1) revolution dipping method
旋转浸渍法
2) dip-tumbler
浸渍转筒
3) impregnation method
浸渍法
1.
The mesoporous silicas were impregnated by vion solution and calcined in air at 400 °C,the investigation indicated not only vanadium in samples prepared by impregnation method was incorporated into the famework of mesoporous silicas,but also some dispersed spontaneously onto the surface of mesoporous silicas,and formed a monolayer if total amount of V2O5 increased.
采用X射线衍射技术(XRD)考察了金属氧化物V2O5在介孔二氧化硅分子筛上的分散,研究结果表明应用浸渍法将V2O5浸渍于介孔二氧化硅分子筛中,在低于V2O5熔点的适当温度下焙烧后,与未浸渍V2O5样品相比,晶胞参数a值明显增大,说明钒离子掺入了介孔二氧化硅分子筛的骨架中;在一定范围内随着V2O5加入量的增加其在介孔二氧化硅的表面的分散量也在增加,而V2O5残余晶相量远远低于加入的量,说明V2O5掺入介孔二氧化硅分子筛骨架的同时可在介孔二氧化硅的表面成单层分散。
2.
Silica-supported H_3PW_ 12 O_ 40 catalysts were prepared by the impregnation method, sol-gel technique, and sol-gel technique using ionic liquids as the template, respectively, to solve the problems of H_3PW_ 12 O_ 40 such as low surface area, difficult separation, and reuse.
针对H3PW12O40(HPW)的比表面积小和不易回收利用等缺点,分别采用浸渍法、溶胶-凝胶法和以离子液体为模板剂的溶胶-凝胶法制备了HPW/SiO2催化剂,采用傅里叶变换红外光谱、X射线衍射、N2物理吸附和吸附氨的程序升温脱附等技术对催化剂样品进行了表征,并考察了其对苯硝化反应的催化性能。
3.
Eu-doped TiO2 samples were prepared by the sol-gel method,and further doping which uses ammonia as nitrogen source were carried out by the impregnation method.
本文采用溶胶-凝胶法制备了Eu的TiO2粉体,然后以NH3为N源,采用浸渍法进一步对其处理,获得了同时掺杂Eu、N的纳米TiO2。
4) dipping
[英][dip] [美][dɪp]
浸渍法
1.
This experiment studied the influence of sorption by the concentration, the time of dipping and the time of adsorption.
用浸渍法将活性Al2O3、13A分子筛及活性炭制成负载铜离子的负载型吸附剂来吸附煤油中的硫醇类硫。
2.
The sol-gel dipping method has been used to manufacture TiO2-SiO2 multilayer.
报道了用浸渍法制备的TiO2-SiO2选择透过膜和这种薄膜与Fe2O3-Cr2O3-MnO2选择吸收涂层的复合徐层。
5) Dipping method
浸渍法
1.
Silver and praseodymium co-doped titanium oxide[(Ag,Pr)/TiO2]nanometer materials were prepared by the dipping method using Pr(NO3)3.
5H2O]、硝酸银(AgNO3)为掺杂的前驱物,纳米二氧化钛(TiO2)为载体,用表面浸渍法制备了(银,镨)/氧化钛[(Ag,Pr)/TiO2]纳米材料。
2.
Using fiber glass cloth as the carrier,the titania photo-catalyst coated on fiber glass cloth was prepared by the dipping method and the adhesive method.
以玻璃纤维布为载体,分别用浸渍法和黏结剂法制备了负载型TiO2光催化剂,用SEM观察了2种方法中TiO2在玻璃纤维表面的负载情况。
补充资料:旋转-旋转式扫描系统
旋转-旋转式扫描系统
影像学术语。CT设备的类型之一。扫描方式为旋转-旋转式(rotate-rotate,R/R)的CT设备。扫描时X线管和排列成扇形的探测器阵列做同步旋转,属第三代CT机,可用于全身CT检查,是70年代后期以来临床应用的主流机型之一。X线管为旋转阳极,发射大角度扇形线束,探测器多为氙气电离室或为固体探测器,阵列规模通常在数百甚至上千。扫描时间1~4秒。通常具有靶扫描、靶重建、动态扫描、三维成像等特殊程序和多种重建算法、测量分析功能。旋转-旋转式设备在扫描过程中探测器是连续工作的,利用率高,但不能同时进行校准。所获取的每一幅投影轨迹剖面图都是由整个探测器阵列同时采集的信息构成的,个别探测器出现误差便可能使反投影后的重建图像上出现环形伪影(ring artifact)。该型机不具备体积采样能力。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条