说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 理论耐压
1)  theoritic resistance to voltage
理论耐压
1.
By analyzing the ozone cell electrical characteristic,theoritic resistance to voltage,and the ingredients which affect the character of ozone cell,it can be concluded from the result of the experiment and academic analysis that one tubular ozone cell of glass dielectrics will produce ozone more than 100 g / h in expect if only we choose optimized configuration parameter and work condition.
通过对臭氧发生管的电特性以及其理论耐压的分析,讨论了影响臭氧发生管特性的因素。
2)  seakeeping theory
耐波性理论
1.
A discussion on the application of ship s seakeeping theory to navigation;
船舶耐波性理论在航海中应用的探讨
3)  pressing theory
压制理论
4)  roll theory
轧压理论
1.
The article bases on the result of elastic-optic experiment and uses the energy method, roll theory and thick tube theory to calculate the contact pressure in ringent and close section.
根据全息光弹实验结果得出的轧辊接触压力的分布规律,进而利用能量方法、轧压理论及厚壁筒理论对开口孔型、闭口孔型的轧辊接触压力进行计算。
5)  press theory
压榨理论
6)  collapse theory
压溃理论
1.
Based on the collapse theory and a 3D numerical simulation model,the ultimate bearing capacity of reinforced concrete arch ribs was calculated to accurately determine the ultimate bearing capacity of a long-span reinforced concrete arch bridge.
采用压溃理论和三维仿真模型,分析了钢筋混凝土拱肋在几何非线性、材料非线性、几何缺陷以及混凝土压碎、开裂、骨料嵌锁等因素耦合作用下的极限承载力,以使它的确定更符合实际。
2.
The formation of a plastic hinge at its cross section is considered as the limit state of strength of the member; and the stable load bearing capacity of the member is determined by means of the collapse theory.
提出了钢管混凝土偏压柱考虑等效紧箍力的作用,把钢材和核心混凝土均简化成理想弹性塑性体,按截面形成塑性铰确定强度承载力,同时采用压溃理论确定构件的稳定承载力。
3.
On the basis of axially compressed short column experiments, this paper analyzes the M-N- relationship for concrete filled square steel tubular columns through numerical computation and simplified approach , By use of the collapse theory, a simplified analytic method for computing the ultimate strength of concrete filled square steel tubular columns under eccentric compression has been suggested .
在此基础上,提出了用压溃理论计算方钢管混凝土偏压柱极限承载力的简化解析方法,并将其应用于工程轴压柱(因其存在初始缺陷,实际上为小偏心受压)的计算。
补充资料:操作冲击感应耐压试验


操作冲击感应耐压试验
inductive withstanding test with switching impulse

COOzuoch。门gJ}90自yingnolyoshjyo门操作冲击感应耐压试验(induetivo with-standing test with switehing impulse)在电力变压器低压绕组施加操作冲击电压,通过电磁感应使变压器高压绕组的绝缘经受过电压考验的试验。试验所施加的电压波形是模拟电力系统内部由于开关操作或发生故障产生的一种波形,称为操作冲击电压波。根据中国电力行业标准的规定,操作冲击感应耐压试验可应用在变电所现场,对电力变压器进行绝缘考验。由于这种耐压方式省去了大容量的供电变压器,试验装备上可比采用三倍频试验装置施加正弦波电压更为方便。在电力变压器制造厂,对额定电压为3 30 kV及以上电压等级的电力变压器应该进行操作冲击耐压试验。此时,也可采用感应耐压方式。 试验电压波形对变压器类设备(包括互感器以及电抗器)内绝缘所使用的标准操作冲击电压波形如图1所示。Um为电压峰值,Tl为视在波前时间,TZ为 礁电)。9之J’盯0.3到南┌─┬───┐│尹│泣互军│└─┼───┤ │T2 │ └───┘图1内绝缘试验用的标准操作冲击电压波形由视在原点起算到第一次过零时间,T3为90%峰值电压持续时间。规定T3不小于200娜;孔不小于500件s;IEC76一3文件规定Tl不小于20娜,通常不大于250拜S;中国国家标准规定Tl为20一25。尸匀中国电力行亚标准规定Tl不小于20拜S。上述波形与外绝缘耐压和放电所采用的波形有所区别。试验电压波的极性规定为负极性。试验电压峰值u~由有关标准规定。施加的操作冲击电压的次数为三次。 原理接线该试验的原理接线见图2。由直流充电的电容C,,经一对铜球间隙FA放电,向变压器T低压侧施加一操作波。变压器高压侧因电磁感应,按变比升高电压产生试验用的操作波形。调节电图2试验的原理接线阻R:、R:及电容CZ可调节变压器低压侧操作波至合适形状,其高压侧除初始阶段外,波形基本上与低压侧相同。过零时间TZ除与C:电容量有关外,很大程度上取决于变压器非线性的励磁电抗大小,因此与铁芯的饱和程度、剩磁的大小及极性相关。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条