说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 操作过电压及其抑制
1)  switching overvotage and its being restrained
操作过电压及其抑制
2)  overvoltage and its countermeasures
过电压及其防护
3)  operating over-voltage
操作过电压
1.
Based on the analysis of the operating over-voltage of mine power system, the parameter identificationmethod for operating over-voltage is presented and the identification model is given.
在分析煤矿井下供电系统操作过电压的基础上,提出了对操作过电压进行参数辨识的方法并给出辨识模型。
2.
It emphatically anaylses advantages and shortcomings of several types of popular protection instruments of over-voltage, and advances the protection methods of vacuum circuit breaker′s operating over-voltage.
结合案例分析,简单介绍了真空断路器操作过电压的类型及其产生的机理,重点分析了目前流行的几种过电压防护装置的优缺点,提出了真空断路器操作过电压的防护措施。
3.
To offer the basis for revising national standard GB 50227—1995“Design specification of shunt capacitor installation”, the research on three special subjects, harmonic suppression countermeasures, operating over-voltage protection, capacitor and capacitor bank protection, was carried out.
为了给修订国家标准GB50227—1995《并联电容器装置设计规范》提供依据,有关单位先后对谐波抑制对策、操作过电压保护、电容器和电容器组保护3项专题进行了课题研究,文章对3项专题研究的概况、主要内容、研究结论,以及研究成果在工程中的推广应用等作了简要介绍,并对此3项专题进行的深入研究提出了建议。
4)  switching overvoltage
操作过电压
1.
Analyses of the transient process ab out the the switching overvoltage generated by the open-phase no-load transform er cut by the 10kV vacuum load switch;
10kV真空负荷开关切断非全相空载变压器产生操作过电压暂态过程的分析
2.
Adopting line surge arresters to suppress switching overvoltages in 750 kV EHV transmission lines;
750kV沿线多组避雷器限制操作过电压研究
3.
Idea of increasing only one group of arrester installed along line replacing with parallel resistance in breakers to suppress switching overvoltage in 750 kV transmission line is realized in this paper.
为满足操作过电压设计限值的要求而使用合闸电阻存在诸多缺点,针对西北电网新建750 kV输电线路过电压水平,对沿线增设1组避雷器取代合闸电阻的想法进行了研究。
5)  switching over-voltage
操作过电压
1.
Field-circuit Analysis of Switching Over-voltage for Power Stations;
厂站操作过电压的场路综合分析
2.
Study of new method for on-line safety monitoring in motor switching over-voltage;
电机操作过电压在线安全监测的新方法理论分析
3.
Effect of neutral grounded by low reactance to the switching over-voltage for Gongboxia transformer;
公伯峡变压器中性点经小电抗接地对线路操作过电压的影响
6)  operating over voltage
操作过电压
1.
The paper describes the harm of the operating over voltage to high-voltage motor in terms of the operating over voltage mechanism.
从操作过电压产生机理出发,阐述操作过电压对高压电动机的危害,通过对高压电机在各种情况下操作过电压的探讨分析,指出高压电动机采用传统起动方式存在的问题,分析了高压电动机采用软起动的必要性,通过对当前各种软起动装置的比较,提出了选择依据。
2.
The paper elaborated the common over voltage type in medium voltage power network-the forming reason and developing mechanism for operating over voltage and ferro-resonance over voltage, and some kinds of effective solving scheme were presented.
文章还阐述了中压电网中常见的过电压类型———操作过电压和铁磁谐振过电压的形成原因和发展机理,提出了几种行之有效的解决方案。
补充资料:电压波动和电压闪变抑制


电压波动和电压闪变抑制
suppression of voltage fluctuation and flicker

  d ianyabodong he dianyashan bion yizhi电压波动和电压闪变抑制(suppression。fvoltage fluetuation and flieker)冶金工厂中的电弧炉、大电动机、大电焊机等工作时,负荷电流的大幅度增减,引起电压急剧变化,其变化速度大于每秒。.2%,此时出现电压调幅波中的最高电压与最低电玉均方根值之差,称为电压波动。电压波动和有时伴随产生的电压闪变导致用电设备运行不稳定,照明闪烁,影响正常生产、生活甚至人身健康。因此,须对电压波动和闪变进行抑制,使其控制在允许范围内。 在中国按国家标准(GB12326一90)规定,电力系统公共供电点的电压波动允许值为:10kV及以下为2.5%,35~110kV为2.0%,220kV及以上为1.6%。在冶金工厂内部(非公共供电点),按本行业的有关规定,当电弧炉和轧钢大电动机由单独变压器供电时,其用电电压波动允许值可放宽到5%以内。 在电弧炉的熔化期,冲击性无功负荷产生快速的电压波动,使照明灯光发生闪烁,引起人的视觉疲劳而使情绪烦燥,还可能导致电视荧屏监控图像不稳、精密电子仪器工作不正常等。此种人的眼睛对于灯闪的主观感觉称为闪变。对闪变的程度,以对人的眼睛最为敏感的loHz频谱的等效闪变电压值△V10的大小来衡量和评价,按国家标准(GB12326一90)规定,电力系统公共供电点的允许△V10推荐值为:照明要求较高的白炽灯负荷为0.4%,一般性照明负荷为。,6%。 其抑制措施是:(l)对于轧机主传动的冲击性负荷,设计时采用减少电网感抗,以提高供电点的短路容量;或利用自备发电厂发电机,大型同步电动机(如高炉电动鼓风机)进行跟踪补偿;或将两个以上的冲击负荷在时间上错开;或设立单独的静止型动态无功补偿器等加以解决。后者有晶闸管开关电容器式(TSC)、晶闸管控制电抗器式(TCR)、晶闸管控制高阻抗变压器式(TCT)、自饱和电抗器式(SSR)、可控饱和电抗器式(CSR)、复合式(TCR十TSC)和自激变换器式(SVG)等多种类型。(2)对于电弧炉冲击性负荷,设计时采用减少电网感抗以提高供电点的短路容量;或设置单独的静止型动态无功补偿器等加以解决。由于电弧炉在熔化期三相负荷经常不平衡,闪变剧烈,要分相进行控制。要求补偿器响应速度快(全过程的响应时间应小于1个周波)参设计通常采用TCR、SSR、TCT和TCR二TSC等几种静止型动态无功补偿器。 (张炳炎)
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条