1) station power using system connection mode
站用电接线方式
1.
A more reasonable operation mode has been proposed according to the atypical 220kV substation station power using system connection mode.
针对220kV变电站非典型站用电接线方式,提出一种更合理的运行方式。
2) connection mode of service power supply
厂用电接线方式
1.
The connection mode of service power supply directly affects safe operation of generating unit and economic benefits of the power plant.
厂用电接线方式直接影响着机组安全运行和电厂经济效益。
3) splice type of power supply lines
电源接线方式
1.
Proceeding from the practical utilization of UPS in power plant,this article,taking the typical UPS as example,analyses the function of UPS,splice type of power supply lines,estimation of capacity,and use and inaintenance.
从发电厂实际应用出发,以典型UPS装置为例,就UPS的作用、电源接线方式、容量估算、使用维护等方面进行了分析,并给出UPS运行及维护建议。
4) bus system arrangement
电站主接线
1.
The model and algorithm to evaluate bus system arrangements reliability of pumped storage power stations are proposed based on the analysis of the pumped storage power stations characteristics.
在分析抽水蓄能电站主接线特点的基础上,提出了抽水蓄能电站主接线可靠性综合评估的模型和算法,考虑了抽水蓄能机组发电和抽水2种运行工况和电站的多种运行方式,并将可靠性指标通过转移(受阻)电量的损失转化为经济性指标,从而实现了对抽水蓄能电站主接线可靠性的综合评估。
5) mode of connection
接线方式
1.
Practice and ponder on changing mode of connection of rectiformer;
整流变压器改变接线方式的实践与思考
2.
The principles for the mode of connection of whole compensating device and how to choosing the parameter of capacitor and current-limiting reactor are analyzed.
就电容器、串联电抗器的参数选取及整个补偿装置的接线方式进行了原理分析,提出了合理的参数选型方法及正确的接线方式,以确保整个补偿系统的安全可靠运行。
3.
It gives technical characteristics about the construction of capacitive winding, mode of connection and circuit protection in 3phase capacitance lowloss energysaving power transformer.
提供了其中的容性绕组的结构、接线方式以及电路保护等技术特征。
6) wiring method
接线方式
1.
Several DCS-based wiring methods for connection of auxiliary units in medium and small sized power stations into the DCS control system are introduced.
介绍了基于DCS下,中小型电厂辅机接入DCS控制的几种接线方式,分析了各种接入方式的优缺点,提出了今后控制方式的发展方向。
2.
The wiring errors methods of voltage loop will eliminate by multimeter and phase angle table;the wiring methods of electric current loop will judge though moment way or phase volt-ampere way.
电能计量装置错误接线方式有几百种,在实际检查和分析错误接线时,一般都采用"逐步逼近法",即先通过对电压、电流回路的检查,使电压、电流回路发生错误接线的几率大大降低。
补充资料:厂用电接线
厂用电接线
station service power connection
ehongyongd旧nJ一ex旧n厂用电接线(station service power connec-tion)连接水电站厂用电电源、配电设备和负荷的电路方案。它是厂用电系统姐路电流计算以及设备、导体和电缆选择的基本依据,是厂用电系统安装和运行维护的基础资料。 厂用电负待较小、供电距离较短的水电站,通常采┌──┐┌──┐│〕[ ││〕[ │└──┘└──┘图1两级电压厂用电接线简图用0.4 kV一级电压供电,这种接线多用于中小型水电站。厂用电负荷较大、枢纽范围较广、供电距离较远、且有高压厂用电电气设备的水电站,多采用高、低两级供电电压.高压为6kV或10kV,低压为0.4 kV或0.66kV(见图1),引水式的中型水电站,厂房与大坝距离较远,如果厂用电接线只有0.4 kV一级电压,则设专用坝区用电变压器,以6 kV或10kV电压向坝区供电。 厂用电接线墓本要求要求供电可靠、接线简单、经济合理。 (l)供电可靠。主要有3个方面要求:①选用质t合格的厂用电配电设备.②厂用电配电设备上下各级之间保护动作选择性配合合理,不发生故障时越级跳闸。③保证重要的厂用电负荷供电电源可靠,应有两个电源供电,当任一电源故障时,另一电源应能自动切换投人,不影响负荷的连续供电. (2)接线简单。指电源、设备和负荷之间连接清晰明了,尽量简化接线,减少因设备间连接复杂互相影响而增加故障概率,也便于操作维护和管理,减少误操作事故,从而提高厂用电系统的运行可靠性。 (3)经济合理。在技术优越性基本相同的墓础上,力求造价最省。 接线形式水电站厂用电系统都采用单母线接线形式,具有简单、清晰、运行维护方便等特点。高低压厂用电系统的主配电屏接线方式基本有两种:一为单母线分段,每段母线上一般有两个电源供电,可互相切换,互为备用;另一为单母线多分段或单母线多分段环形接线,每一分段母线上接一个电源,并通过分段联络断路器来实现电源的互为备用,如图2所示。为提高大型水电站厂用电电源主配电屏接线的可靠性,要求在任一分段母线检修时,其他分段母线仍应有两个及以上的供电电源,以适应各种运行方式下对厂用电源的要求。