1) start-up feed pump
起动给水泵
2) cold start feed water pump
冷起动给水泵
3) motor-driven feedwater pump
电动给水泵
1.
The unstable operation and the mechanical seal frequent leakage of two motor-driven feedwater pumps in Shaanxi Huadian Pucheng first phase project directly affect the load as well as safe and economy operation.
陕西华电蒲城发电公司一期工程2台电动给水泵运行不稳定。
2.
The low lubrication oil pressure defect in steam turbin set of a power plant has existed since the fluid coupling motor-driven feedwater pump was put into service.
某厂汽轮机组所配备的液力耦合电动给水泵组自投运以来一直存在润滑油压偏低的现象,经过多年的技术攻关,彻底解决了该泵组一直在低油压运行的重大隐患。
3.
Based on characteristics of motor-driven feedwater pump of supercritical units,the paper discusses the configuration mode and its function,capacity and initial investment for motor-driven feedwater pump of 2×660MW supercritical units of Yangxi Power Plant in Guangdong Huanxia,and it can give supplier a theoretic basis for final decision-making.
根据超临界机组电动给水泵的特点,对广东华厦阳西电厂2×660MW超临界机组电动给水泵的配置方式从功能、容量及设备初投资等方面进行比较论述,为业主的最终决策提供理论依据。
4) motor-drive FW pump
电动给水泵
1.
The feasibility study of the alteration of variable frequency speed regulation motor-drive FW pump is expatiated,and the integrated technological and economic comparison is introduced.
对200MW汽轮机组高压锅炉电动给水泵变频调速进行了综合技术经济比较。
5) motor-driven pump
电动给水泵
1.
Taking economy estimation of military electric power 200 MW unit all capacity motor-driven pump changed to steam feed pump as an example to analyse methods of energy saving.
以军粮城发电厂200 MW机组配套2台液力耦合器驱动的全容量电动给水泵为例,论证如从汽机本体四抽抽出部分蒸汽驱动小汽轮机,以小汽轮机驱动给水泵来代替电机驱动,可节约厂用耗电。
6) steam feed pump
汽动给水泵
1.
A 50% capacity steam feed pump encountered serious vibration at its suction side when put into service at low-load period.
华能福州电厂一台50%容量汽动给水泵在低负荷启动并入系统时,因即将退出的电泵出口调门内漏较大引起给水系统振荡,导致泵吸入侧强烈振动,又因轴振信号呆滞,未能准确判断而多次解体检查,延误主机满负荷运行,对振动进行了分析并处理,取得了良好的效果。
2.
In order to improve the unit s economy,safety and stability,the reform of electrical speed regulation water-feeding pump into steam feed pump of four 220 MW units is carried out in Xuzhou Power Generation Co.
为提高机组经济性与安全稳定性,对江苏徐州发电有限公司4台220MW机组进行了电动调速给水泵改汽动给水泵工作。
3.
This paper analyzes the fault occurred in the aspects of protection,sealing and steam source during the operation of steam feed pump equipped on 300 MW turbogenerator.
对300 MW汽轮发电机组所配汽动给水泵在实际运行过程中保护、密封、汽源等环节出现的故障进行了分析,提出的解决办法和改进措施有效地解决了汽动给水泵运行中频繁跳闸的问题,提高了锅炉给水系统的可靠性。
补充资料:给水泵起停控制
给水泵起停控制
boiler feed-water pump start-up and shutdown control
给水泵起、停控制一般都采用顺序控制系统,其控制对象包括给水泵电动机、辅助油泵、泵出口阀门和再循环阀门。 在停止水泵时,应先将水泵的转速降到最低值后再停止水泵的电动机,这样做的目的是当再次起动水泵时,可以保证电动机在低负载下起动。水泵起动后,需要保持一定流量的给水以冷却泵体,因此,在泵的出口阀门前设有再循环阀门,当泵的流量低于规定值时就要开启再循环阀门,使泵有足够的流t,一般情况下,再循环阀门的动作值是泵最大流量的30%.为了避免在起动时电动机过载,要求水泵在空载条件下起动,也就是当水泵出口母管压力等于零的情况下起动水泵时,应先将泵出口阀门关闭后再起动,而在其他情况下起动水泵时,不论是泵的切换或备用泵自起动,由于水泵出口母管压力已经建立,为了缩短水泵的起动时间以适应尽快带负载的要求,应在泵出口阀门开启情况下起动水泵,而泵的出口逆止阀在泵起动前处于关闭位置,可以保证泵可靠的隔离。在电动机的轴上带有一台主油泵,在电动机运行时.供液力联轴器和各个轴承的润滑用油.在泵起动和停止过程中必须起动辅助油泵。 给水泵顺序控制系统就是按上述运行方式对给水泵起、停全过程进行控制的.控制装里:对于小型给水泵,可采用继电器组件或小型可编程退抖控制器单独构成;而对于大型机组都归入分散拉制系统中的主、辅机顺序控制系统范围内。 对于汽动给水泵,有关其汽轮机的控制可参见给水泵汽轮机控制系统。j .Shu,beng ql ting kongZhl给水泵起停控制(boiler feed一water pumpstart一up and shut一down eontrol)电动给水泵的容量大、压力高、一般配有液力联轴器或变频调速器调速,因此在结构上和运行方式上都有着自己的特点。