1) capacitance error
电容误差
1.
Due to the use of DIAC and timing capacitance,it overcomes the traditional pulse-train generator\'s unstable pulse number phenomenon caused by capacitance error and temperature change by the use of two timing capacitances.
这种脉冲序列发生器使用了双向触发二极管和单电容定时,因此克服了传统的脉冲序列发生器,由于使用2个定时电容,从而因电容误差和温度变化所引起的脉冲个数不稳定的现象。
2) capacitor error-averaging
电容误差平均
1.
In this paper,the theoretics and operational styles of several significant capacitor error-averaging calibration methods are introduced.
实践表明,电容误差平均技术是消除失配误差的一种有效途径。
2.
The high linearity is realized by using the passive capacitor error-averaging technique to calibrate the capacitor mismatch error,a gain-boosting opamp to minimize the finite gain error and gain nonlinearity,a bootstrapping switch to reduce the switch on-resistor nonlinearity,and an anti-disturb design to reduce the noise from the digital supply.
这些设计技术包括采用无源电容误差平均来校准电容失配误差、增益增强(gain-boosting)运放来降低有限增益误差和增益非线性、自举(bootstrapping)开关来减小开关导通电阻的非线性以及抗干扰设计来减弱来自数字供电的噪声。
3.
In the light of the principle of pipeline ADC, this paper analyzes the error, points out the main reason, introduces digital error-correction technology and capacitor error-averaging technology, and proposes a solution based on these technologies.
从流水线ADC工作原理出发,对误差进行了分析,指出了主要原因,介绍了数字校正技术和电容误差平均技术,并结合数字校正技术和电容误差平均技术提出了解决方法。
3) the inaccuracy of the capacitance of the C2
C_2电容值误差
4) capacitor error averaging
电容误差平均
1.
An improved capacitor error averaging technique was developed to make the conversion more efficient.
电容误差平均技术是一种本质线性(inherentlylinear)的流水线模数转换电容失配校准技术,但其性能指数(分辨率×速度与功耗×面积之比)并不理想。
2.
Passive capacitor error averaging is an inherently linear capacitor mismatch calibration technique for pipelined analog-to-digital conversion, but its conversion speed is halved because of double sampling and double transferring.
无源电容误差平均技术是一种本质线性(Inherently Linear)的流水线模数转换电容失配校准技术,但其转换速度是传统技术的一半。
3.
Thus, this paper introduces a method called Capacitor Error Averaging Technique, which could effectively reduce the negative influence caused by capacitor-mismatch.
在开关电容电路中,电容失配是重要的误差源,鉴于此,本文介绍了一种电容误差平均技术,能够有效的降低电容失配带来的影响。
5) errors of precise capacitors
精密电容器误差
1.
By LAN and MPI,the parallel computating situation is established and the problem of evaluation s errors of precise capacitors is solved In the process,the traditional Runge-Kutta method is enhanced Finally,the factors that influence the efficiency of parallel computing are also discusse
利用局域网和标准消息传递库构成并行计算环境 ,实现了对精密电容器误差的并行计算 ,改进了传统的Runge -Kutta方法 ,最后讨论了与并行计算效率有关的因素。
2.
The network parallel computing environment is established and based on perturbation method for variable boundary problems, the problem of evaluation of errors of precise capacitors is solved with parallel implementation.
基于变动边界微扰法 ,实现了精密电容器误差的并行计算 。
6) capacitor tracking error
电容轨迹误差
1.
Two different models are used to analyzing the impact of capacitor tracking error on DAC s accuracy.
用两种不同的理论模型分析了电容轨迹误差对DAC精确度的影响,并在两种模型下比较了两级和传统的单级电荷按比例缩放DAC的精确度和版图面积。
补充资料:电容式电压互感器暂态误差
电容式电压互感器暂态误差
transient error of capac-itor voltage trans-former
电压,主要来源于为了使正常的二次抽出电压和一次翰出电压同相所专门设t的补偿电抗器,它与分压电容器两者形成振荡回路,在一次电压突变时产生电磁是波一种sookV电容式电压 互感器接线示意图Cll、C12、C13、CI一分压电容导;Ll一补偿电杭界;T一中问变压器;LZ、CZ、RZ一构成阻尼回路的电感、电容 及电阻暂态;也来源于抑制铁磁谐振而在二次端子上并人阻尼回路等的暂态响应.图中是一种实际sookV电容式电压互感器的接线示意图.当一次电压突变时,在这种电容式电压互感器的二次箱出电压中,将出现两种预率的暂态电压:一是频率较高、衰减较快的分t;另一是颇率低,衰减较慢的分盘. 标准国际电工委员会(I EC)推荐标准出版物186对电容式电压互感器的“暂态响应”有如下规定:“当在高压端与地短路情况下,电容式电压互感器的二次电压值应在额定颇率的一个周波内衰减到低于短路前峰值的10%”.这条规定,指的是当一次电压波为零或者是为最大值时发生短路这两种情况中的较大者。dlonrongshld一onyo hugonq一zontol wueho电容式电压互感.曹态误差(transient errorofeapaeitorvolta罗transformer)当一次电压发生突然变化,电容式电压互感器的二次翰出电压中,因出现附加的短时暂态电压而造成的电压传变误差。出现这种现象,是电容式电压互感器的一种固有特性。 影响电容式电压互感器的暂态误差,对装设在弱电派侧(电撅阻抗远大于线路阻抗的短线路上)的瞬时距离继电器的侧t精度,影响很大;同时也影响快速方向继电器在母线故障时的方向判别能力。在这些情况下,继电器安装点故障后的一次工频残余电压很低,或为零,在故障后的短时间内,通人继电器的电压中,哲态分t电压占了极大比重,甚至只有暂态分量电压,从而妨碍这些继电器的正常工作。需要考虑有效措施解决。 由于互感器本身暂态过程的影响,在系统的某些!大操作中,例如空载线路由带电情况下断开然后进行重合闸,无论在第一次断开或重合闸后,装设在线路上的电容式电压互感器的二次输出电压中,将出现许多一次系统中根本不存在的假象,不能如实反映一次电压变化暂态过程的实际情况。 来源电容式电压互感器二次翰出电压中的暂态
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条