说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 换热面积,加热面积,传热面积
1)  heating surface area
换热面积,加热面积,传热面积
2)  heat transfer area
换热面,传热面[积]
3)  heat-exchanging area
换热面积
1.
Introduced in the article are the main aspects of the positive water evaporator, including the operating principle,the structural characteristics,the method for calculation of the heat-exchanging area as well as its superiorities and main advantages.
介绍了容积式水蒸发器的原理,简述结构特点及计算容积式蒸发器换热面积,阐明其优越性和突出优点。
4)  Heat exchanging area
换热面积
1.
Fouling mechanism of cooler is analyzed,and regulation of fouling products and fouling resistance of cooler with the running period,the relate formula among the fouling resistance,heat exchanging coefficient and heat exchanging area are given.
分析了冷却器的结垢机理 ,提出了冷却器污垢层、污垢热阻随运行时间的规律 ,以及污垢热阻与换热系数、换热面积的关系式 ,并通过算例阐述了污垢热阻对冷却器的影响程度 ,进而定性地分析了污垢热阻对空分装置的影响。
5)  Heat Transfer Area
换热面积
1.
Presents types of the high temperature heat pump system and the preliminary design of the heat exchanger, and programs for the system simulation, and obtains the variety patterns of several critical parameters including COP, heat transfer coefficient, water pressure drop with heat transfer area under eight different heat exchanger types.
介绍了高温热泵系统形式及换热器初步设计,编制了系统仿真程序,得到了8种换热器型号下系统COP、换热器传热系数、水侧压降等关键参数随换热面积的变化关系。
2.
It is illustrated that increasing the heat transfer coefficient and minimizing the heat transfer area is the ultimate objective for the process design of condensers.
综述了管壳式冷凝器的流体力学基础和工艺设计参数的选择 ,介绍了冷凝器材质和换热介质及走向的选择 ;阐明了提高传热系数、降低换热面积是冷凝器工艺设计的最终目标 ;结合某工程项目 ,运用HTFS软件进行计算选型 ,生产结果表明选用效果良好。
3.
The heat exchanger volume was considered as the optimization objective function; the heat transfer area required for the heat duty and the pressure drop were considered as the restrictive conditions.
把体积作为优化目标函数,以换热面积和压降作为约束条件,对管子横向间距、纵向间距、管排数、外翅片间距、换热器在与热气流垂直方向的长度进行了优化,并与利用遗传算法的文献结果对比:在相同的设计参数和相同的优化变量搜索范围条件下,体积减小9。
6)  heat exchange area
换热面积
1.
Optimal design for dual-stage high temperature heat pump by heat exchange area simulation;
双级循环高温热泵换热面积仿真优化设计方法
2.
In order to keep the equipment running, process operation adjustment and extensive pipeline repair were conducted, and ultimately reduced the heat exchange area and change .
为了解决低变106DC频繁泄漏的问题,对其失效原因进行了应力核算和综合分析,分析106DC失效的主要原因是:换热面积设计过大;换热管与壳体材料线膨胀系数差别大换热管压应力较高。
补充资料:换热
      指冷热两流体间所进行的热量传递,是一种属于传热过程的单元操作。换热的目的主要有:①物料的加热、冷却、汽化或冷凝,以达到或保持生产工艺所要求的温度或相态;②热量的综合利用,用待冷却的热流体向待 加热的冷流体供热,以提高热量利用率。换热操作广泛应用于各工程领域,与化学工业的关系尤为密切。在化工生产中,换热在两种流体物料间进行,或在流体物料与载热体间进行。载热体是一类专门用来接受或提供热量的流体,最常用的载热体有蒸汽、水和空气。冷热两流体间的换热通常在换热器中进行。按冷热流体的接触传热方式,换热器分为间壁式、接触式和蓄热式,尤以间壁式换热器的应用最广。
  
  换热计算的重点是间壁式换热器的计算。或已知待冷却的热流体质量流量为,温度为T1,要求冷却后温度为T2,则所需换热面积的计算步骤为:①计算热流量:
  
  
  
     式中为热流体的比热容;②选择冷却剂及其进出口温度t2和t1,由热量衡算计算出冷却剂的质量流量:
  
  
  
  
  
  
  式中为冷却剂的比热容;③选定冷热流体的流动条件,计算或测定传热分系数及传热系数K;④由冷热两流体的进出口温度及选定的两流体的流动方式,计算平均温度差 Δtm;⑥根据传热基本方程式(见传热过程)算出传热面积:
  
  
  
  
  
  A=Q/(KΔtm)
  
  进行上述计算时,须作出若干选择,而不同的选择会得出不同的结果。设计者须对多种方案进行比较,从中选出一个经济上合理、技术上可行的方案。此外,若换热器对流体的流动阻力有限制,可从流速选择和换热器结构等方面予以调整。
  
  还可用传热单元数法进行换热计算。这种方法用于原有换热器的传热性能核算更为方便。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条