1) regulator station
调压站
1.
The problems existing in original Reynold gas regulator station converted from manufactured gas to natural gas are analyzed.
分析了由人工煤气转换成天然气后,原有雷诺式调压站出现的问题。
2.
A testing system of regulator station for compressed natural gas(CNG) is developed based on the LabWindows/CVI software of Natural Instrument company(NI) and the virtual instrument technology.
在分析压缩天然气(CNG)监控系统功能的基础上,采用组态软件技术设计了一种CNG调压站监控系统,给出了系统硬件和软件的设计方法,实现了调压站多项运行参数的实时监测与报警、排气、换热、加臭等系统的自动控制,提高了调压站监控系统的智能化和自动化水平。
3.
The operation parameters of gas regulator station and the common faults of regulator are introduced.
介绍了燃气调压站的运行参数及调压器的常见故障,分析了调压站中常用的4种安全装置——安全阀、安全切断阀、监控器、多功能调压器,探讨了3种安全系统——较简单的安全系统、较经济的安全系统、较安全的安全系统。
2) pressure regulating station
调压站
1.
A viewpoint of simplification and portability for a gas metering and pressure regulating station is proposed.
提出了天然气计量调压站应该简单、轻便的观点,在建设设计中应首先考虑安全、准确、经济和可靠。
2.
In accordance with existing problems in operation,siting of gas pressure regulating station and type selection of regulator are discussed.
针对燃气调压站运行中存在的问题 ,探讨了调压站选址和调压器选型配置。
3.
This paper analyses the problems and status quo on pressure regulating station before gas replacement as well as introduces the technical reform scheme of gas replacement.
分析了置换天然气前调压站现状及存在的问题,介绍了置换天然气中调压站的技术改造方案。
3) CNG regulator station
CNG调压站
1.
Today there is no testing instruments for compress natural gas(CNG) station in our country,so a testing system for CNG regulator station was designed.
系统测试实验表明,该系统具有检测方便、运行可靠、界面友好的特点,可满足CNG调压站各特征参数的测试要求。
4) gas regulator station
燃气调压站
1.
Some problems, such as design scale, regulating process, regulator model selection and ways of reducing investment of gas regulator station are discussed.
探讨了燃气调压站的设计规模、调压流程、调压器选型及降低投资的途径等问题。
2.
From the field instrument process interface, electrical interface to digital interface which communicate with the dispatch center, the article proposes gas regulator station digital ideas, suggestions and examples.
文章从现场仪表的过程接口、电气接口到与调度中心通信的数字接口,提出了燃气调压站数字化的思路、数字接口的建议与示例。
5) selecting melody pressure station site
调压站选址
6) digital pressure regulating station
数字调压站
1.
The article analyzes those frequent problems,discusses the urgency and necessity of generalizing digital pressure regulating station,and puts forward suggestions a.
文章分析调压站数字化过程中经常出现的问题,探讨推广数字调压站的紧迫性和必要性,并提出制订数字调压站有关标准的建议。
补充资料:燃气调压站
城市燃气输配系统中自动调节并稳定管网中压力的设施。燃气调压站按进出口管道压力可分为高中压调压站、高低压调压站、中低压调压站等;按服务对象又分为供应一定范围的区域调压站和为单独建筑物或工业企业服务的用户调压站。燃气调压站内除燃气调压器、管道及其附件外,还设有过滤器、测量仪表、控制装置和安全装置等。过滤器用以清除燃气中的固体悬浮物,保证站内设备的正常工作。站内装有测量燃气温度、压力的仪表。根据需要,有的站内还设燃气计量装置,按照给定条件调节燃气出口压力的装置以及遥测、遥控装置等。保证调压站出口压力不超过规定值的安全防护措施,通常是设置安全放散阀和关闭式安全阀,或将两个调压器串联或并联等,常常是几种方法结合起来使用。
进、出站燃气管道总阀门设于站外一定的距离。主调压器的出口控制压力为出站燃气管道的供气压力,辅助调压器的出口控制压力略低于主调压器的出口控制压力。在正常情况下燃气由主调压器供应。当主调压器失灵,关闭式安全阀动作时,由辅助调压器保证供气。安全放散阀的控制压力要低于管网允许的最高压力。
燃气调压站可以设置在露天、地上的单独构筑物、地下小室、建筑物的一个房间或地下室内,也可以设置在屋顶平台上,对此各国有不同的规定。燃气调压站内的布局应考虑安装、操作和维修工作的方便,调压站建筑应满足防火、防爆要求,要有良好的通风等。
进、出站燃气管道总阀门设于站外一定的距离。主调压器的出口控制压力为出站燃气管道的供气压力,辅助调压器的出口控制压力略低于主调压器的出口控制压力。在正常情况下燃气由主调压器供应。当主调压器失灵,关闭式安全阀动作时,由辅助调压器保证供气。安全放散阀的控制压力要低于管网允许的最高压力。
燃气调压站可以设置在露天、地上的单独构筑物、地下小室、建筑物的一个房间或地下室内,也可以设置在屋顶平台上,对此各国有不同的规定。燃气调压站内的布局应考虑安装、操作和维修工作的方便,调压站建筑应满足防火、防爆要求,要有良好的通风等。