1)  Interline fault without ground
跨线不接地故障
2)  phase to phase fault
不接地故障
1.
This paper analyses the rule of variations measuring impedance of distance relay when phase to phase fault occurs between two lines on double circuit line on the same pole (DLSP).
从理论上分析了同杆并架双回线跨线不接地故障时距离继电器测量阻抗的变化规律。
3)  cross country fault
跨线故障
1.
This paper starts with the different characteristic between simple line fault and cross country fault,new method for identifying simple fault and cross country fault is put forward.
从同杆并架并架双回线跨线故障和单回线故障的不同电气特征出发,分析了现有的主要选相元件在同杆并架线路发生跨线故障时所存在的问题,提出了基于跨线故障识别的同杆并架双回线故障选相的新方案。
2.
After transformation,line protection can select phase correctly when cross country fault occurs,the transmission of protection signals can be more reliable and rapid in optic fiber channel,to provide more.
改造后,线路跨线故障时保护能正确选相,保护信号通过光纤通道能更可靠快速地传输,为500 kV线路更加安全稳定运行提供保障。
3.
There are 120 kinds of faults occurred in double circuit lines, for the existence of the cross country faults.
但是,由于同杆双回线会发生跨线故障,致使同杆双回线的故障种类多达120种,并且同杆双回线的故障计算和分析十分复杂。
4)  crossing-line fault
跨线故障
1.
This paper starts with the different characteristics between simple line faults and crossing-line faults.
从同杆并架双回线跨线故障的特征出发,分析了现有主要选相元件在同杆并架线路发生跨线故障时存在的问题,提出了基于跨线故障识别的同杆双回线故障选相的新方案。
5)  cross-country fault
跨线故障
1.
Although fault component current phase selector has excellent performance for single transmission lines,it may select unwanted phase for cross-country faults in double-circuit lines on a same tower.
相电流差突变量选相元件在单回线故障中具有良好的选相性能,但在同杆双回线跨线故障中可能误选相。
2.
Based on the analysis on the relationship of the positive and the negative sequence impedance, also the positive and negative fault component current under simple and duplicate fault conditions, a cross-country fault identifier is proposed.
通过对线路发生单纯性故障与跨线故障情况下的正、负序故障分量阻抗关系和正、负序故障分量电流幅值关系的分析,提出了一种判别电力系统发生跨线故障的判别元件。
3.
According to a special cross-country fault occurs on certain 220 kV transmission lines,this paper calculates the fault components of current and voltage and analyzes the performance of line protection based on the method of equivalent current and sequence component.
针对某220kV线路发生的一起特殊跨线故障,利用等效电流和序分量法,求解线路故障时的电气量,分析故障时线路保护的动作行为。
6)  inter-line fault
跨线故障
1.
Based on the decoupling transformation,a differential current expression is described for double-circuit line,and the differential current characteristics of all the phases are analyzed for both in-zone simple faults and inter-line faults.
同杆并架双回线两回路间存在耦合,基于解耦变换,推导了行波差动保护应用于同杆双回线的差流表达式,详细分析了区内简单故障与跨线故障时两回路的各相差流特征,研究表明,同杆双回线中区内金属性故障时,由于波速不一致,在健全相引起的不平衡差流较相同长度的单回线更严重,为此提出了相应的措施,给出了行波差动保护在同杆双回线路中的实用方案。
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。