说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 钙的检测方法
1)  Method of Detection Calcium
钙的检测方法
2)  method of detecting selenium
硒的检测方法
3)  better determination method
更好的检测方法
4)  detecting method
检测方法
1.
Summary of detecting methods of keyhole in plasma arc welding;
等离子弧焊接小孔行为检测方法概述
2.
Studies of detecting method on the products of dietetic lampblack purifying equipment;
饮食业油烟净化设备产品检测方法研究
3.
Detecting method of retarding effect of S-type retarder for plaster;
S型石膏缓凝剂缓凝效果的检测方法
5)  detection method
检测方法
1.
Pollution of the L. monocytogenes and its detection method research progress;
单核细胞增生性李斯特氏菌污染及其检测方法研究进展
2.
Advancement in the study of leakage detection method for long-distance oil and gas transportation pipeline;
长输油气管道泄漏检测方法研究进展
3.
Gas pipeline leakage detection method based on micro-wave technology;
基于微波技术的输气管道泄漏检测方法
6)  testing method
检测方法
1.
Field performance testing method research and implementation of elevator limited speed device and security pincers;
电梯限速器安全钳现场性能检测方法研究
2.
The assessment and testing method of foundation reinforcement effect of dynamic compaction;
强夯地基加固效果的评价及检测方法
3.
Miss distance error due to rotation of CCD sensor imaging surface and its testing method;
CCD像面旋转引起的脱靶量误差及检测方法
补充资料:NTC热敏电阻检测方法

一、测量标称电阻值Rt


   用万用表测量NTC热敏电阻的方法与测量普通固定电阻的方法相同,即按NTC热敏电阻的标称阻值选择合适的电阻挡可直接测出Rt的实际值。但因NTC热敏电阻对温度很敏感,故测试时应注意以下几点:   


  1、由标称阻值Rt的定义可知,此值是生产厂家在环境温度为25℃时所测得的。所以用万用表测量Rt时,亦应在环境温度接近25℃时进行,以保证测试的可信度。   


  2、测量功率不得超过规定值,以免电流热效应引起测量误差。例如,MF12-1型NTC热敏电阻,其额定功率为1W,测量功率P1=0.2mW。假定标称电阻值Rt为1kΩ,则测试电流:   


  显然使用R×lk挡比较合适,该挡满度电流Im通常为几十至一百几十微安。例如多用的500型万用表R×1k挡的Im=150uA,与141uA很接近。   
  3、注意正确操作。测试时,不要用于捏住热敏电阻体,以防止人体温度对测试产生影响。


二、估测温度系数αt  


  先在室温t1下测得电阻值Rt1;再用电烙铁作热源,靠近热敏电阻Rt1,测出电阻值Rt2,同时用温度计测出此时热敏电阻RT表面的平均温度t2。将所测得的结果输入下式:   


  αt≈(Rt2-Rt1)/[Rt1(t2-t1)]   


  NTC热敏电阻的αt<0。   


  注意事项:


  1、给热敏电阻加热时,宜用20W左右的小功率电烙铁,且烙铁头不要直接去接触热敏电阻或靠的太近,以防损坏热敏电阻。


  2、若测得的αt>0,则表明该热敏电阻不是NTC而是FTC。