1) power frequency voltage
工频电压
1.
When lightning hits the transmission lines,the power frequency voltage always exists on the lines and the value of the voltage is random.
为研究工频电压对输电线路反击跳闸率和绕击跳闸率产生的影响,验证目前的试验结果,从工频叠加影响机理、蒙特卡罗法实例计算两个方面进行了计算和分析。
2) power frequency overvoltage
工频过电压
1.
During the restoration of black-out in the power system,the power frequency overvoltage caused by the capacitive effect of a non-loaded long overhead lines and the switching overvoltage by closing non-loaded long overhead lines are important factors to establish the restoration scheme.
在电力系统发生大停电事故后的恢复过程中,控制启动方案中的重要因素即充电空载长线路时的工频过电压与合闸空载长线路时的操作过电压,分析了电压源换流器直流输电(VSC-HVDC)技术用于联网的优势,及由空载长线路电容效应引起的工频过电压与合闸空载线路引起的操作过电压的形成机理;提出利用联网的VSC-HVDC抑制空载长线路工频过电压与操作过电压的概念以及相应的过电压控制策略与系统并建立了联网的VSC-HVDC启动空载线路的数学模型。
2.
The power frequency overvoltage of unloaded line because of the capacity effect is studied,and the effect of eliminating power frequency overvoltage using shunt reactors is analyzed.
讨论了空载线路在电容效应下产生的工频过电压,并对并联电抗器抑制工频过电压的作用进行了理论分析。
3.
The results show tha t the power frequency overvoltage and switching overvoltage are all within the limita-tion of design criteria if the line is around200km,so it needs no speci al means to limit these overvoltages except some shunt reactors added on the lin e.
建立了一个110kV长线供电系统模型,用软件EMTP对该系统进行了工频过电压和操作过电压的计算。
3) power frequency over-voltage
工频过电压
1.
Analysis of power frequency over-voltage for unloaded lines by using PSCAD/EMTDC
基于PSCAD/EMTDC软件的空载线路工频过电压分析
2.
The power frequency over-voltage,the secondary arc current,and the recovery voltage of the lines with different tower types and various phase order arrangement are studied under different system operational modes.
介绍了几种塔型结构、相序布置在不同系统运行方式下的线路工频过电压、潜供电流和恢复电压的研究情况,分析了塔型和相序变化对工频过电压和潜供电流的影响,并提出了结论和建议。
3.
The ZnO varistor is tested for the performance of the clamping voltage and power frequency over-voltage withstanding time.
对氧化锌压敏电阻器的限制电压和工频过电压耐受时间的试验测试,结果表明,相同型号的氧化锌压敏电阻器,其限制电压越高,则耐受工频过电压的时间越长。
5) High voltage power frequence electric field
高压工频电场
6) rated frequency resume voltage
工频恢复电压
1.
The rated frequency resume voltage switching is related to neutral grounding operation modes,short-circuit fault modes and the order of three-phase circuit when the circuit-breaker switches off three-phase circuit.
断路器在开断三相电路时工频恢复电压大小与系统的中性点接地方式及短路故障方式有关,且因断路器开断三相电路的顺序而异。
补充资料:电力系统工频过电压
电力系统工频过电压
power frequency over-voltage in eletric power system
器的惰性,E值暂时保持不变,加上长线路的电容效应,母线电压有所升高、线路工颇电压则上升得较高,称为暂时工频过电压。在经数百毫秒之后,发电机自动电压调整器发生作用,E值和线路工频电压下降到较小的稳态值,称为稳态工频过电压. 空载长线路引起的工频过电压图1为l公里的空载长线路,由于通常l<15ookm,导线容抗大于感抗,电容效应使得线路电压高于电旅电动势E,而且愈往线路末端,电压愈高.离线路末端x公里处的电压U二,以末端电压U为基准,按照余弦的规律下降,可用下式表示 U,=Ueos凡 X. cos^一了s,n^ Ecos护.eos(孟十付) 凡~毗/v,人二耐/v,护二arctgxa/Z式中几为电源等效漏抗;Z为导线波阻抗,。为电源电动势角频率;v为导线波速,km/s.可知x.愈大,l愈大,电容效应和工频过电压愈大。┌─┐│lx│└─┘ 图1空载长线路中的沿线电压分布 不对称接地时的工频过电压线路中的不对称接地故障可使线路电压更加升高。令x公里处无故障时的三相对称电压为U认。、认B0、Uxco,在该处A相接地时,健全相的电压U二。和U‘为 U二。=U,。。十改了,Uzc=U式。十仗了仗少二一U,^ok一1k+2’ Z,。介=二井 乙月式中乙。和乙,分别为从故障点向外看去的零序和正序人口阻抗。 在B、C两相接地时,故障点的A相电压为Uz^二Uz^。 3kZk+l k值愈大,健全相电压愈高,在110kV及以上中性点直接(有效)接地的高压和超高压线路中,通常有h“1~3。在h~3和不计导线的损耗电阻时.可算出U二。=U式=1·25U!^。,U二人=1.29U二^。。如果考虑导线的损耗电阻,则U祀笋U、。 将故障点电压分解为正、负和零序分量,分别引人序电压的传递系数,可以求出各相的沿线电压分布。通常,最大电压发生在健全相的末端,同时,空载长线路末端故障时的工频过电压最高。降低工频过电压的措施在电力系统中,避雷器的选择决定于连接点最大可能的工频过电压,长线路中的操作过电压则在工颇过电压的基础上振荡产生,因此为了降低雷电过电压和操作过电压,首先应当考虑降低工颇过电压。中国的sookV电力系统一般要求母线和线路侧电压分别不超过(l .3~1.5) Um。在计划性分合闸时,可在电薄容量较小的一侧先分闸.在电派容t较大的一侧先合闸,从而使等值漏抗几和相应的过电压下降。 实际的超高压线路往往较长,工频过电压很高,需在线路上设t并联电抗器以削弱电容效应。图2为电杭器XL接在空载线路末端的情形,最大工频电压U‘发生在离末端配公里处,并按余弦的规律向两侧下降,可用下式表示U.L=Eeos(孟十尹一△又),U‘二U二Leos△又式中△人~站1/v二arctgZ/X。,酬为末端电压。故有u毗
说明:补充资料仅用于学习参考,请勿用于其它任何用途。