系统组成的串联系统的可靠性的置信下限 ,给出了数字
3.
In the paper, the approximate confidence limits of the reliability for the system consisting of two standby systems are discussed.
讨论了由两贮备系统组成的串联系统可靠性的近似置信限。
6)  stand-by system
贮备系统
1.
The reliability model of hot stand-by system by consisted of n equipments possessing constant failure rate and a imperfect transform switch possessing constant reliability or constant failure rate is established.
针对n台可靠度负指数分布的设备组成的热贮备系统,其中转换开关的可靠度或者是常数或者是负指数分布的情况,建立了转换开关不完全可靠的热贮备系统可靠性模型。
补充资料:空冷发电机空气系统


空冷发电机空气系统
air system for air cooled generator

  kong]eng fod一anjl kongq一xltong空冷发电机空气系统(air system fo:eooled generator)利用空气作为冷却介质平发电机定子和转子绕组以及定子铁芯进行冷却统。该系统通常有开式通风和闭式循环两种冷却丈 开式通风开式通风直接利用发电机周围的作为冷却介质,一般由空气吸人口、过滤器、人口器、出口消声器及出口风道等组成。空气由装在发alr随陈丸气庐肌转子上的风扇吸人并送到发电机各发热部位进行冷却,然后经出口消音器及出口风道排出,示意图见图1。这种冷却方式费用低,但仅适用于周围空气比较清洁且不含有盐雾大气消声器过雄签周围空气图1开式通风冷却和空气温度比较低的场合,否则将引起发电机内道堵塞或发电机金属部件(如护环)腐蚀而影响发的安全运行。 闭式循环发电机的冷却空气在冷却系统内闭路循环。因此需要设置水一空气冷却器以带走空的热盘,其示意图见图2,当发电机落地安装时(风机 空气冷却器可多图2闭式循环冷却用于嫌气轮机机:其空气冷却器可-在发电机机壳内.电机安装在框架础上时(一般用于机机组).其空气,器可布t在发电二础下的风道内.空气冷却器的冷却水一般采用闭却水。当开式冷却水的水质较好,且机组容量较刁也可采用开式冷却水。采用闭式冷却水冷却时,必证冷却空气的温度满足发电机技术规范的要求,要设里冷却水进水温度和冷却后空气温度的监:里。戚冲搬L),1泼邀滋却基冷东降附嚷
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条