说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 纵联负序差动保护
1)  pilot negative sequence differential protection
纵联负序差动保护
2)  pilot zero sequence differential protection
纵联零序差动保护
3)  longitudinal differential protection
纵联差动保护
1.
Analysis and solution of false action of low-voltage reactor longitudinal differential protection equipment;
低压电抗器纵联差动保护误动原因分析及解决方案
2.
Regarding the large generator longitudinal differential protection device of domestic and abroad different manufacturers as the research objects,the paper compares the basic design theory and the operating mode of the two protect device,and then analyzes their characteristics,so as to take references for relay protective members.
以国内外不同厂家的大型发电机纵联差动保护装置为研究对象,对比其中2套装置的基本设计原理、动作方式等,分析其各自特点,为继电保护人员的调试工作提供借
3.
This paper describes the status quo of power supply of the meso-low power supply system,analyzes the reasons for differential protection maloperation of the meso-low power supply system and its treatment,discusses the longitudinal differential protection principles for 10 kV power supply system and points out the necessity of bus-bar protection for 10KV power supply system.
阐述了中低压供电系统的供电现状,分析了中低压供电系统差动保护误动原因及处理对策,讨论了10 kV供电系统的纵联差动保护原理,提出了10 kV母线保护的必要性。
4)  differential pilot protection
纵联差动保护
1.
The design applied to the differential pilot protection of transmission line with HDLC protocol shows that it has powerful capability of com.
该系统首次使用华北电力大学最新开发研制出的光电流互感器,并在HDLC位同步通信协议的基础上实现了输电线路的纵联差动保护,同时兼具强大的通信能力和抗干扰能力,并可扩展与其它保护、控制装置和调度联网以共享全系统数据、信息和网络资源的能力,为未来的系统扩展留下了广阔的空间。
5)  same directional negative sequence relay
同序负序方向纵联保护
6)  pilot negative sequence directional protection
纵联负序方向保护
1.
Operational experiences indicate that when a high resistance ground fault occurs on one of two parallel double-circuit lines under the strong-magnetic and weak-current operation condition,the pilot zero sequence directional protection of the non-fault line may mal-function while the pilot negative sequence directional protection will not.
通过实例分析说明平行双回线路在强磁弱电联系运行方式下,一回线路末端发生高阻接地故障时,非故障线路纵联零序方向保护会误动,而纵联负序方向保护不会误动,提出在使用纵联零序方向保护切除高阻接地故障的保护装置中,增加纵联负序方向保护,退出纵联零序方向保护以防止误动的发生,并讨论了纵联负序方向保护新方案,方案增加负序电抗继电器和负序电流、电压闭锁,并带小延时动作,从而确保平行线之一故障时,非故障线路纵联负序方向保护不会误动,而故障线路发生高阻接地故障时,纵联负序方向保护能带小延时可靠切除故障。
补充资料:电流差动式纵联保护


电流差动式纵联保护
current-differential pilot protection system

d lonllu Chodongshl Zongllorl boohLJ电流差动式纵联保护(。urrent一differentialpilot proteetion system)利用被保护线路各端电流量实现电流差动原理的一种线路纵联保护。 原理在不考虑本线路导纳的条件下,当正常运行与外部故障时各端流人(由母线流入本线路)电流的代数和为零;内部故障时上述和电流为流人故障分支的总故障电流。据此判别故障是发生在被保护线路内部或外部。 特点①以和电流为动作判据,可靠、灵敏,能确切地判定故障区间。②利用制动特性,使电流差动元件的动作值大于本线路外部故障时因两端电流互感器误差而产生的最大不平衡电流值,以可靠地防止外部故障时的误动作。制动特性有最大电流制动与各端电流绝对值之和制动两种方式.无制动时的最小动作值应大于本线路电容电流值。 制动特性可以用本线路各端流人与流出电流的坐标系表示。如图所示,为电流差动元件制动特性示意图。本线路正常运行与外部故障时流人电流与流出电军韧田嘴流相等,其轨迹为一45。直线。位于理想的外部故障线两侧的虚线,是考虑各端电流互感器误差后,外部故障时流人电流与流出电流的实际可能极限位置。为保证外部故障时不动作,电流差动元件的动作区应在两虚线的外侧实线区域内。理想的外部故降线流入电流电流差动元件制动特性示意图 电流差动式纵联保护一般设有反映电力网发生故障的起动元件,用以增加整套保护的安全性。这种保护适用于各种电压等级的线路。 主要类型①综合电流差动方式。将各端输人的三相电流变成单一的综合电流的差动方式,用于短线路的导引线保护.②分相的电流差动方式。因占用较多的频道,故需与频分制微波通信设备复用,或以光纤通道传输。 发展趋势电流差动原理早已在发电机、变压器与母线继电保护中得到普遍采用。但由于传输通道所限,很长一段时期内在线路保护中只在短线路上用于导引线保护。随着微波通信在电力系统中的使用,20世纪70年代模拟式分相电流差动纵联保护开始在超高压线路上实用。80年代初开发了数字式分相电流差动纵联保护,有较强的自适应能力,安全可靠性高,运行维护方便,在国外有的电力系统已得到普遍采用。配合光纤通信的发展,可以预计.它也将是中国220 kv及以上电压超高压线路的一种重要继电保护方式。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条