说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 低压加热器
1)  low pressure heater
低压加热器
1.
Energy saving in draining of low pressure heaters;
低压加热器疏水方式节能讨论
2.
Reason analysis of water chamber shell vibration for a mixed-type low pressure heater and its handling method;
某混合式低压加热器水室壳体振动原因分析和处理措施
3.
Modification of frequency control for draining system of low pressure heaters of 300 MW turbogenerator set and its benefit analysis;
300 MW汽轮机低压加热器疏水系统变频改造及效益分析
2)  low-pressure heater
低压加热器
1.
This paper gives an introduction on the principle and function of water level controller for low-pressure heater vapor-liquid two-phase fluid in thermal generator set.
介绍了火力发电机组中低压加热器汽液两相流水位控制器的原理、功用。
2.
In the light of cavitation phenomenon in a condensate pump,the structure of the condensate pump,leakage of low-pressure heater and backwater heating process were checked and analyzed.
针对凝结水泵出现的汽蚀现象,从凝结水泵结构、低压加热器的泄漏、回水加热流程几个方面进行了逐步检查与分析,找出了凝结水泵汽蚀的根源,采取了相应的措施。
3.
The causes of drain blockage existing in drainage system of low-pressure heaters no.
对华能威海电厂引进型300MW机组7、8号低压加热器(低加)疏水系统长期存在的疏水阻滞原因进行了分析,并根据现场条件制定出合理的改造方案。
3)  LP heater
低压加热器
1.
The comparison of 4 schemes indicates that the optimized configuration scheme for LP heater drainage system of 1 000 MW extra supercritical turbine should be as follows: No.
4种方案的比较表明,1 000 MW超超临界汽轮机低压加热器疏水系统的优化配置方案是:6号低压加热器设疏水泵、7号和8号低压加热器设内置式疏水冷却段。
2.
In this paper, the type and mechanism of erosion of condenser and LP heater at steam side and at water side were introduced.
介绍了凝汽器和低压加热器的汽、水侧的腐蚀类型和机理,从亚临界、超临界、空冷和核电机组运行参数的要求出发,给出在某一特定情况下换热管采用不锈钢材质的原由和发展方向;乃至冷却水的现状———高度工业化带来的严重污染及对给水水质的苛刻要求,尤其是超临界机组防止铜的析出、空冷机组与铝制散热器的电化学腐蚀等诸方面详细论述了换热管采用不锈钢材质更是势在必行。
4)  tube plate for the low-pressure heater
低压加热器管板
5)  the copper tube of low-pressure heater
低压加热器铜管
6)  inner low pressure heater
内置低压加热器
1.
In order to lessen flow resistance of throat of condenser and ensure stability or equality of flowfield, through numerical simulation by computer, this paper studied optimal place of inner low pressure heater in throat of condenser.
从减小凝汽器喉部汽阻和保证喉部流动的稳定性和均匀性出发 ,通过计算机数值模拟 ,对内置低压加热器的布置方式进行了优化研究。
补充资料:低压厂用变压器


低压厂用变压器
step-down station transformer

d一ya ehongyongb旧nyoql低压厂用变压器(step一down station transfor-mer)向低压(3 80V)厂用电系统供电的变压器。 火电厂内的低压厂用变压器具有下列应用特点:①低压厂用变压器宜采用D,Yn的接线,使变压器有较小的零序电抗,以便于低压中性点的引出经电阻接地或直接接地;②采用无激磁调压方式,调压范围为士5%;③变压器的阻抗应能将低压侧的短路电流限制在制造厂可提供的厂用低压开关柜的允许值内,并当最大电动机起动时,其低压母线电压应不低于允许水平.④低压厂用变压器有油浸式和干式两种,油浸式冷却方式为ONAN,一般用于户外。用于户内时,当油t大于100kg时要装在防爆小间内;干式变压器(参见彩图擂页第34页72图)则用于户内可与低压开关柜布t在一起,应采用F级绝缘或更高等级的绝缘,并具有良好的防潮和阻燃性能。干式变压器的冷却方式可为AN或AN/AF(自然冷却/强迫风冷),视变压器的容t而定,变压器AN/AF的容量比一般不低于1:1.33,当装有防护外壳时,其额定容量不应下降,干式变压器的外壳和外壳防护等级应与低压开关柜相一致。变压器利用小时高时宜选用节能型变压器。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条