1) resonant grounded
谐振接地的
2) resonant grounded
谐振接地
1.
Theory and characteristic of three kinds of grounded modes including ungrounded,grounded through a small resistance,resonant grounded are presented.
首先介绍了配电网的3种接地方式(不接地、经电阻接地、谐振接地)的原理和特点,然后利用MAT LAB仿真平台,对某10kV配电网的这三种接地方式进行了仿真比较,针对该配电网的输电线单相接地问题给出了较为准确的数值仿真解,指出了中性点经消弧线圈接地方式是目前比较合理的接地方式。
3) Resonance grounding
谐振接地
1.
Application of signal injection method for fault line selection and fault point location in resonance grounding system;
“S注入法”选线定位原理在谐振接地电网中的应用
2.
Power system resonance grounding and ground fault neutralizer;
电力系统谐振接地及接地电流自动补偿装置
3.
The paper introduced the 4 kinds of line selection principle that applies to the resonance grounding system,in which the small disturbance method and shunt resistance method were compared from the aspects such as line selection principle,measures for line selection accuracy,fast and successive line selection ability,increase quantity and duration of residual current and safety.
文章介绍了适用于谐振接地系统的四种主要选线原理,对其中应用最广的小扰动法和并联电阻法选线方式从选线原理、选线准确性保障措施、快速与连续选线能力、残流增大量与持续时间、安全性等各方面进行了比较。
4) resonant grounding
谐振接地
1.
The resonant grounding and low resistance grounding on the 10kV distribution system neutral grounding is discussed in the paper.
对10kV配电网中性点谐振接地方式与低电阻接地方式,进行了分析,理论研究和实践经验表明,谐振接地方式符合10kV配电网发展的需要并可以作为10kV配电网与发电厂解决10kV母线问题的借鉴。
5) resonant grounded system
谐振接地
1.
Nowadays, more and more MV systems become resonant grounded system to suppress grounded arcs.
目前,越来越多的中压电网采用谐振接地方式以更加有效地熄灭接地电弧,采用这种接地方式的关键技术是消弧线圈补偿方式和消弧线圈的选择。
6) resonance ground
谐振接地
1.
This paper has carried on deep analysis and studies to various kinds of capacitive current calculation methods of resonance ground system and compensation principles of arc-suppressing coil, and has pointed out the error that they exist in theory and the necessity of reducing the error.
本文对谐振接地系统的多种电容电流计算方法和消弧线圈补偿原理进行了深入的分析与研究,指出了它们在理论上存在的误差及减小误差的必要性。
2.
Resonance grounding system is an important ground style of medium voltage network.
谐振接地是我国中压电网接地方式中一种主要的接地方式,对于改善供电质量、提高供电可靠性、消除系统铁磁谐振、限制单相接地故障残流等方面有很好的效果,因此其对系统的安全运行有着十分重要的意义。
补充资料:电力系统中性点接地变压器接地
电力系统中性点接地变压器接地
earthing transformer for neutral grounding
d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条