说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> SF6互感器
1)  SF6 instructment transformer
SF6互感器
2)  SF6 CT
SF6电流互感器
1.
Expatiates the harm of SF6 CT micro-water over standard, analyzes the cause of SF6 CT micro-water over standard, puts up the control measures of SF6 CT micro-water over standard.
阐述SF6电流互感器微水超标的危害性,分析了SF6电流互感器微水超标的具体原因,提出SF6互感器微水超标的控制措施。
3)  SF_6 gas filled current transformer
SF6气体电流互感器
1.
The operation condition of SF_6 gas filled current transformer including its characteristics and its accident and faults are summarized and analysis.
主要对SF6气体电流互感器的运行情况进行了总结分析,分析了SF6气体电流互感器的特点,SF6气体电流互感器的故障及障碍情况,目前在制造、安装、运行维护中存在的主要问题及预防SF6气体电流互感器事故的主要措施,并对电流互感器今后的技术发展进行了展望。
4)  SF 6 circuit breaker
SF6断路器
1.
According to test it em of SF 6 circuit breaker,the paper analyzes the process of finding a hidden fault.
最后,结合现行预试规程的有关规定,对SF6断路器的预试项目提出了建议。
2.
This article an alyzes the common faults of SF 6 circuit breaker in service by examples,and proposes some solutions.
从具体案例出发,对SF6断路器常见故障进行了分析,并提出了解决问题的方法。
3.
I n this paper,the influence of ambient temperature and humidity on the moisture c ontent in SF 6 circuit breaker is analysed,the solutions intended to reduce the influence are presented.
5型SF6断路器中微量水分的影响及造成该影响的主要原因,进而提出了控制和减小环境温度和湿度对SF6断路器中微量水分影响的措施。
5)  SF6 circuit breaker
SF6断路器
1.
The electric field of 550kV SF6 circuit breaker with different opening stroke has been calculated and analyzed using the finite element method (FEM).
以550kV单断口SF6断路器为研究对象,采用有限元法对断路器灭弧室空载开断全程不同开距下静电场进行数值计算与分析。
2.
The arc nozzle of SF6 circuit breaker is thought as the kernel of arc quenching chamber,because of its controlling effect on gas flow property during the breaking process.
该文以252kVSF6断路器为研究对象,研究了改变喷口喉部下游仰角、长度对灭弧室吹弧气体流动特性、介质强度恢复特性的影响;应用激波理论和拉伐尔喷口中流速与截面比的关系,研究了局部"放-收"型面及2段型面对吹弧气体的控制作用及对介质强度恢复速度的影响;比较了在不同的喷口尺寸及型面下介质强度的恢复速度,得出喷口下游的型面对开断过程中介质强度恢复速度影响显著的结论。
3.
According to the technical requirement of 800 kV tank SF6 circuit breaker and aiming at the initial structure of bushing of circuit breaker,the numerical calculation of electric field and analyses of insulating performance were conducted based on the technical and engineering conditions.
以800 kV罐式SF6断路器为主要研究对象,根据超高压断路器产品的技术要求,针对断路器出线套管初步设计结构,在满足产品技术条件和工程要求前提下,进行基于电场数值求解绝缘性能分析。
6)  SF6 breaker
SF6断路器
1.
Because the adverse natural environment of high altitude area,most LW13-363 type SF6 breaker often appear movement resistance phenomena of air pressure switch.
由于高海拔地区恶劣的自然环境,西宁供电局330 kV变电站大部分LW13-363型SF6断路器经常出现空气压力开关拒动现象。
2.
Because SF6 gas produces part of liquidation under super low temperature, SF6 gas density decrease inside SF6 breaker, reduce switch and insulate level of SF6 breaker, which can t guarantee SF6 breaker reliable operation.
由于SF6(六氟化硫)气体在超低温条件下产生部分液化,使得SF6断路器内的SF6气体密度下降,降低了SF6断路器的开关能力和绝缘水平,无法保证高压SF6断路器的可靠运行;为此,提出了采用混合气体,或者采用加热SF6气体的方法,解决高压SF6断路器在严寒地区可靠运行的问题。
3.
This paper summarizes the general situation of vacuum breaker development, and comparison of vacuum breaker with SF6 breaker is analyzed.
简述了真空断路器的发展概况,对真空断路器与SF6断路器进行了对比分析。
补充资料:电力系统电压互感器谐振过电压


电力系统电压互感器谐振过电压
resonance overvoltage due to potential transformer in electric power system

  南定理,可将三相对地电容等效连接在电撅变压器和互感器的两个中性点之间,由此着出,谐振属于零序性质。无论是电源合闸至空载母线所引起的电压互感器的涌流现象,还是线路中发生对地闪络和熄弧后C。中残余电荷经电压互感器放电所引起的磁饱和现象,都会在一定的C0值下激发起谐振过电压,它表现为电力系统中性点发生位移,并全部反映至开口三角形绕组,引起虚幻的接地故障信号。这是配电网中造成故障最多的一种内部过电压. 图1中性点不接地系统中三相电压 互感器接线图和等效谐振回路(a)三相电压互感导接线图;(b)等效谐振回路 由于谐振的零序性质,导线的相间电容、余弦电容器和传愉的三相有功负荷均对谐振不起作用。 随着C。的增加(即导线增长),将依次发生高频、工频和分频谐振。在很短的空母线合闸时,C0很小,会产生3倍以上的高频谐振过电压。较大的c0则会出现工频谐振过电压,此时一相对地电压很低,其它两相的对地电压接近于线电压,故工频谐振和单相接地现象往往难以区别。当母线上的出线较长时,C。很大将会发生分频谐振,其频率略低于电源颇率的一半,电压表的指针会发生低频摆动,谐振电压分t和开口三角形电压接近于相电压,由于此时谐振频率和相应的励磁感抗减半,互感器趋于深度磁饱和,励磁电流急剧增大,高达额定值的数十倍以至百倍以上,从而造成互感器的发热、喷油以至爆炸。在高频和分频谐振时,三相对地电压同时升高。 可以通过两种途径来抑制上述谐振现象.其一是采取阻尼吸能措施,即在开口三角形绕组两端临时并接一个低值电阻(在6一10kV小电网中,可用200~50ow的白炽灯泡)或将互感器高压中性点经大电阻接地。其二是破坏谐振条件,即人为地增大对地电容使之超过某一临界值,或将开口三角形绕组临时短接,或将互感器高压中性点临时不接地,或将电网改为通过消弧线圈接地。d旧nl一x一tongd旧nyo hugonq一x旧zhen guod{anyo电力系统电压互感公谐振过电压(resonanceovervoltage due to potential transformer inelectrie power system)电磁式电压互感器由于铁芯磁饱和引起的铁磁谐振过电压。在中性点不接地和直接接地电力系统中均有可能发生. 中性点不接地系统中电压互感器的谐振过电压图1中电源变压器的中性点不接地,电压互感器的中性点直接接地,其励磁电感La、L。和Lc分别与导线和母线的对地电容C。相并联而形成谐振回路。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条