说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 冷室
1)  cold room
冷室
2)  shock chamber
激冷室,骤冷室
3)  quench chamber
激冷室
1.
The entrainment properties of mixed gas passing through a cistern in quench chamber of Texaco gasifier were investigated by a three-dimensional numerical simulation.
采用三维数值模拟方法对德士古气化炉激冷室内合成气穿越液池过程的流动特性以及合成气带水等关键问题进行了研究,探讨了两管(上升管和下降管)间隙、气流速度以及液膜流速对带液量的影响。
2.
In order to find the pattern of turbulent flow and heat transfer of synthetic gas in the Vertical downward pipe,a numerical model based on analyzing the flow and heat transfer features of the vertical pipe in quench chamber is first presented.
经分析 ,气化炉激冷室结构设计不够合理 。
3.
In this paper,the estimation model of black water recirculating flux within quench chamber is deducted.
本文推导出激冷室内黑水循环流量的估算模型,分析了影响循环量的因素,并提出了工程实施的注意事
4)  quenching chamber
激冷室
1.
Combining with large chemical fertilizer plants,this paper presents the problems occurred in the measurement of the liquid level in Texaco heavy oil gasifier's quenching chamber and the relevant solutions,and describes DCS software configuration and logic treatment scheme.
结合大化肥装置的实例 ,介绍德士古重油气化炉激冷室液位测量中遇到的问题和处理办法 ,对DCS软件组态和逻辑处理方案做了较详细的描
5)  cold roiling at room temperature
室温冷轧
6)  quench section
忽冷室
补充资料:J1512立式冷室压铸机操作规程
最大压铸件(铝合金)重量:1.8公斤
工作循环次数:70-120次/时

1、遵守《铸造设备通用操作规程》有关规定。
2、检查工作液量,必要时添加按说明书规定配制的乳化液。
3、一般不准空压射,如必须空压射时,一定要在压射室中放入软质垫料(如棉线、铅块等),防止损坏设备。
4、按下面次序启动设备,并空试其他动作:
a、接通电源,打开贮压缸伐,压下自动调节杠杆,启动高压泵,当泵运转正常后,放开上述杠杆;
b、打开机器总伐,分别操纵各动作的手柄和踏板,检查各个动作是否正常,确认一切正常之后,方可进行生产。
5、切实注意安全,操作者必须穿戴好劳保用品,不得站在正对压铸分型面部位进行工作,防止铝水溅出,发生烧伤事故。
6、经常观察各种仪表读数是否符合工艺要求,设备的运动是否正常,如发现异常现象,必须立即板动总伐手轮,关闭贮压缸伐或停泵进行检查,必要时通知维修人员修理。
7、经常注意工作液的温升,温度最高不得超过40°С,否则必须强加冷却。
8、设备停歇一小时以上时,必须停机关伐,防止发生设备人身事故和减少动能消耗。
9、工作后,按下列次序停车:设备处于泄压状态时,关泵停车,切断电源,关闭总伐和贮压缸伐。
10、设备清理后,设备的运动部分(如缸杆、导杆、滑轨等)还须涂一层薄机械油。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条