1)  bulb tubular pumping station
灯泡贯流泵站
2)  bulb tubular pump
灯泡贯流泵
1.
Numerical study of 3D flow in a bulb tubular pump system;
灯泡贯流泵装置的三维流动数值模拟
2.
The method was applied to measure the hydraulic losses of inlet and outlet conduit of bulb tubular pump system of the pumping station re.
采用本文的方法对某泵站前置灯泡和后置灯泡贯流泵的进、出水流道分别进行了模型试验,测试了流道水力损失。
3.
According to the selection of pump models in the Huai-an fourth pumping station and the Huai-yin third pumping station of the eastern route of South-to-North Water Diversion, vertical axial flow pumps and bulb tubular pumps are compared and studied in the low-lift-head pumping station,and their selecting ranges are put forward on the basis of current conditions.
针对南水北调东线工程淮安四站、淮阴三站泵型比选,对低扬程泵站选用立式轴流泵和灯泡贯流泵进行了选型对比研究。
3)  power station of bulb tubular type turbine
灯泡贯流式电站
1.
Aiming at the characteristics of low head and large discharge of power station of bulb tubular type turbine,the station unit s boundary equations and the boundary equations between draft tube outlet and downstream channel inlet are established in this paper.
针对灯泡贯流式电站水头低、流量大的特点,作者建立了水轮机的边界方程和尾水管出口与下游河道入口的边界方程,对甩负荷后机组及下游河道的水力过渡过程做了联合计算,实现了电站水力过渡过程计算研究中将水力与机械、有压流与无压流统一分析。
4)  bulb tubular pump
灯泡式贯流泵
1.
CFD calculation for large-scale bulb tubular pump;
大型灯泡式贯流泵CFD计算
5)  bulb tubular pump system
灯泡贯流泵装置
1.
With the characteristics of smooth flow patterns in the inlet and outlet conduits, less hydraulic loss and high system efficiency, a bulb tubular pump system is especially suitable for pumping stations of the East-Route South-to-North Water Transfer Project.
灯泡贯流泵装置具有进、出水水流平顺流畅、水力损失小、装置效率高等特点,特别适合于南水北调东线泵站工程,具有较大的应用价值和发展潜力。
6)  bulb tubular pump-house
灯泡贯流泵房
1.
A dynamic time-history analysis of pump-house of Huaiyinsanzhan Pumping Station caused by the flow is made to calculate the dynamic response of bulb tubular pump-house.
根据测点的脉动压力时程,构造整个流道的脉动压力场,通过三维有限元数值模拟对淮阴三站泵房进行了水力振动时程分析,计算了新型的灯泡贯流泵房的动力响应。
补充资料:泵站测流


泵站测流
flow measurement in pump station

bengzhan eeliu泵站测流(flow measurement in pumpstation)现场直接测定单台水泵的流量及泵站总流量。为鉴定水泵的性能,监视、调节、控制水泵运行工况提供准确的流量值。配合其他有关参数的测量,可为泵站节能、技术改造、经济运行及总结建站经验提供科学的依据。 单泵流量的测定,通常的方法可以用管式流量计、测量流速的仪器或各种型式的堰槽等在管道内或明渠水流中进行。测量流量的方法,应该根据具体条件进行选择,但总的原则应该是采用结构简单,性能可靠,价格便宜,易于维修保养的设备。泵站测流技术分为标定测量和监视测量两种。前者采用标准方法准确地测定流量值,用以标定测流设备,后者可作为泵站正常运行监测流量的固定设备以下介绍几种泵站测流的方法。 差压测流法通过测量管道不同断面之间的压力差来确定流量的方法。在紊流状态下,压差h的平方根与流量Q成正比,可以用方程式Q一k了h来表示如果通过标定测量确定了系数k,在正常运行时,就可以通过观测压差值来确定水泵的流量。例如:对于带有进口叭喇管的中小型轴流泵,可以利用喇叭管的收缩压差;对于带有规则弯头的中小型水泵装置,可以在普通弯头的内外侧按要求钻测压孔,并在现场标定差压流量系数,或者把原来的弯头更换为经过实验室标定流量系数的量水弯头,.配上水柱差压计,即可简便地测定水泵流量;对于大型轴流泵,混流泵,贯流泵或大型离心泵,如果采用肘型、钟型或收缩型进水流道,可视具体情况采用收缩压差或弯道压差测宁水泵流量。其流量系数应在现场进行标定。而压差的测量既可直接用水柱差压计在现场直接观测,也可以用流量差压变送器将流量信号输送到控制室,实行自动检测、调节和控制。或者两者同时采用,以备差压变送器出现故障时,仍可观视g记录水泵的运行工况。 均速管测流法将一根开有许多小孔的小管(又称笛形管)插入被测的流道内,并使孔口正对来流方向,这时小管所测得的能头是包括管道内静压和流速水头的全压头,如在测量断面附近的管壁上引出静压测压孔,把两根测压管连接到水柱差压计,根据测得的差压,即可计算平均流速,进而计算通过被测管道的流量。这种方法的优点是设备简单,操作方便,匀速管的流量系数可以自行标定。 超声波流量计利用超声波在水体中顺流传播与逆流传播速度差的关系求出被测流体的流速。