1) insulator
[英]['ɪnsə,leɪtə, 'ɪnsjə-] [美]['ɪnsə,letɚ, 'ɪnsjə-]
绝缘层
1.
Study on the red thin film electroluminescent devices with ceramic thick film as insulator layer;
以陶瓷厚膜为绝缘层的橙色电致发光器件的研究
2.
Magnetization property and magneto-impedance of dc Joule annealed CuBe/insulator/NiCoP composite wire;
电流退火CuBe/绝缘层/NiCoP复合结构丝的磁化特性和巨磁阻抗效应
3.
Studies on TFEL Device Using Ceramic Thick Film as Insulator Layer;
以陶瓷厚膜为绝缘层的电致发光器件的研究
2) insulator layer
绝缘层
1.
In the goal to improve this ratio, two insulator layers have been used between the different layers followed by an annealing process at 250℃.
在两磁性层之间加入了绝缘层SiO2,在250℃退火温度下最大阻抗效应为62%。
2.
The ZnO films deposited on insulator layer were characterized by X-ray diffractometry and atomic force microscopy.
用X射线衍射仪、原子力显微镜对生长在绝缘层上的ZnO薄膜进行了表征。
3.
It is reported in this paper that red ZnS∶Sm, Cl thin film electroluminescent devices using ceramic thick film as insulator layer (CTFEL) have been manufactured firstly.
这类显示器的创新表现在采用丝网印刷的几十个微米量级的高介电常数的陶瓷厚膜来替代无机薄膜电致发光器件中的薄膜绝缘层。
3) insulating layer
绝缘层
1.
By analysis one by one,the cause of the accident is confirmed,damage of the insulating layer of the leading wire.
文章通过对因果树图中的9条末端因素进行分析,确认主要原因是由于引线绝缘层损伤。
2.
Ignition of insulating layer of electric wiring is discussed Two models of ignition are developed and their boundary conditions are given Relation between dimensionless electricity β and ignition criteria δcr is analyzed The results of this research are valuable for prevention against electrical fire hazar
分析了输电线路绝缘层电热着火的原因 ,建立了两种着火模型 ,并给出了相应的边界条件。
3.
The old type motor coil winding strain device would destroy the insulating layer,a new type of winding up device is introduced.
过去绕制线圈时用的绕线拉紧装置会破坏绝缘层,介绍了一种新型绕线拉紧装置,该装置可避免刮伤绝缘层,且线圈成型好,大大提高了线圈绕制质量,并改善了生产现场的环境。
4) insulation
[英][,ɪnsju'leɪʃn] [美]['ɪnsə'leʃən]
绝缘层
1.
,Entry Heating Treatment,at the entrance end of the curing pipe so that insulated conductors with large insulation thickness(such as insulated conductors in 220 kV and above EHV XLPE cables) will not have droop insulation during the curing process in the curing pipe.
介绍了在悬链式CCV生产线上生产220 kV及以上超高压电缆绝缘线芯的一种最新技术,即在悬链式CCV生产线的硫化管进端采用特殊的热处理技术———进端热处理技术EHT,使绝缘层较厚的绝缘线芯(如220kV及以上超高压XLPE电缆绝缘线芯等),在进入硫化管硫化交联的过程中可以避免绝缘体的下垂,以提高绝缘线芯的圆整度和同心度,从而使在悬链式CCV生产线上生产超高压电缆绝缘线芯成为一种成熟稳定的技术,这样极大提升了普通悬链式CCV生产线的技术等级。
2.
The crystalline morphology of XLPE insulation on 110 kV power cables was investigated using differential scanning calorimeter(DSC).
通过差示扫描量热法热分析技术,研究了110kV交联聚乙烯绝缘电缆绝缘层的聚集态结构。
6) insulation coating
绝缘涂层
1.
Preparation of Al_2O_3/SiO_2 multiphase insulation coating on electric-heating porous SiC ceramics;
电致发热SiC多孔陶瓷Al_2O_3/SiO_2复相绝缘涂层制备
2.
Through test for performance of insulation coating,it is shown that solong as the Al(H_2PO_4)_3/SiO_2 ratio and specific gravity of the solution were controlledproperly,the excellent insulation coating can be obtained.
通过对绝缘涂层的性能试验,研究了绝缘涂层溶液的比重及Al(H_2PO_4)_3与SiO_2比值对绝缘涂层性能的影响,并由此得出只要适当控制Al(H_2PO_4)_3与SiO_2的比值和溶液的比重,便可获性能优良的绝缘涂层。
补充资料:电力系统绝缘水平和绝缘试验
电力系统绝缘水平和绝缘试验
power systems insulation levels and insulation tests
d lonl一xltong lueyuon shu{P一ng he Jueyuon sh一yon电力系统绝缘水平和绝缘试验(powersystems insulation levels and insulation tests) 绝缘水平系指电力系统绝缘耐受各种作用电压能力的总称。绝缘试验系指在规定试验条件下检验电力系统绝缘强度的各种电压试验的总称。绝缘水平和绝缘试脸,虽是两个独立的概念。但表征绝缘水平是用绝缘电压试验数值来表示的,因而关系又很密切。在一定试验条件下,有限试品上施加少t有限次数的试验电压,由数理统计知识可知,这样得出的绝缘耐受电压值,只能说是“绝缘试验标准规定值”,不是产品绝缘能耐受的电压“真值”。 绝缘水平这个概念,一般地说,是根据现行绝缘配合的计算方法,在采用过电压保护措施条件下,随机的过电压下所发生的故障率限制在运行能够接受的范围内,所要求的(即设计规定的)绝缘应能够耐受的作用电压。通常地,绝缘承受作用电压持续时间愈短,耐受作用电压幅值愈高。 现行试验标准,设计了如下6个在规定条件下进行的用以检验绝缘满足标准耐受电压的绝缘试脸:①长时间工颇电压试验(表征长期运行电压下的绝缘水平,见绝蛛材料寿命试脸、绝蛛交流电压试脸),②短时间(1 min)工频电压试验(仿真暂态过电压含工颇过电压和谐振过电压,见绝蛛交流电压试脸),③操作(25。/2500拌s)冲击电压试脸(表征级波前过电压下的绝缘水平,见绝蛛冲击电压试脸);④雷电(1 .2/50娜)冲击电压试验(表征快波前过电压含雷电过电压和切除空载变压器等类操作过电压下的绝缘水平,见绝缘冲击电压试脸);⑤陡波前(波峰值时间毛0.1邵)冲击电压试验(表征陡波前操作过电压下的绝缘水平,见电力系统特快速瞬态过电压、绝蛛冲击电压试脸);⑥联合电压试验,又称复合电压试验(表征相间或极间过电压下的绝缘水平以及特殊要求工况下的绝缘水平,见绝缘复合电压试脸). 试验的目的,耐受标准规定试验电压值是保证绝缘在运行寿命期内(25年以上)能够耐受长期运行电压和随机过电压下要求的绝缘水平,被长期制造和运行经验证明是可行的。 但研究也表明,随着不同的试品,不同的抽样方法,不同的试验方法(含施压次数不同),可获得不同的绝缘耐受电压值。因此,试品的选取和试验方法是进一步研究的课题。使得绝缘试验“标准规定值”更接近绝缘水平要求耐受电压“真值”。 总之,绝缘强度不是一个“固定值”而是一个随机变童,即在某一电压有一个相应的绝缘击穿概率。施加电压次数多少,对有的绝缘的绝缘强度影响很大.此外,实际运行中电气设备是承受着多应力(电压、太阳辐射、机械负载、温度变化、湿度、污染等)综合作用累积效应。现行绝缘试验方法,用少项组合过应力试验结果来评价,与实际存在差距。对某些绝缘材料(如合成材料)会产生误导,一些国家正在致力研究开发新的绝缘试验方法。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条