1)  zero-sequence differential protection
零序差动保护
1.
Scheme design of transformer zero-sequence differential protection;
新型变压器零序差动保护方案设计
2.
It is necessary to install zero-sequence differential protection because conventional differential protection is not sensitive enough to grounded fault.
通过分析变压器传统纵差保护在反映接地故障时灵敏度上的不足,论述了装设零序差动保护的必要性。
2)  pilot zero sequence differential protection
纵联零序差动保护
3)  transformer zero-seguence differential protection
变压器零序差动保护
4)  zero sequence differential protection
零差保护
1.
Through on-site commissioning of differential digital protection,compared with normal method,single differential protection,zero sequence differential protection and bus differential protection ratio restraint characteristic test method are analyzed and studied and then,some simple, and practical test method and conventional convenience commissioning methods are given.
通过差动保护装置的现场调试,结合常规的试验方法,对线路分相电流差动、零差保护、母差保护比例制动特性的试验方法进行了分析、研究,给出了一些简单实用的测试方法,并与常规方法进行了比较。
5)  zero-sequence protection
零序保护
1.
Discussion on implementation of zero-sequence protection for transformer;
对变压器零序保护实现方式的探讨
2.
The end earth fault of big power source and long line makes zero-sequence protection appearing serious problem that protecting refused to move because the voltage of zero-sequence is low,and become a new difficult point that zero-sequence protection in practical application.
大电源长线路末端接地故障使零序保护出现因零序电压过低而使保护拒动的严重问题,成为零序保护在实际应用中的新难点。
6)  zero sequence protection
零序保护
1.
Study on the misoperation mechanism of zero sequence protection of grounding transformer on low resistance grounded 10 kV system;
10kV小电阻接地系统接地变压器零序保护误动机理研究
2.
It analysed influence and contermeasure of 10 kV neutral point earthing through minute resistance,and put forwards some ways of minute resistance value choice and zero sequence protection allocation.
分析10 kV中性点经小电阻接地带来的影响及对策,提出了小电阻阻值选择的一些方法及零序保护的配置。
3.
The influence to the bus equivalent zero sequence impendance and zero sequence protection from the different neutral point earthing mode of the transformer s 110 kV side were specifically analyzed.
 讨论了2台Y0/Y0/Δ接线且无绝缘要求变压器的220kV变电站的变压器中性点几种常见的接地方式,并就变压器110kV侧中性点接地方式对母线等值零序阻抗及零序保护的影响做了具体分析。
补充资料:变压器差动保护系统调试


变压器差动保护系统调试
commissioning of the differ- ential protection system for transformer

b ianyaqi chadong baohu xitong tiaoshi变压器睡动保护系统调试(eommissioningof the differential Proteetion system for trans-former)对流入变压器和自变压器流出的两侧电流,经电流互感器检测变换之后进行比较,其电流差值反映出变压器的内部故障情况.根据这一原理,由电流互感器、差动继电器、断路器跳闸机构组成的保护系统称为变压器差动保护系统.当电流互感器的变比和结线方式与被保护的变压器相适应时,变压器正常运行电流及变压器以外的穿越性故障电流不会使差动保护动作.空载变压器接入电源时,电源侧向变压器流入较大的励磁涌流,为减少它对保护系统的影响,消除误动作,变压器差动保护系统中设有速饱和变流器或谐波制动电路。变压器差动保护系统的调试分差动保护继电器的单体调试和差动保护系统模拟试验两个步骤. 差动保护继电器的单体调试变压器差动保护继电器依其结构特点可分为机电型、整流型、静态型等。机电型差动保护继电器由速饱和变流器、电磁动作的执行继电器、换档擂接板等组成,其调试项目主要有:(1)外观检查,插接与机械动作部分的检查和调整。(2)电磁式执行继电器的常规调试。(3)速饱和变流器的特性试验:检查各绕组极性与结线的正确性;测定变流器伏安特性曲线;通入试验电流,测定执行继电器动作时各绕组分档的动作电流安匝数,并将其整定到设计规定的范围内;测定直流助磁特性,即测定相对动作电流。=(‘/i。)和偏移系数K(1/1)间的函数关系。式中,I为速饱和变流器一次侧通入的直流试验电流(A)八为通入直流分量I时速饱和变流器一次侧的交流动作电流(A);i。为未通直流分量时的交流动作电流(A)。(4)在整定位置下测定保护继电器的整组伏安特性,即差动继电器输入差动电流信号安匝数与执行继电器线圈端电压之间的关系,以判别差动继电器工作磁通密度选取是否合适。 整流型差动保护继电器由差动元件和瞬动元件两部分组成。差动元件包括工作回路、比率制动回路、谐波制动回路及直流比较回路。调试项目主要有:(l)工作回路最小动作电流与返回电流的测定,动作电流整定。(2)比率制动回路动作特性试验。给工作回路和制动回路同时通入试验电流,测定继电器产生输出动作时两试验电流数,绘制出它们的函数关系曲线(即比率动作特性曲线),按照保护设计要求对比率动作特性进行整定。在无特殊要求时,两试验电流取同相位电流。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条