2) reactor cavity
反应堆堆腔
3) external reactor vessel cooling
堆腔注水
1.
Based on an integral system analysis computer code,a severe accident sequence induced by loss of feed water(LOFW) plus failure of auxiliary feed water,with external reactor vessel cooling(ERVC) measure,was calculated for 900 MWe nuclear power plant.
针对900 MW级压水堆核电厂,采用一体化严重事故分析工具,对主给水丧失(LOFW)始发事件叠加辅助给水失效严重事故下,采取堆腔注水(ERVC)缓解措施的事故进程进行模拟,对该措施缓解堆芯熔化进程、保持压力容器完整性的有效性进行分析验证,并对注水速率、注水高度和注水时间对该措施的影响进行了分析。
2.
Making use of an integral systems analysis computer code,a severe accident sequence induced by large-break loss-of-coolant accident(LB-LOCA) at cold leg,with external reactor vessel cooling(ERVC) measure,was calculated for 1 000 MWe nuclear power plant.
针对百万千瓦级压水堆核电厂,采用一体化严重事故分析工具,对一回路冷段大破口冷却剂丧失(LB-LOCA)始发严重事故下,采取堆腔注水(ERVC)缓解措施的事故进程进行模拟,对该措施缓解堆芯熔化进程、保持压力容器完整性的有效性进行分析验证,并对影响该措施的因素进行研究。
4) reactor cavity
反应堆腔
5) cavity reactor
腔式反应堆
6) PWR upper plenum
压水堆上腔室
补充资料:反应堆与堆内构件振动监测
反应堆与堆内构件振动监测
reactor and internals vibration monitoring
fony旧gdu一yu du旧e一gouJ一on zhendong Jlonee反应堆与堆内构件振动监测(reactor andinternals vibration monitoring)用以监测反应堆压力容器及堆内构件的振动。 安装在压力容器上的4个加速度仪(l个在容器顶盖的螺栓上,3个在容器的下封头的堆芯中子侧t的贯穿管上),其信号与容器的加速度振动成正比。 通过采集堆外四个长中子电离室上部第二段和下部第五段的信号,并将其与反应堆功率成正比的平均注量率信号进行标称化处理,送噪声诊断系统,根据每个电离室各段上的差异,以测定堆内构件的振动,并监测异常情况。利用数据库中已有的数据,可以判断引起这种异常的原因。 堆内构件的振型有两种:梁式和壳式。梁式振型用以监侧嫩料组件和吊篮筒体的振动,这种振动改变了堆内构件结构和中子探侧器之间水层的厚度,导致探测器上侧得的中子注量率随上述结构的振动颇率而变化。 壳式振型用以监测堆内构件热屏的振动,这种振动导致堆芯筒体与热屏之间水层厚度的变化,从而影响中子撞击热屏时的能谱。由于热屏对中子的吸收与其能量有关,从而造成中子探侧器上信号的脉动。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条