说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 关断暂态过电压
1)  turn-off transient voltage
关断暂态过电压
2)  transient over-voltage between switch contactors
开关触头间暂态过电压
3)  transient over-voltage
暂态过电压
1.
For the large generator stricken by the operational over-voltage in power stations,a field-circuit analysis method of transient over-voltage is presented to study the transient over-voltage field-circuit model of large generator.
针对在厂站操作过电压冲击下的大型发电机,建立一种暂态过电压的场路分析方法,研究大型发电机的暂态过电压场路分析模型。
2.
Based on that,the power system of Yangtze River Delta region was used as an equivalent typical multi-infeed HVDC model,and the traditional SCR/ESCR,multi-infeed SCR/ESCR,the multi-infeed interaction factor,and the transient over-voltage were calculated.
对长三角多馈入直流输电系统进行等值,计算了各直流系统的传统短路比/有效短路比、多馈入短路比/有效短路比、多馈入相互作用因子,以及工频暂态过电压,并对淮南—上海特高压交流线路投产的影响进行了敏感性分析。
4)  transient overvoltage
暂态过电压
1.
It will generate the transient overvoltage when the inductive or capacitive load is severed by the vacuum breaker,the reason is introduced in this paper;and methods about suppressing this overvoltage is discussed.
通过分析研究高压真空断路器在切断感性载和容性负载时产生暂态过电压的原因,探讨了抑制过电压的具体措施。
2.
It is concerned what corona will do on the transient overvoltage between contacts of switch.
基于线路的库-伏特性,并用简单的电路模型来模拟输电线路电晕特性,研究了进线开关在额定电压为600kV的MOA保护下触头间暂态过电压。
3.
The occurrence rate of transient overvoltages, the test requirements of electromagnetic compatibility and insulation coordination specified in IEC standards are presented in this paper.
本文针对电子设备中普遍存在暂态过电压这一事实 ,介绍了暂态过电压的发生率和IEC标准中对低压设备做雷电浪涌抗扰性试验的电磁兼容和绝缘配合的要求 ,并给出了一种用于这种试验的电路原理图及方
5)  very fast transient over-voltage(VFTO)
快速暂态过电压
1.
This paper presents the analysis of very fast transient over-voltage(VFTO) in GIS generated by disconnected switch operation.
阐述了气体绝缘开关装置(GIS)中隔离开关操作所产生的特快速瞬变过程(VFT),分析了快速暂态过电压(VFTO)形成的机理、特性及其对GIS本身和相连的电力变压器可能带来的危害。
6)  VFTO
快速暂态过电压
1.
Influence of Opening and Closing Resistor of Disconnecting Switches to VFTO in 750kV GIS;
750kV GIS中隔离开关的分合闸电阻对快速暂态过电压的影响
2.
Insulation failure inside or outside GIS can be caused by very fast transient overvoltage (VFTO) generated during operating disconnectors in GIS.
SF6气体绝缘开关装置 (GIS)中的隔离开关在操作时产生的快速暂态过电压 (VFTO) ,会造成 GIS的绝缘击穿事故。
补充资料:电力系统开断电容负载过电压


电力系统开断电容负载过电压
capacitance switching-off overvoltage in electric power system

  d lon4I xjtong ko}duon dlonrong fUZol gU0dlonyo电力系统开断电容负载过电压(capacitanceswitehing一off overvoltage in eleetrie powersystem)断路器开断电容负载时由于重嫌导致瞬态振荡引起的过电压。电力系统的电容负载有集中参数的电容器组(无功补偿电容器组和滤波电容器)和分布参数的空载线路。 开断电容负载产生过电压的机理如图(a)、(b)所示,在开断电容负载时断路器在电容电流i(t)自然过零时(::时刻)熄弧,此后电容上的电压将维持电源电动势。(t)的幅值Em,断路器电源侧电动势。(t)仍按正弦规律变化,经工频半周波(tz时刻),电源电动势到达一E,,断路器触头间电压达ZEm,可能发生重燃。重燃后电容上的电压Uc(t)从Em过渡至一E.时,将发生角频率。一1/丫厄云的高频振荡,同时伴随有高频电流ic(t)。当振荡电压达最大值一3E.时,高频电流第一次过零[t3],如果此时电弧熄灭,电容上的电压将维持在一3Eo.再经工频半周波,当e(t)为E二时,触头间电压达4E.,可能发生第二次重嫌,使电容上的电压从一3Em过渡至Em,振荡电压最大可达SE.。循此以往,电容上的电压按IE.、3E,、SEm、7E,…规律上升,直至断路器不重嫩为止。实际上,受断路器断口绝缘恢复强度的限制和断路器熄弧、重燃的随机性,以及泄漏或各种损耗的存在,过电压将低于上述分析的数值。武t) ┌────┐┌──┬─────┐ │}、‘、 ││少欠│ ‘l‘ │ │ ││ │ l} │ │ ││ ├─────┤ │ ││ │l‘、+‘轰│ │ │└──┴─────┘┌──┼────┘ │…‘│ └──┘ 开断电容负载过电压的发展过程 (a)等值电路;(b)波形示意 开断电容负载的过电压幅值与中性点接地方式和电源侧母线电容量有关。一般无功补偿电容器组和交流滤波器组的中性点不接地,过电压较高,母线上接有较大电容时能降低被开断电容上的过电压。 限制开断电容负载过电压的主要措施是:①提高断路器刚分时触头间的介质恢复强度,以避免重燃.这是限制开断电容负载过电压的根本措施,超高压断路器已基本上做到了开断空载线路不重燃.但35kV及以下系统开断电容器组的断路器还时有重燃发生,开断电容负载的特性还需进一步提高。②采用金属氧化物避雷器。主要用于保护电容器组,通过进雷器的能量与电容器组的容量紧密相关,随着电容器组容量的增大,要求避雷器的通流能力也要增大,避雷器参数宜通过计算分析来确定。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条