1) bus bar MOA
母线避雷器
1.
Based on the structure of UHVDC bus bar MOA,a 3-D finite element model was established;the potential and electric filed distribution of the bus bar MOA under the continuous operating voltage was calculated.
分析了恒定电场的计算方法;根据特高压直流母线避雷器的结构,建立三维有限元模型,计算了其在直流持续运行电压下的电位电场分布;结果表明,在直流电压下,避雷器电阻片上承担相同的电压,防晕环的主要作用是降低局部产生过高场强和防止电晕;同时对该避雷器的防晕环进行了结构优化。
2) DC bus arrester
直流母线避雷器
3) line surge arrester
线路避雷器
1.
The Installation ways of line surge arrester and its selection;
线路避雷器的安装方式及选择
2.
To solve the calculation problem of line surge arrester shunting coefficient at line lightning protection,equivalent circuit of line surge arrester acting is built under three lightning damage conditions: direct lightning strike on top of transmission tower and on central span of overhead grounding wire,lightning shielding failure.
为了解决线路避雷器在防雷中的分流系数计算问题,针对雷电直击输电线路的杆塔顶部及档距中央避雷线和雷电绕击导线等三种雷害情况,建立线路避雷器动作时的等值电路,推导出线路避雷器在防雷中的分流系数计算公式。
3.
In order to study the function of line surge arrester at line lightning protection,equivalent circuit of line surge operation had been built considering conditions of straight lightning strike on tower top and round strike to conductor.
为了研究线路避雷器在防雷中的作用,根据雷电直击杆塔顶部及绕击导线两种情况,建立线路避雷器动作时的等值电路,推导出考虑残压影响的线路避雷器对雷电流的分流计算公式。
4) line MOA
线路避雷器
1.
The Analysis and Application of Line MOA on AnHui 220kV Transmisson Line;
安徽电网220kV输电线路安装线路避雷器的分析及应用
2.
Installation of line MOA is an effective measure for decreasing trip-out accident due to lighting stroke on overhead line,enhancing reliability of power supply and reducing service cost.
加装线路避雷器是减少线路雷击跳闸事故,提高供电系统可靠性,进一步降低运行成本的一种有效手段。
5) line lightning arrester
线路避雷器
1.
Some measures to prevent thunderstorm damage are introduced such as adding line lightning arrester,reducing ground resistance of poles and towers,lightning protection for standby .
通过对发生的电网事故的分析,介绍了一些防止雷害的措施:加装线路避雷器,降低杆塔接地电阻,热备用断路器防雷等方面的内容。
6) line arrester
线路避雷器
1.
Abnormal operation analysis of transmission line arresters in Guangdong power grid;
线路避雷器在广东电网输电线路上异常运行情况的分析
2.
Study of application schemes for line arresters based on GIS
基于GIS平台对线路避雷器应用方案的研究
3.
Study on line arrester applied to improve the lightning performance of 10 kV distribution lines
应用线路避雷器提高10kV配电线路防雷性能的研究
补充资料:避雷器
避雷器 surge arrester 能释放雷电或兼能释放电力系统操作过电压能量,保护电工设备免受瞬时过电压危害,又能截断续流,不致引起系统接地短路的电器装置。避雷器通常接于带电导线与地之间,与被保护设备并联。当过电压值达到规定的动作电压时,避雷器立即动作,流过电荷,限制过电压幅值,保护设备绝缘;电压值正常后,避雷器又迅速恢复原状,以保证系统正常供电。
避雷器有管式和阀式两大类。阀式避雷器分为碳化硅避雷器和金属氧化物避雷器(又称氧化锌避雷器)。管式避雷器主要用于变电所、发电厂的进线保护和线路绝缘弱点的保护。碳化硅避雷器广泛应用于交、直流系统,保护发电、变电设备的绝缘。氧化锌避雷器由于保护性能优于碳化硅避雷器,正在逐步取代后者,广泛应用于交、直流系统,保护发电、变电设备的绝缘,尤其适用于中性点有效接地的 110千伏及以上电网。 |
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条