1) earth of casing
外壳接地
1.
It simply introduces the technique of GIS,represents the aspects should pay attention to in field application of GIS from the setting,earth of casing and so on,and puts forward the problems need perfecting and solving,to do best to decrease the imperfect link and operating incipient fault in design and increase the design quality.
对GIS技术进行了简单介绍,从安装、外壳接地等方面阐述了GIS在现场运用中应该注意的事项,并提出了一些有待完善及解决的问题,以尽可能减少设计中的不完善环节及运行隐患,提高设计质量。
2) dead tank circuit breaker
外壳接地断路器
3) outer covering
外壳
1.
The questions of testing outer covering injection mold are stated, analysis on the reason and the mold structure is improved.
叙述了外壳注射模在试模中出现的问题,分析了问题产生的原因并改进了模具结构。
2.
The small explosion-proof electric appliance outer covering guards against the explosion of the important parts in the electric equipment.
小型防爆电器外壳是防爆电器设备中重要的防爆部件,其品质状态直接关系到厂矿企业的生产安全。
3.
This paper expounds the structure design of flameproof outer covering of combined switch and analyzes the structure.
阐述了组合开关隔爆外壳的结构设计,并对其结构进行了分析,该结构加工简单、操作方便,进一步提高了煤矿井下采煤工作面的自动化程度。
4) case
外壳
1.
Brief Talk on General Specification of National Military Case Standard;
国军标外壳总规范之琐谈
2.
Structure analysis of adapter case for ball impact based on ANSYS/LS-DYNA;
基于ANSYS/LS-DYNA的电源适配器外壳耐钢球撞击性的分析
3.
The article presents the mechanical properties and features of a new case material for the box-type substation-glass fiber reinforced cement.
文章介绍了一种新颖的箱变外壳材料—玻璃纤维增强水泥的机械性能及其特点,该材料及其制成的箱变在国内具有较好的推广应用前景。
5) shell
外壳
1.
Injection mould design for mobile telephone shell;
手机外壳的注射模具设计
2.
Both the drawing characters of stainless steel and the forming technology character of its linker shell are analyzed, and the technology calculations are completed, the key points of continuous drawing layout and die design are stressed and stated.
分析了不锈钢拉伸特性及连接器外壳成形工艺特点,并进行了工艺计算,重点阐述了连续拉伸排样与模具设计要点。
3.
Synopsis:This paper analyzes problems encountered in the manufacture of billet mould shell.
分析小方坯结晶器外壳制造中遇到的难点问题。
6) enclosure
外壳
1.
By the theory of material mechanics,the stress situation of mining flame-proof electrical apparatus enclosure is analyzed,and the method of design is introduced.
运用材料力学原理,对矿用隔爆型电气设备外壳进行受力分析,详细介绍了矿用隔爆外壳的设计方法。
2.
This article gives a brief introduction on the sco pe of application of UL674 and the discussion on the specifications of the structur al parameter, materials for the enclosure and its thickness, wiring connecting m ode for the motor enclosure used in Division 1, classified location in this stan dard.
简要介绍了美国安全标准UL 674的适用范围 ,并详细论述了标准中对用于 1级危险场所电机外壳的结构参数、外壳材料与厚度、现场布线连接方式的规定。
参考词条
补充资料:电力系统中性点接地变压器接地
电力系统中性点接地变压器接地
earthing transformer for neutral grounding
d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。