1) ct input voltage
互感器输入电压
2) sensor voltage input
传感器电压输入
3) potential transformer
电压互感器
1.
Measures preventing from iron core magnetic resonance caused by iron core saturation of potential transformer;
电压互感器铁心饱和引起铁磁谐振的防治措施
2.
Single-phase check methed of potential transformer for on-site check;
电压互感器现场校验的单相校验法
3.
Time-domain measuring method for wide-frequency transfer characteristic ofpotential transformer;
电压互感器宽频传递特性的时域测量方法
4) Voltage mutual inductor
电压互感器
1.
Voltage Mutual Inductor Grounding and Its Function in Transformer Substation;
变电站的电压互感器接地方式及功能
2.
Taking the case of voltage mutual inductor exploration of TYD-110/3-0.
02H电压互感器的爆炸事故为例,对该设备的故障原因进行分析,并对设备的检修试验、采购选型、运行巡视3方面提出了一些预防措施和建议。
3.
Ferromagnetic resonance of voltage mutual inductors for 6 kV power supply system of the oil refinery took place several times, resulting in burn- out of voltage mutual inductors of 6 kV substation, explosion of lightning guards, breakdown of electric equipment, fusing of high voltage fuses and misoperation of relaying protection.
针对炼油厂6kV供电系统运行中多次发生电压互感器铁磁谐振,导致6 kV配电所电压互感器烧毁,避雷器爆炸,用电设备击穿,高压熔断器熔断,造成继电保护误动等问题进行了原因分析,提出了预防措施。
5) voltage transformer
电压互感器
1.
Site test and analysis of 220 kV metrical voltage transformer;
220kV计量电压互感器的现场测试及分析
2.
Analysis of voltage transformer secondary loop grounding point;
电压互感器二次回路接地点分析
3.
Verifying the voltage ratio of voltage transformer (discharge coil) by method of adding the high voltage;
采用高压加压法校核电压互感器(放电线圈)变比
6) PT
[英][,pi: 'ti:] [美]['pi 'ti]
电压互感器
1.
Harm done by the failure of the circuitry PT to the power system;
线路电压互感器故障对系统造成的危害
2.
PT Secondary Circuit Reducing Reform and its Reducing Mothod;
电压互感器二次回路压降改造及减少压降的方法
3.
Analysis and Solution of the 6~10 kV Power Distribution Grid PT Resonance Elimination
6~10kV配电网电压互感器消谐的分析及对策
补充资料:互感器
互感器 instrument transformer 按比例变换电压或电流的设备。互感器的功能是将高电压或大电流按比例变换成标准低电压(100V或)或标准小电流(5A或10A,均指额定值),以便实现测量仪表、保护设备及自动控制设备的标准化、小型化。互感器还可用来隔开高电压系统,以保证人身和设备的安全。分为电压互感器和电流互感器两大类。 电压互感器 按原理分为电磁感应式和电容分压式两类。前者多用于220千伏(kV)及以下各种电压等级;后者则一般用于110kV以上的电力系统,在330~765kV超高压电力系统中应用较多。按用途,电压互感器又分为测量用和保护用两类。①电磁感应式电压互感器。工作原理与变压器相同。基本结构也是铁芯和原、副绕组。特点是容量很小且比较恒定,正常运行时接近于空载状态。电压互感器本身阻抗很小,一旦副边发生短路,电流将急剧增加而烧毁线圈。为此,电压互感器原边接有熔断器,副边接地,以免原、副边绝缘损坏时,副边出现对地高电位而造成事故。电磁感应式电压互感器的等值电路与变压器的等值电路相同。②电容分压式电压互感器。在电容分压器的基础上制成。电容式电压互感器多与电力系统载波通信的耦合电容器合用,以简化系统,降低造价。此时,它还需满足通信运行上的要求。
电流互感器 工作原理、等值电路与一般变压器相同,只是其原边绕组串联在被测电路中,且匝数很少;副边绕组接电流表、继电器电流线圈等低阻抗负载,近似短路。原边电流(即被测电流)和副边电流取决于被测线路的负载,与电流互感器副边负载无关。电流互感器运行时,副边不允许开路。因为在这种情况下,原边电流均成为励磁电流,将导致磁通和副边电压大大超过正常值而危及人身及设备安全。因此,电流互感器副边回路中不允许接熔断器,也不允许在运行时未经旁路就拆卸电流表及继电器等设备。 |
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条