1)  switching overvoltage
操作过电压
1.
Analyses of the transient process ab out the the switching overvoltage generated by the open-phase no-load transform er cut by the 10kV vacuum load switch;
10kV真空负荷开关切断非全相空载变压器产生操作过电压暂态过程的分析
2.
Adopting line surge arresters to suppress switching overvoltages in 750 kV EHV transmission lines;
750kV沿线多组避雷器限制操作过电压研究
3.
Idea of increasing only one group of arrester installed along line replacing with parallel resistance in breakers to suppress switching overvoltage in 750 kV transmission line is realized in this paper.
为满足操作过电压设计限值的要求而使用合闸电阻存在诸多缺点,针对西北电网新建750 kV输电线路过电压水平,对沿线增设1组避雷器取代合闸电阻的想法进行了研究。
2)  switching over-voltage
操作过电压
1.
Field-circuit Analysis of Switching Over-voltage for Power Stations;
厂站操作过电压的场路综合分析
2.
Study of new method for on-line safety monitoring in motor switching over-voltage;
电机操作过电压在线安全监测的新方法理论分析
3.
Effect of neutral grounded by low reactance to the switching over-voltage for Gongboxia transformer;
公伯峡变压器中性点经小电抗接地对线路操作过电压的影响
3)  operating over-voltage
操作过电压
1.
Based on the analysis of the operating over-voltage of mine power system, the parameter identificationmethod for operating over-voltage is presented and the identification model is given.
在分析煤矿井下供电系统操作过电压的基础上,提出了对操作过电压进行参数辨识的方法并给出辨识模型。
2.
It emphatically anaylses advantages and shortcomings of several types of popular protection instruments of over-voltage, and advances the protection methods of vacuum circuit breaker′s operating over-voltage.
结合案例分析,简单介绍了真空断路器操作过电压的类型及其产生的机理,重点分析了目前流行的几种过电压防护装置的优缺点,提出了真空断路器操作过电压的防护措施。
3.
To offer the basis for revising national standard GB 50227—1995“Design specification of shunt capacitor installation”, the research on three special subjects, harmonic suppression countermeasures, operating over-voltage protection, capacitor and capacitor bank protection, was carried out.
为了给修订国家标准GB50227—1995《并联电容器装置设计规范》提供依据,有关单位先后对谐波抑制对策、操作过电压保护、电容器和电容器组保护3项专题进行了课题研究,文章对3项专题研究的概况、主要内容、研究结论,以及研究成果在工程中的推广应用等作了简要介绍,并对此3项专题进行的深入研究提出了建议。
4)  operating overvoltage
操作过电压
1.
Analysis of operating overvoltage and re-breakdown after arcing for vacuum switch;
真空开关操作过电压和弧后延时重击穿问题分析
2.
In this article analysis is carried out according to operating overvoltage of vacuum breaker and the overvoltage of circuit under different loads; at the same time corresponding technical measures are proposed from reducing chopping current level, installing absorber, protector and arrester to prevent operating overvoltage.
分析了真空断路器的操作过电压和不同负载回路的过电压 ,并从降低截流值 ,装设吸收器、设置保护器、避雷器等方面提出了防止操作过电压的技术措施。
3.
Analysis the cause of producing operating overvoltage of vacuum circuit breaker, a method of restricting operating overvoltage.
分析了真空断路器的操作过电压产生原因,探讨了限制操作过电压的方法。
5)  operating over voltage
操作过电压
1.
The paper describes the harm of the operating over voltage to high-voltage motor in terms of the operating over voltage mechanism.
操作过电压产生机理出发,阐述操作过电压对高压电动机的危害,通过对高压电机在各种情况下操作过电压的探讨分析,指出高压电动机采用传统起动方式存在的问题,分析了高压电动机采用软起动的必要性,通过对当前各种软起动装置的比较,提出了选择依据。
2.
The paper elaborated the common over voltage type in medium voltage power network-the forming reason and developing mechanism for operating over voltage and ferro-resonance over voltage, and some kinds of effective solving scheme were presented.
文章还阐述了中压电网中常见的过电压类型———操作过电压和铁磁谐振过电压的形成原因和发展机理,提出了几种行之有效的解决方案。
6)  switching overvoltage distribution along line
操作过电压沿线分布
补充资料:电力系统操作过电压


电力系统操作过电压
switching overvoltage in electric power system

  d}an}、x ltong eoozuo gtlod、onyo电力系统操作过电压(switehing overvolta罗in eleetrie power system)电力系统中的故障和操作导致暂态或瞬态振荡而产生的过渡过程过电压。暂态振荡的全过程围绕着操作后的暂时过电压(如工频过电压)进行,其振荡幅值的大小决定于操作前的初始电压和操作后的暂时过电压。忽略回路损耗时.操作过电压幅值~(暂时过电压一初始电压)+暂时过电压。即操作过电压的幅值为2倍暂时过电压与初始电压的代数和。操作过电压幅值与系统最高工作相电压幅值之比称为操作过电压倍数。 操作方式和故障形式的多样性决定了操作过电压的不同类别,主要有:中性点不接地系统中的弧光接地过电压(见电力系统弧光接地过电压),空载线路的合闸过电压(见电力系统合闸过电压),空载线路、空载母线和电容器组的分闸过电压(见电力系统开断电容负载过电压),空载变压器、电抗器和电动机的分闸过电压(见电力系统开断电感负载过电压),不对称接地或系统失去稳定引起的长线解列过电压(见电力系统解列过电压)。 由于影响操作过电压的因素很多,且具有随机性,因此,操作过电压的大小遵循统计分布规律。在绝缘配合设计时,一般取概率曲线中2%处的过电压值(大于此过电压的概率为2%)进行配合,称为统计过电压。 系统中性点的接地方式对操作过电压的影响很大。在中性点非直接接地的系统中,中性点位移现象会导致很高的过电压(可达4倍相电压左右)。中性点直接接地的110~22okv系统的过电压值一般小于3倍相电压。超高压长线路中的过电压值可能很高,除用并联补偿设备限制工频过电压外,尚需采用专门措施限制操作过电压值,如采用金属氧化物避雷器和断路器的并联电阻等,以使过电压值降至2.。~2.5倍相电压以下。不同类别的操作过电压的波头时间和持续时间差别很大。弧光接地过电压的持续时间较长,一般以秒计;空载线路分闸过电压的波头时间短,以徽秒计,持续时间可达数十毫秒;空载变压器分闸过电压的波头时间范围很宽,与变压器的特性和接线有关,一般以徽秒计,变压器至断路器有电缆接线时,可以达到以毫秒计;空载线路合闸和长线解列过电压的波头时间从几十微秒到以毫秒计,持续时间一般几十毫秒,带高压并联电抗器的线路,过电压衰减可能很慢,持续时间可达数百毫秒;而金属封闭气体绝缘开关设备(GIS)操作空载母线时,可产生电力系统特快速瞬态过电压,其波头时间为纳秒级。它们是确定超高压电气设备的操作冲击耐受电压的主要依据。
  