1) forced delay commutating
强迫延时换相
1.
After thorough analysis,it is concluded that,due to the relatively large leakage inductance of rectifying transformer and large inductor of the HV filter,the three-phase HV-SRS is forced to work in a fault state of forced delay commutating angle αp=30° and overlapping angle γ≥60° when HV discharge happens and electron beam current (EBC) surges.
通过深入分析,指出其成因是由于高压整流变压器漏感较大和系统采用大电感高压滤波,当高压放电时电子束流剧增,三相桥式整流电路运行于一种强迫延时换相角αp=30°和换相重叠角γ≥60°的故障状态,时间过长必然导致高压整流硅堆热损坏。
2) forced phase shifting
强迫换相
3) mean forced outage duration
平均强迫停运延续时间
4) forced commutation
强迫换流
1.
Forced commutation technology has been analyzed thoroughly,which is the base of DC thyristor switch.
对EAST托卡马克极向场电源系统的关键设备之一——大功率双向直流快速晶闸管开关的基本工作原理,即强迫换流技术进行深入的理论分析,得出直流晶闸管开关可靠关断理论判据。
5) forced reversing
强迫换向
6) compulsive exchange
强迫性交换
补充资料:强迫
1.亦作"强迫"。 2.施加压力使服从;迫使。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。