1) load transfer switch
负荷切换开关
2) load switching
负荷切换
1.
An approach to several problems about the driving turbine of feedwater pumps, such as steam admission mode, lubricating oil and gland seal systems, as well as load switching etc.
对300MW机组给水泵汽轮机的进汽方式、润滑油和轴封系统及负荷切换进行了探讨,对它们之间的关系进行了分析。
3) load-break switch
负荷开关
1.
In recent years, since the load-break switch/fuse general integrated switchgear is simple in structure, convenient for maintenance, low in cost and reliable in operation compared with circuit breaker, so it is selected and widely employed for the selection of protection and control switch for 10 kV power transformer.
近年来,在10kV配电变压器保护和控制开关的选用中,由于负荷开关-熔断器组合电器与断路器相比具有结构简单、操作维护方便、造价低、运行可靠等优点,使之获得广泛的应用。
2.
Introduces the load-break switch monitor system of OCS in Liupanshui railway conjunction, offers methods and precautions for its installation and commissioning.
介绍了内昆线六盘水枢纽接触网负荷开关监控系统,并结合该系统给出了其安装调试的方法及注意要点。
4) load switch
负荷开关
1.
Discussion about the choice of 10kV breaker and load switch in distribution system;
配电网10kV断路器与负荷开关选择之探讨
2.
Analysis of transfer current when breaking circuit by high-voltage current-limiting fuse and box-load switch;
高压限流熔断器—负荷开关开断电路时转移电流的分析
3.
There are 3 kinds of breakers at the generator outlet, including the load switch to cut off the load current, circuit breaker with limited breaking capacity and circuit breaker with full breaking capacity.
发电机出口断开装置 ,分为仅能开断负荷电流的负荷开关、具有有限开断容量的断路器和具有全开断容量的断路器 3种。
5) switch
[英][swɪtʃ] [美][swɪtʃ]
负荷开关
1.
In this paper, the fault mechanism of the test duty 6a and 6b in accordance with GB3804-2004 is analyzed and the operating condition of the switch during opening period is presented.
分析了GB3804-2004试验方式6a和6b所对应的故障机理,提出了负荷开关开断过程的运行工况,讨论了如何确定两种试验方式的参数。
2.
Technical discussions on the functions and the selection of switch-fuse combination used in 10 kV distribution units are given.
分析探讨了10 kV配电系统中负荷开关-熔断器保护的主要作用和原理。
3.
Technical discussions on the function and the selection of switch-fuse combination used in 12 kV ring main units are given in the paper.
就12kV环网系统中负荷开关-熔断器保护的主要作用机理和选用问题进行了分析探讨。
6) high voltage load disconnecting switch
高压负荷切断开关
补充资料:备用电源自动切换装置
备用电源自动切换装置
automatic transfer to stand-by supply
be(yongd旧nyt一anz一dongq旧hoon zhuongzhl备用电派自动切换装t(automati。transferto stand一by supply)当工作电源消失或当工作电压降低过多时.能将备用电源断路器快速合闸向负载恢复供电的自动切换装置。 自动切换的一次系统常用的设自动切换装置的一次系统接线有以下两种:①两个电源(两台变压器或两条线路)互为备用。正常运行时,两个电源分别工作,电源之间设有经常断开的自动切换断路器,当其中一个电源故障时,另一个电源通过切换断路器迅速投人而恢复运行。这种自动切换方式通常称为暗备用。两个电源需具有充分的容量,以便在故障情况下由同一个电源向两个负荷供电。②利用一个备用电源作多个工作电源的备用.当一个工作电源故障退出运行时,备用电源自动投人,这种方式通常称为明备用。 自动切换装里功能切换装置的接线具有以下基本功能:①当工作电源消失时,快速起动自动切换装里,投人备用电源;②当工作电源母线电压降低,由接在母线上的低电压继电器动作,进行切换;③备用电源自动投人装置只能动作一次;④工作电源母线故障时,备用电源不允许投人。 火力发电厂备用电源自动切换接线,常用的有慢速切换和快速切换两种方式。 慢速切换为工作电源断路器断开后,经延时,当电动机残压下降到电动机允许的安全电压后才实现自动切换。当工作电源侧断路器跳闸时,联动受电侧断路器跳闸,以起动备用电源自动投人装置。同时,在工作母线上装设单独的低电压起动装置,当工作电源电压降到安全值,即20%~30%额定电压以下,而备用电源母线上保持一定电压值时,使备用电源断路器合闸。慢速切换时间一般为0.5一1·5s。 快速切换装置主要用于300 MW及以上容量的发电机,这种切换方式对电动机的冲击及对机组热力系统的正常运行影响较小,切换过程平衡。实现快速切换的条件是工作和备用电源断路器必须快速动作,要求合闸及跳闸时间为0.06~0.085。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条