1) valve cooling system
阀冷
1.
Basic analysis on the valve cooling system's switching control problem of Zhaoqing converter station,Gui-Guang HVDC project
贵广直流肇庆换流站阀冷切换控制系统浅析
2) Cold wall slide valve
冷壁滑阀
3) valve-cooling control
阀冷控制
1.
The structure and controlling principles of valve-cooling control system are introduced,including the structure of controlling program and the controlling program and the controlling interface,especially the requirement of main pump operation is indicated.
为利于今后直流工程阀冷系统的运行维护,介绍了阀冷控制系统配置和控制原理,包括控制程序结构和接口。
4) valve cooling system
阀冷系统
1.
A thorough investigation discovered that there was severe corrosion and scaling problem laying in the thyristor valve cooling system.
为了找到天广直流输电工程运行5年后换流阀冷却系统中存在较严重的腐蚀与沉积,形成的垢质阻塞冷却水路进而使元件散热不畅而烧毁直流输电系统故障的成因和解决方法,检验了阀冷系统相关元件材质与水质,依据沉积物成分分析结果并结合电化学反应理论初步给出了阀内冷水系统腐蚀与沉积现象发生的物质基础与过程机理。
2.
HVDC valve cooling system with agent of water is scaling bit by bit during normal operation, and lowering the efficiency of the valve components, this is the reason for regularly removing scale in the system maintenance.
采用水冷却的高压直流阀冷系统,在正常运行过程中会产生水垢,从而影响阀元件的冷却效果,因此,有必要定期对阀冷系统进行水垢清除。
3.
It is found that there is problem of valve cooling system designed in these lines, which may cause misaction and refusal to action.
分析了南方电网中3回高压直流输电系统中的阀冷系统漏水检测与保护功能,发现均存在一定设计漏洞,装置有可能因此出现误动和拒动,建议在天广直流系统以及高肇直流系统的阀冷控制系统中增加判据,使之功能更完善。
5) cold water valve
冷水阀
1.
This article introduces a water-adjusting apparatus,which including its SCM as the core, it can use in many occasions which need to control the temperature, the code tube can display the temperature and the coefficients of water, The SCM can control the cold water valve and the hot water valve according to the temperature signal of water and the high water level and the low water level.
本文介绍一种恒温加热器的设计与开发,系统以单片机为核心,可以适用千各种需要恒定温控的场合,数码管可以显示出水温温度和设置的水温参数,单片机能根据现场水箱的温度信号及上,下水位限信号,自动地控制其冷水阀的开启进行加水,控制加热器的开关得到恒温水。
6) cold start valve
冷起动阀
补充资料:溢流阀、顺序阀、减压阀的比较
溢流阀 | 减压阀 | 顺序阀 | ||
控制油路的特点 | 通过调整弹簧的压力控制进油路的压力,保证进口压力恒定,p2=0 | 通过调整弹簧的压力控制出油口的压力,保证出口压力p2稳定 | 直控式-通过调定调压弹簧的压力控制进油路压力;夜控式-由单独油路控制压力 | |
出油口情况 | 出油口与油箱相连 | 出油口与减压回路相连 | 出油口与工作回路相连 | |
泄漏形式 | 内泄式 | 外泄式 | 内泄式 | |
进油口状态及压力值 | 常态 | 常闭(原始状态) | 常开(原始状态) | 常闭(原始状态) |
工作状态 | 进出油口相通,进油口压力为调整压力 | 进油口压力低于出油口压力,出油口压力稳定在调定值上 | 进出油口相通,进油口压力允许继续升高 | |
联接方式 | 并联 | 串联 | 实现顺序动作式串联作卸荷阀用时并联 | |
功用 | 定压、溢流或安全作用限压、稳压、保压 | 减压、稳压 | 不控制系统的压力,只利用系统的压力变化控制油路的通断 | |
进油腔压力p1控制阀芯移动 | 出油腔压力p2控制阀芯移动 | 进油腔压力p1控制阀芯移动 |