说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 单相配电变压器
1)  single-phase distribution transformer
单相配电变压器
1.
Application instance and energy conservation benefits analysis of single-phase distribution transformer;
单相配电变压器应用实例与节能效益分析
2.
When the second-phase reconstruction of rural electric power network carried out,a new low-voltage power supply mode was adopted,that the secondary winding of a single-phase distribution transformer connected to the loads by bundle insulation conductors consisted of two lines and one neutral and separated from each other by insulating materials.
针对我国农村地区供电负荷分散、用电量小的特点,研究以低压侧中间带抽头的单相配电变压器,配合两火一零三芯集束导线低压供电的新模式,并在赤峰市敖汉旗进行了试点。
2)  three-phase distribution transformers
三相配电变压器
1.
Based on the result that transformer can transform travelling waves effectively,this paper researches the transform characteristic of travelling waves in three-phase distribution transformers.
在已经证明配电变压器能有效传变行波信号的基础上,本文对三相配电变压器的行波传变特征进行了研究。
3)  single-phase transformer
单相变压器
1.
Power saving experiment on high voltage sodium lamp supplied by single-phase transformer;
单相变压器供电的高压钠灯降压节电试验
2.
The application of 10 kV single-phase transformer in urban power distribution network is introduced through the examples, the major performance of single-phase and three-phase transformer is analyzed,as well as the comparison of them is conducted in terms of the low voltage line loss,power supply reliability and economic benefit.
通过实例阐述了10 kV单相变压器在城区配电网中的应用情况,分析了单相变压器与三相变压器的主要性能,从低压线损、供电可靠性及经济效益等方面对三相变压器与单相变压器进行了比较。
3.
Generator neutral grounding used the single-phase transformer between generator neutral and ground early in domestic.
二滩水电站水轮发电机组从通用电气加拿大公司引进,发变组保护由ABB公司提供,在国内较早采用了发电机中性点经单相变压器接地方式,并与定子绕组单相接地保护相配合,迄今运行良好。
4)  single phase transformer
单相变压器
5)  distribution transformer
配电变压器
1.
Reason on lightning disturbance of distribution transformer and preventive measures;
配电变压器雷击损坏原因及防止措施
2.
Design and Implementation on Visual Monitoring and Control System for Distribution Transformer;
可视化的配电变压器运行监控与分析系统的研究与实现
3.
A new method for the selection of distribution transformer type and capacity;
一种配电变压器型式及容量选择的新方法
6)  power distribution transformer
配电变压器
1.
The chemical composition,magnetic properties,characteristics and heat treament of amorphous alloy Metglas 2605SA 1 of Allied Signal Inc USA used for power distribution transformers are introduced,analyzed and reviewe
介绍分析并评述了美国AlliedSignal公司于 1999年公开的用于配电变压器铁芯的最新非晶合金 ,Metglas 2 6 0 5SA - 1牌号的具体成分、性能特点及热处理方
2.
This paper probes into the method for selecting the power distribution transformer, the capacitance reactive compensation and the capacity of the diesel generating set in the building s electrical design, and puts forward some problems needing attention.
探讨了建筑电气设计中配电变压器、电容无功补偿和柴油发电机组的容量选择方法,提出了需要注意的问题。
3.
Overload of power distribution transformers is becoming an outstanding problem that impacts safe operation of power distribution grids.
配电变压器过负荷现象日益突出,严重影响着配电网的安全运行,文章分析了配电变压器过负荷的原因,提出了有效的解决方案,并在实践中取得了良好的效果。
补充资料:农村配电变压器台(室)


农村配电变压器台(室)
rural distribution substation

nongCun Peld,anb一anyaqlto.(sh一)农村配电变压器台(室)(rural distributionsubstation)由10 kv/0.38 kv配电变压器、高低压配电设备及附属建筑物构成的农村电力网中最末一级变配电设施,35 kV/0,38 kV农村配电变压器台又称直配变台。其功能是把中压(1。kV)或高压(35kV)变为可供用户直接使用的低压,并对低压配电线路实行保护和控制,一般建在负荷中心附近。 中国农村配电变压器台(室)将逐步实现标准化,淘汰高能耗配电变压器等设备,采用适合农村负荷及环境特点的新装备。例如,农村专用低压配电箱、成套式配电装t、全户外成套式变台、低铁损节能型配电变压器等。采用进口及国产非晶合金铁芯制成的低铁损配电变压器已分别于1990年在甘肃天水、1991年在河北琢州市农网投人运行,情况良好,在解决造价离的问题后有推广前景.20世纪末,节能效果较好的511型卷铁芯配电变压器已引起人们的重视。 构成农村配电变压器台(室)由配电变压器、高压配电设备、低压配电设备和附属建筑物等四部分构成。 (l)配电变压器的功能是传送电能和降低电压.通常选用1台变压器,少数企业或县城变电室选用2台及以上配电变压器。配电变压器容量考虑五年期的负荷发展。(2)高压配电设备有避雷器和高压开关电器。前者的功能是防雷保护,后者的功能是对配电变压器运行进行保护和控制。当配电变压器容量在560 kv·A以下时,高压开关电器一般采用高压跌落式熔断器对配电变压器内部短路进行保护.也可以选用熔断器和负荷开关进行保护。当配电变压器容量大于560 kV·A时,高压侧一般用高压断路器和隔离开关进行保护。 (3)低压配电设备主要有配电箱、计量装置、漏电总保护器和低压避雷器。其功能分别为对变压器及出线的运行进行保护、控制与监测,计量电能和对配电变压器进行防雷保护。配电箱内装有电压表、电流表(有时加装有功功率表、无功功率表)、进线总保护开关电器和各条出线回路的开关电器。315 kV·A及以下配电变压器一般可用低压熔断器和隔离刀闸作为总保护,容量超过315 kV·A的选用低压断路器保护。低压侧总保护具有过负荷和过流保护功能。当采用熔断器保护时,熔体额定电流按变压器允许过负荷倍数和熔体的熔断特性确定。当采用低压断路器时,过负荷保护为延时动作,动作电流根据变压器低压侧允许过负荷电流确定;过流保护为瞬时动作,动作电流为变压器低压侧额定电流的6~8倍。各出线回路的保护动作应与总保护相配合,保证保护动作的选择性。计量装置为电能表箱,有时加装防窃电的设施。在雷电活动频繁的地区,低压侧加防雷设备。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条