说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 快速暂态过电压
1)  VFTO
快速暂态过电压
1.
Influence of Opening and Closing Resistor of Disconnecting Switches to VFTO in 750kV GIS;
750kV GIS中隔离开关的分合闸电阻对快速暂态过电压的影响
2.
Insulation failure inside or outside GIS can be caused by very fast transient overvoltage (VFTO) generated during operating disconnectors in GIS.
SF6气体绝缘开关装置 (GIS)中的隔离开关在操作时产生的快速暂态过电压 (VFTO) ,会造成 GIS的绝缘击穿事故。
2)  very fast transient overvoltage
快速暂态过电压
1.
Comparison and analysis between test and numerical simulation of very fast transient overvoltage;
快速暂态过电压试验与数值模拟对比分析
2.
Characteristic of very fast transient overvoltage and its influencing factors in EHV GIS
超高压GIS内部快速暂态过电压计算及其影响因素
3.
With the enhancement of gas-insulated switchgear (GIS) running voltage and SF6 pressure, the very fast transient overvoltage (VFTO) due to the operation of disconnecting switch is becoming increasingly serious, which causes faults of the main transformer connected with the GIS and other problems.
随着全封闭气体绝缘组合开关(GIS)运行电压和SF6气压的提高,因隔离开关操作引起的快速暂态过电压(VFTO)也日益明显和严重,引起与GIS相连的主变故障及其他问题。
3)  very fast transient overvoltage(VFTO)
快速暂态过电压
4)  very fast transient over-voltage(VFTO)
快速暂态过电压
1.
This paper presents the analysis of very fast transient over-voltage(VFTO) in GIS generated by disconnected switch operation.
阐述了气体绝缘开关装置(GIS)中隔离开关操作所产生的特快速瞬变过程(VFT),分析了快速暂态过电压(VFTO)形成的机理、特性及其对GIS本身和相连的电力变压器可能带来的危害。
5)  very fast transient over-voltage
快速暂态过电压
1.
Calculation of very fast transient over-voltage in GIS and its distribution in transformer windings;
GIS中快速暂态过电压及其在变压器绕组中电压分布的计算
6)  very fast transient overvoltage
特快速暂态过电压
1.
The Study on Transformer in Gas Insulated Substation Influenced by Very Fast Transient Overvoltage;
快速暂态过电压对气体绝缘变电站变压器影响的研究
2.
In GIS, the switching of a disconnector will produce very fast transient overvoltage (VFTO), which could damage the insulation of GIS and other connected equipments (such as transformer) and produce electromagnetic interference into low voltage control systems.
气体绝缘金属封闭开关设备(GIS)中隔离开关的操作会产生特快速暂态过电压(VFTO),可能导致GIS本体及其相连的设备(如变压器)绝缘损坏,并可能产生电磁干扰,影响二次设备。
3.
In order to study the very fast transient overvoltage(VFTO)distribution in taper winding of pulse transformer(PT)under high-frequency voltage surge of steep front,a distributed line model of PT s secondary winding is built based on multiconductor transmission line(MTL)theory.
为了研究在陡波前、高重复频率的电压冲击下,脉冲变压器(PT)锥形绕组中的特快速暂态过电压(VFTO)分布特性,建立了基于多导体传输线(MTL)理论的PT二次绕组分布参数模型;利用锥形绕组结构上的特性,提出一种有限元法(FEM)和插值公式相结合的方法以快速计算锥形绕组的感应系数矩阵K;通过求解频域下的电报方程可得到绕组的对地电压分布以及匝间电压分布;进行了绕组暂态电压的测量,从实验结果可以看出电压分布的一定规律,并分析了造成计算与实验结果间误差的原因;结合实验提出一种改善电压分布的措施,对大功率PT二次绕组的绝缘设计有一定的参考意义。
补充资料:电力系统特快速瞬态过电压


电力系统特快速瞬态过电压
very fast transient over voltage in electric power system,VFTO

  后才能熄灭,结束一次重嫌过程。随着触头距离的不断加大,击穿电压增加,过电压幅值也逐渐增大,一直到触头间的电压不再超过击穿电压时结束重嫌过程。图中Um为最大过电压幅值。┌─────┬─────────┐│灿头分开 ├─────┐/r/ ││ l │、一厂 │ ││ l │ 、 │ ││瓜笋粉 │ 、 │ ││ │ 、 │ ││ │ 、 │ ││ │ 、│ │└┬────┼─────┼───┤ │/ │ │ I │ └────┘ │ I │ │, │ │I │ └───┘ 特快速瞬态过电压产生的示意图 隔离开关触头运动速度较低,一次操作过程中有可能发生数十次甚至数百次重嫩过程。类似的特快速瞬态过程也可在GIS隔离开关合小电容电流时产生。 VFTO一般不超过2.op.u.,有的可达2,5 p.u.,极少达到3.0 p.u.。VFTO水平的平均值,一般低于雷电冲击耐受水平.对采用GB3ll.1一1997和IEC71一1(1993)标准规定的倾定绝缘水平的缺陷的Gls绝缘不起周值作用. 特快速瞬态过电压的波前陡度与隔离开关触头间的电场均匀程度、电极间隙距离、气体性质和压力大小以及Gls的结构等因素有关。一般其初始前沿在3~Zoon,之间。GIS中SF。气体具有很高的绝缘强度,触头间的击穿距离相对较小,这种情况下发生击穿时,触头两端电压可在数纳秒时间内突然下降,使注入的阶跃波具有极高的陡度。 实际隔离开关操作多次重嫌引起的整个瞬态过程是由GIS中各不同节点的折射波和反射波的盛加而形成的,过电压波形要比上述的更为复杂。 特快速过电压对Gls内部绝缘的影响与SF。气体在陡波作用下的绝缘耐受能力有关。陡波前过电压的波前时间以纳秒计,比标准蓄电冲击波的小得多。SF‘气体在陡波前过电压作用下的绝缘性能还与波的极性有关,而且击穿电压的分散性很大。对于有缺陷的SF。绝缘系统,可能由于电极表面凹凸不平造成电场不均匀,在这种情况下绝缘耐受陡波前过电压的能力将下降很多。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。