1) direct current
直流[电],直流
2) direct current
直流电流
1.
Solidification behavior of alloy ZA27 under action of direct current;
ZA27合金在直流电流作用下的凝固行为
2.
Analysis on the causes of direct current fluctuation in rectifying system and the solutions;
整流系统直流电流波动原因分析及解决方案
3.
The influences of direct current density,heating temperature,and holding time on the microstructure evolution of magnesium alloy AZ91D during semi-solid isothermal heat treatment were studied,and the related mechanism was also discussed.
考察了直流电流密度、等温温度及等温时间对 AZ91D 镁合金半固态组织的影响,对电流影响组织演变的机理进行了探讨。
4) DC current
直流电流
1.
The calculation results of DC currents through transformer neutrals of HVDC system operated in monopole-ground return mode with the influence of sea considered are evidently different from those calculated by terrestrial soil model.
考虑海洋影响的直流输电单极大地运行时变压器中性点流过的直流电流与陆地土壤模型计算的结果有很大不同。
2.
The DC current through transformer neutrals may make the transformers DC biases.
结合岭澳和大亚湾核电站主变的具体情况,按实测的流过主变中性点直流电流结果建立了相应的大地电网计算模型,并对在变压器中性点串联电容的方法进行了深入的分析,还根据分析结果提出了有关设备的主要技术参数。
3.
But the AC and DC transmission system brings DC current in neuter spot of transformer,it will affect the natural running of transformer and whole power system, and the effect to transfomer is different with different configuration,so it is necessary to messure and restrain the DC current in neuter spot of transformer.
但是,交、直流混合输电系统会在交流变压器中性点产生直流电流,造成变压器绕组直流偏磁影响变压器和整个系统的正常运行,并对不同结构变压器产生影响的程度也不尽相同,因此,必须对变压器中性点直流电流进行有效的检测和抑制。
5) direct current consumption
直流电耗
1.
Brief analysis on influential factors of direct current consumption in ionic membrane caustic soda production;
浅析离子膜法烧碱直流电耗的影响因素
2.
Strengthening management and control is put forward in order to increase the current efficiency and decrease direct current consumption in diaphragm caustic soda production.
提出加强管理和控制,提高隔膜法烧碱生产中的电流效率,降低直流电耗。
3.
Various factors of influencing direct current consumption duringNielectrowinning(using)insoluble anode have been analysed.
对影响不溶阳极电积镍直流电耗的各种因素进行了分析,降低溶液电阻、减少线路损耗可降低槽电压,而稳定阴极液pH、适当提高溶液中镍离子和H3BO3浓度对提高电流效率、降低直流电耗有利,采取相应措施后,取得了良好效果,直流电耗降低了5%,经济效益明显。
6) direct current electrolysis
直流电解
1.
Researches on the application of direct current electrolysis disinfection for purified drinking water;
饮用净水的直流电解消毒应用研究
补充资料:直流电流互感器
用于直流电流量值变换的互感器。它利用铁心线圈中铁心受直流和交流电流共同磁化时的非线性和非对称性,通过整流电路,将通过线圈的直流大电流按匝数反比变换成直流小电流。主要用于测量直流大电流,也在整流系统中用作电流反馈、控制和保护元件。与分流器(见电流表)比较,它的电能损耗低并具有隔离作用。常用的直流电流互感器的线路如图。图中A与B是两个相同但各自独立的铁心。直流大电流I1流过两个初级绕组(即图中的穿通导线,相当于初级N1=1匝),两铁心上的次级绕组均为N2匝,以相反极性串接,由正弦波交流电源供电。随着电源电压极性交替变换,两铁心将轮流处于深饱和与非饱和状态。在理想条件下,电源电压U与负载电阻Rx上电压之差,由非饱和铁心上的次级绕组承担,并有N1I1=N2I2或I1/I2=N2/N1(I2为次级电流),即I2和I2与匝数有反比关系。I2经整流后,可用直流电流表读出,或利用负载电阻Rx上的电压降计算出。
20世纪30年代后,由于用了附加的补偿绕组,使直流电流互感器的准确度提高到 0.1级。随着电子器件的发展,利用铁心磁通中的偶次谐波分量,经过放大、反馈形成自动补偿式的零磁通直流互感器,其误差低于0.01%。
20世纪30年代后,由于用了附加的补偿绕组,使直流电流互感器的准确度提高到 0.1级。随着电子器件的发展,利用铁心磁通中的偶次谐波分量,经过放大、反馈形成自动补偿式的零磁通直流互感器,其误差低于0.01%。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条