1) operation of isolating switch
刀闸操作
1.
Disturbance caused by the arcing during operation of isolating switch for power carrier channel
刀闸操作电弧对载波通道的干扰
2) switching operation
倒闸操作
1.
Application of rule-based system Jess in electrical switching operation simulation;
基于规则系统Jess的电力倒闸操作仿真系统应用研究
2.
Analyses on synthetic factors influencing electric switching operation in substation;
影响变电站电气倒闸操作的综合因素分析
3.
Exploration and implementation of switching operation licensing mechanisms for power transformation equipment
变电运行设备倒闸操作许可制的探索与实践
4) sluice operation
闸门操作
1.
Selection of a final design is an iterative processinvolving many factors,including the general layout of the project,sluice operation andeffect of tailwater detention.
介绍挖深式消力池程序设计方案,考虑闸门操作方式、下游水深滞后等因素影响,并对收缩水深及其跃后水深、经验数表等问题进行了讨论。
6) handling airlock
操作气闸
补充资料:电力系统倒闸操作
电力系统倒闸操作
switching operation of electric power system
d lonll xltong dooZho Co0ZUo电力系统侧阐操作(switehing。peration ofeleetrie power system)对断路器和隔离开关所进行的投人与退出的操作,包括对相关的继电保护与安全自动装t等所进行的投人与退出的操作。断路器和隔离开关是电气设备连向电力系统的开合元件,通过操作可以改变电气设备的运行状态和电力系统的运行方式(包括事故处理)。倒闸操作是电力系统运行中一项经常进行的重要工作,如果发生差错,会造成电力系统或人身事故,甚至导致电力系统瓦解或人员伤亡,因而必须规定严密的制度。倒闸操作必须在电力系统值班调度员统一指挥下,按照规定操作程序向发电厂、变电所或下一级调度值班人员发布操作命令,然后由以上人员按照命令操作,或者由值班调度员直接进行遥控操作. 倒闸操作目的①电力系统间、发电机与电力系统间的并列与解列.②输电线路和变压器的停电和送电,补偿设备的停用和投人运行(包括对新装设备的充电),③电力网络的合环与解环,④改变母线运行方式,⑤改变变压器中性点接地运行方式.⑥切除或接人负荷.⑦投人或退出继电保护与安全自动装t;⑧对已停电检修施工的设备实施接地及相间短路或解除接地与相间短路;⑨投人与退出调度自动化装t等。 倒闸操作制度操作制度是为保证倒闸操作的正确而建立的,其主要内容有:操作前要考虑和注意的事项,如对功率分布、电压、电力系统频率、继电保护、安全自动装里的影响;根据操作任务,正确书写倒闸操作票,并由值班调度员进行相互审核,按照操作票的步骤在电力系统模拟盘上或在调度自动化的模拟系统上进行预演;发布倒闸操作命令的具体规定(见调度命令)。 一些调度部门已使用计算机编制并打印倒闸操作票,从而减少值班调度员的工作量,降低操作票的差错率和提高操作的可靠性。