1) metering mechanism
计量装置,计量器
2) Metering device
计量装置
1.
On-line calibration of energy metering device based on high voltage energy meter
基于高压电能表的计量装置在线校验技术
2.
Represent definition,function and development process about the electric energy metering device at the exchange point between the electric plant and the electric company.
阐述电网关口的定义、作用和发展历程,考察关口电能计量装置的构成及其综合误差的来源和计算过程,以此为基础研究关口电能计量综合误差的不确定度评定方法。
3.
The problems of the metering device of the distribution transformer in Longhai rural district are analyzed,and the electric quantity lost caused by those problems calculated.
分析了龙海地区农村配电变压器计量装置存在的问题,对由此产生的电量损失进行了计算;分析了计量装置故障原因,提出了完善农村配电变压器计量装置的措施,并对改造后的农村配电变压器计量装置进行跟踪调查以说明改造效果。
3) metering unit
计量装置
1.
The operational principle of some metering units, such as leadscrew nut mechanism, pendulum bar type metering unit, metering pump, are introduced.
介绍了丝杠螺母机构、摆杆式计量装置、计量泵装置等计量装置的工作原理。
2.
The working principles, properties characters of gear pump and plunger pump——2 kinds of metering units wide used in RIM machine, and the wedged metering unit developed on the base were all introduced.
介绍了RIM机中广泛使用的 2种计量装置———齿轮泵和柱塞泵的工作原理、性能特点 ,以及在此研究基础上开发的楔形计量装
3.
Although the manufacturers are possessed of the set of flowrate computers and flowrate metering unit,the users generally use their own SCADA systems to monitor meters instead of purchasing the dedicated flowrate computers in order to avoid investment, the problem that the flowrate metering unit allocates with SCADA system are proposed.
流量计量及流量标定的过程比较复杂,目前广泛采用流量计算机对流量计量装置进行数据采集、处理。
4) metering installation
计量装置
1.
On the basis of analyzing synthetical errors of electric energy metering installation,puts forward the measures of adopting high voltage metering box measuring electric energy in 35kV and below distribution network,which reduce synthetical errors and prevent stealing electricity.
在分析电能计量装置综合误差的基础上,提出在35kV及以下电压等级的配电网中采用高压计量箱计量电能的措施以减少综合误差和防止窃电。
2.
Watermeter is a metering installation for water-supply enterprises.
水表是供水企业计量装置,水表的选用,水表的安装、维修、校验,水表的抄读管理,直接关系到企业的经济效益和服务质量,加大水表管理力度,是企业的一项重要的基础工作。
5) measuring device
计量装置
1.
Design the measuring device controlled system based on PLC technical,and human-computer interface based on human-machine engineering.
采用可编程序控制技术及人机工程学方法的人机操作界面设计计量装置电控系统,具有结构简单、运行可靠、效率高的特点。
2.
The influence of second circuit and second load of pass measuring transformer on measuring devices are introduced,the errors of voltage transformer under the second load are analyzed specially,the importance of controlling transformer second circuit parameter to reduce integrated errors are explained.
介绍关口计量用互感器二次压降与二次负荷对关口计量装置综合误差的影响,重点分析实际运行二次负荷下电压互感器的误差,说明了控制互感器二次回路参数指标对减小关口计量装置综合误差的重要性。
6) measurement equipment
计量装置
1.
Development of standard measurement equipment for liquid oxygen density;
液氧密度标准计量装置的研制
2.
This paper introduce the gas flow measurement equipment used for the North line and South line of Shanghai Pudong gas manufacturing co.
本文介绍了在浦东煤气制气有限公司南北线煤气流量计量装置的建立过程中,通过选型,对孔板流量计及其布局、流量计算公式和不确定度的研究,利用智能变送显示仪改变了传统孔板流量计量程比的限制,保证了系统的准确度,所采用的计算机技术确保煤气流量计量数据的公正、公平、公开。
补充资料:电能计量装置综合误差
电能计量装置综合误差
over-all error of elec-tricity metering devices
d IOnneng JI}Iong ZhUongzhl Zonghe Wueha电能计,装t综合误差(over一all error ofeleetrieity metering deviees)电能计童装1的电能表误差、测量用互感器合成误差和电压互感器二次回路压降引起的误差的代数和。综合误差的计算公式为 y一yl十入十凡式中y为电能计量装置综合误差,%;y:为电能表误差,%;yZ为互感器的合成误差,环;y3为电压互感器二次回路压降引起的误差,%。 世界各国都对电能计量装置的综合误差规定了限值并采取措施减少综合误差。中国对电能计量装置综合误差限值的规定是:对I类电能计量装置,不得超过士。.7%;对I、I类电能计量装置,不得超过士1 .2%。 电能表误差(yl)见电能表误差。 测t用互感器的合成误差(yZ)由于测量用电流、电压互感器存在比值差(简称比差)和相角差(简称角差),在测量中将引起合成误差。在某些场合,虽然互感器本身的比差、角差都符合要求,但其合成误差可能很大。合成误差的计算公式为,,一丛丛孕二上王xl。。 厂1式中孔为互感器的合成误差,%;K,为电流互感器的额定变比;Ku为电压互感器的额定变比;尸:为互感器一次侧的功率;尸2为互感器二次侧功率. 电压互感器二次回路压降引起的误差(y3)电能表电压线圈接在电压互感器二次回路中,因回路中的电缆、熔断器有电阻和电抗,会造成电压降,所以电能表端电压和电压互感器出口端电压在数值和相位上不一致,这样就造成了电压互感器二次回路压降误差。压降引起的误差的计算式为 尸产一尸___,q-一~一-;二一~X IUU 厂式中y3为电压互感器二次回路压降误差,纬;尸‘为电能表端三相有功功率;尸为电压互感器出口端三相有功功率。 减少综合误差的方法通常采用的方法有: (1)电能表调整时考虑互感器的合成误差,使电能表的误差和互感器的合成误差互相抵消,以减少电能计量装置的综合误差。 (2)根据互感器的误差,合理地组合配对。配对的原则是接到电能表同一元件的电流互感器和电压互感器的比差fv,与f],、fvZ与力2符号相反、数值接近或相等;而它们的角差乙,与凡,、击2与衡2符号相同、数值接近或相等。 (3)根据电能表运行条件合理调表,即根据现场环境温度、季节变化趋势、负荷大小、有无电磁场影响等合理地调表。 (4)对互感器误差进行调整。对运行中的电流、电压互感器,可视现场具体情况进行误差补偿,也可调整某一相或两相的互感器比差和角差,以减少合成误差。 (5)采用专用的计量回路,尽量缩短二次回路长度,加大导线截面,降低导线电阻,以减少电压互感器二次回路压降引起的误差。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条