1) SF6 circuit breaker
SF6断路器
1.
The electric field of 550kV SF6 circuit breaker with different opening stroke has been calculated and analyzed using the finite element method (FEM).
以550kV单断口SF6断路器为研究对象,采用有限元法对断路器灭弧室空载开断全程不同开距下静电场进行数值计算与分析。
2.
The arc nozzle of SF6 circuit breaker is thought as the kernel of arc quenching chamber,because of its controlling effect on gas flow property during the breaking process.
该文以252kVSF6断路器为研究对象,研究了改变喷口喉部下游仰角、长度对灭弧室吹弧气体流动特性、介质强度恢复特性的影响;应用激波理论和拉伐尔喷口中流速与截面比的关系,研究了局部"放-收"型面及2段型面对吹弧气体的控制作用及对介质强度恢复速度的影响;比较了在不同的喷口尺寸及型面下介质强度的恢复速度,得出喷口下游的型面对开断过程中介质强度恢复速度影响显著的结论。
3.
According to the technical requirement of 800 kV tank SF6 circuit breaker and aiming at the initial structure of bushing of circuit breaker,the numerical calculation of electric field and analyses of insulating performance were conducted based on the technical and engineering conditions.
以800 kV罐式SF6断路器为主要研究对象,根据超高压断路器产品的技术要求,针对断路器出线套管初步设计结构,在满足产品技术条件和工程要求前提下,进行基于电场数值求解绝缘性能分析。
2) SF 6 circuit breaker
SF6断路器
1.
According to test it em of SF 6 circuit breaker,the paper analyzes the process of finding a hidden fault.
最后,结合现行预试规程的有关规定,对SF6断路器的预试项目提出了建议。
2.
This article an alyzes the common faults of SF 6 circuit breaker in service by examples,and proposes some solutions.
从具体案例出发,对SF6断路器常见故障进行了分析,并提出了解决问题的方法。
3.
I n this paper,the influence of ambient temperature and humidity on the moisture c ontent in SF 6 circuit breaker is analysed,the solutions intended to reduce the influence are presented.
5型SF6断路器中微量水分的影响及造成该影响的主要原因,进而提出了控制和减小环境温度和湿度对SF6断路器中微量水分影响的措施。
3) SF_6 circuit breaker
SF6断路器
1.
The FA and LW6 series of SF_6 circuit breakers have been running in the Phoenix Hill,Yuxian and Shuanghe substatuions over 20 years.
FA系列和LW 6系列SF6断路器在凤凰山、玉贤和双河变电站运行已经20余年。
2.
Several common factors influencing the operation of SF_6 circuit breaker have been introduced and some suggestions have been proposed.
对影响SF6断路器运行的几个常见因素进行了介绍,并提出了一定的建议。
3.
SF_6 circuit breakers LW11-220 and ABB HPL245 manufactured by Shenyang High Voltage Switchgear Works experienced faults such as drawbar break,automatic closing and failure to close when used in Shaoguan Power Plant.
介绍了沈阳高压开关厂LW11-220和ABB HPL245两类SF6断路器在韶关发电厂使用中出现的拉杆断裂、自动合闸、拒合等故障。
4) SF6 breaker
SF6断路器
1.
Because the adverse natural environment of high altitude area,most LW13-363 type SF6 breaker often appear movement resistance phenomena of air pressure switch.
由于高海拔地区恶劣的自然环境,西宁供电局330 kV变电站大部分LW13-363型SF6断路器经常出现空气压力开关拒动现象。
2.
Because SF6 gas produces part of liquidation under super low temperature, SF6 gas density decrease inside SF6 breaker, reduce switch and insulate level of SF6 breaker, which can t guarantee SF6 breaker reliable operation.
由于SF6(六氟化硫)气体在超低温条件下产生部分液化,使得SF6断路器内的SF6气体密度下降,降低了SF6断路器的开关能力和绝缘水平,无法保证高压SF6断路器的可靠运行;为此,提出了采用混合气体,或者采用加热SF6气体的方法,解决高压SF6断路器在严寒地区可靠运行的问题。
3.
This paper summarizes the general situation of vacuum breaker development, and comparison of vacuum breaker with SF6 breaker is analyzed.
简述了真空断路器的发展概况,对真空断路器与SF6断路器进行了对比分析。
5) GL 312 SF6 circuit breaker
GL312型SF6断路器
6) SF_6 pot breaker
SF6罐式断路器
补充资料:磁吹断路器
利用磁场的作用使电弧熄灭的一种断路器。磁场通常由分断电流本身产生,电弧被磁场吹入灭弧片狭缝内,并使之拉长、冷却,直至最终熄灭。磁吹断路器的触头在空气中闭合和断开。
分类 磁吹断路器按磁吹原理分为电磁式和电弧螺管式两类。
电磁式磁吹断路器利用分断电流流过专门的磁吹线圈产生吹弧磁场将电弧熄灭。这种结构需要专门设置磁吹线圈和磁极板等元件,其结构比较复杂,笨重,分断性能也较差,在早期的磁吹断路器中曾广泛采用。串联磁吹线圈的熄弧原理在低压直流磁吹断路器中也被采用。
电弧螺管式磁吹断路器出现于20世纪60年代。其原理是利用绝缘灭弧片和小弧角(装在灭弧片下端的U形钢片)将电弧分割,形成连续的螺管电弧,并产生强磁场,从而驱使电弧在灭弧片狭缝中迅速运动,直至熄灭(见图)。这种断路器三相装在一个手车式底架上,配用一个操动机构。合闸时,由动、静主触头快速接通导电回路;分闸时,电弧在动、静触头之间产生,在流经触头回路的电流磁场和压气皮囊产生的作用下,被转移到大弧角上。此时,在辅助系统的磁场驱动下,电弧继续迅速向上运动,当到达小弧角时,电弧被分割成相互串联的若干短弧,这些短弧在电流磁场和小弧角磁性的推拉作用下,很快进入狭缝,形成一个直径不断增大的螺管电弧。这种断路器结构较简单,体积较小,重量较轻,分断性能高。
特点 磁吹断路器以大气为介质,用耐热陶瓷或云母玻璃作灭弧片,电气寿命长,能适应频繁操作的场合。在分断过程中,电弧电阻迅速增加,可以改善功率因数;产生的过电压最小,分断特性优良。其额定电流和分断电流较大,可适应电网发展的需要,分断电流现已达60千安。磁吹断路器运行安全,维护方便。但与其他断路器比,其结构复杂,体积大,成本高,一般只适用于20千伏以下的电压等级。
分类 磁吹断路器按磁吹原理分为电磁式和电弧螺管式两类。
电磁式磁吹断路器利用分断电流流过专门的磁吹线圈产生吹弧磁场将电弧熄灭。这种结构需要专门设置磁吹线圈和磁极板等元件,其结构比较复杂,笨重,分断性能也较差,在早期的磁吹断路器中曾广泛采用。串联磁吹线圈的熄弧原理在低压直流磁吹断路器中也被采用。
电弧螺管式磁吹断路器出现于20世纪60年代。其原理是利用绝缘灭弧片和小弧角(装在灭弧片下端的U形钢片)将电弧分割,形成连续的螺管电弧,并产生强磁场,从而驱使电弧在灭弧片狭缝中迅速运动,直至熄灭(见图)。这种断路器三相装在一个手车式底架上,配用一个操动机构。合闸时,由动、静主触头快速接通导电回路;分闸时,电弧在动、静触头之间产生,在流经触头回路的电流磁场和压气皮囊产生的作用下,被转移到大弧角上。此时,在辅助系统的磁场驱动下,电弧继续迅速向上运动,当到达小弧角时,电弧被分割成相互串联的若干短弧,这些短弧在电流磁场和小弧角磁性的推拉作用下,很快进入狭缝,形成一个直径不断增大的螺管电弧。这种断路器结构较简单,体积较小,重量较轻,分断性能高。
特点 磁吹断路器以大气为介质,用耐热陶瓷或云母玻璃作灭弧片,电气寿命长,能适应频繁操作的场合。在分断过程中,电弧电阻迅速增加,可以改善功率因数;产生的过电压最小,分断特性优良。其额定电流和分断电流较大,可适应电网发展的需要,分断电流现已达60千安。磁吹断路器运行安全,维护方便。但与其他断路器比,其结构复杂,体积大,成本高,一般只适用于20千伏以下的电压等级。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条